Directional sinogram interpolation for motion weighted 4D cone-beam CT reconstruction

被引:11
|
作者
Zhang, Hua [1 ]
Kruis, Matthijs [1 ]
Sonke, Jan-Jakob [1 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Plesmanlaan 121, NL-1066 CX Amsterdam, Netherlands
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 06期
关键词
4D cone-beam CT; directional interpolation; image quality; DEFORMABLE REGISTRATION; COMPUTED-TOMOGRAPHY; STRATEGIES; ARTIFACTS;
D O I
10.1088/1361-6560/aa5b6e
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The image quality of respiratory sorted four-dimensional (4D) cone-beam (CB) computed tomography (CT) is often limited by streak artifacts due to insufficient projections. A motion weighted reconstruction (MWR) method is proposed to decrease streak artifacts and improve image quality. Firstly, respiratory correlated CBCT projections were interpolated by directional sinogram interpolation (DSI) to generate additional CB projections for each phase and subsequently reconstructed. Secondly, local motion was estimated by deformable image registration of the interpolated 4D CBCT. Thirdly, a regular 3D FDK CBCT was reconstructed from the non-interpolated projections. Finally, weights were assigned to each voxel, based on the local motion, and then were used to combine the 3D FDK CBCT and interpolated 4D CBCT to generate the final 4D image. MWR method was compared with regular 4D CBCT scans as well as McKinnon and Bates (MKB) based reconstructions. Comparisons were made in terms of (1) comparing the steepness of an extracted profile from the boundary of the region-of-interest (ROI), (2) contrast-to-noise ratio (CNR) inside certain ROIs, and (3) the root-mean- square-error (RMSE) between the planning CT and CBCT inside a homogeneous moving region. Comparisons were made for both a phantom and four patient scans. In a 4D phantom, RMSE were reduced by 24.7% and 38.7% for MKB and MWR respectively, compared to conventional 4D CBCT. Meanwhile, interpolation induced blur was minimal in static regions for MWR based reconstructions. In regions with considerable respiratory motion, image blur using MWR is less than the MKB and 3D Feldkamp (FDK) methods. In the lung cancer patients, average CNRs of MKB, DSI and MWR improved by a factor 1.7, 2.8 and 3.5 respectively relative to 4D FDK. MWR effectively reduces RMSE in 4D cone-beam CT and improves the image quality in both the static and respiratory moving regions compared to 4D FDK and MKB methods.
引用
收藏
页码:2254 / 2275
页数:22
相关论文
共 50 条
  • [1] Directional Interpolation for Motion Weighted 4D Cone-Beam CT Reconstruction
    Zhang, Hua
    Sonke, Jan-Jakob
    [J]. MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT I, 2012, 7510 : 181 - 188
  • [2] Directional interpolation of sparsely sampled cone-beam CT sinogram data
    Bertram, M
    Rose, G
    Schäfer, D
    Wiegert, J
    Aach, T
    [J]. 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 and 2, 2004, : 928 - 931
  • [3] Motion compensation for cone-beam CT based on 4D motion field of sinogram tracked markers
    Schäfer, D
    Bertram, M
    Conrads, N
    Wiegert, J
    Rose, G
    Rasche, V
    [J]. CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 189 - 194
  • [4] Simultaneous motion estimation and image reconstruction (SMEIR) for 4D cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL PHYSICS, 2013, 40 (10)
  • [5] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [6] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-Beam CT
    Wang, J.
    Gu, X.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for 4D Cone-beam CT
    Wang, Jing
    Gu, Xuejun
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [8] 4D Cone-beam CT reconstruction using a motion model based on principal component analysis
    Staub, David
    Docef, Alen
    Brock, Robert S.
    Vaman, Constantin
    Murphy, Martin J.
    [J]. MEDICAL PHYSICS, 2011, 38 (12) : 6697 - 6709
  • [9] Directional sinogram interpolation for sparse angular acquisition in cone-beam computed tomography
    Zhang, Hua
    Sonke, Jan-Jakob
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2013, 21 (04) : 481 - 496
  • [10] 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT
    Gao, Y.
    Thomas, D.
    Low, D.
    Gao, H.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 117 - 117