Magnetic resonance cisternography and thin coronal computerized tomography in the evaluation of cerebrospinal fluid rhinorrhea

被引:43
|
作者
Sillers, MJ [1 ]
Morgan, CE [1 ]
ElGammal, T [1 ]
机构
[1] UNIV ALABAMA, DEPT SURG, DIV OTOLARYNGOL HEAD NECK SURG, BIRMINGHAM, AL 35233 USA
来源
AMERICAN JOURNAL OF RHINOLOGY | 1997年 / 11卷 / 05期
关键词
D O I
10.2500/105065897781286052
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
In recent years cerebrospinal fluid (CSF) rhinorrhea has been managed successfully with transnasal endoscopic techniques. The most important and often most difficult step is the precise localization of the fistula. Computerized tomographic and radionuclide cisternography are two commonly used techniques for preoperative identification of the CSF fistula when it cannot be seen clearly with nasal endoscopy. Each of these requires a lumbar puncture, and the intrathecal placement of contrast material has been associated with transient neurotoxicities. Magnetic resonance cisternography (MRC) is a noncontrast study that does not require a lumbar puncture and has been used recently in the diagnosis of spontaneous and traumatic CSF leaks. Magnetic resonance cisternography utilizes a fast spin-echo sequence with fat suppression and video image reversal that highlights CSF. This allows precise localization of the fistula in both coronal and sagittal planes. Thin section coronal computed tomography (TCCT) is another noninvasive technique that can be helpful in localizing CSF leaks. The technique of MRC and TCCT and the results of 16 CSF leaks in 15 patients are reported. There was good correlation between MRC, TCCT, and intraoperative findings. Magnetic resonance cisternography and thin coronal computerized tomography appear to be accurate and complementary, noninvasive radiographic studies that should be considered in the evaluation CSF rhinorrhea.
引用
收藏
页码:387 / 392
页数:6
相关论文
共 50 条
  • [41] Evaluation of renal growth by magnetic resonance imaging and computerized tomography volumes
    Heuer, R
    Sommer, G
    Shortliffe, LD
    JOURNAL OF UROLOGY, 2003, 170 (04): : 1659 - 1663
  • [42] Spontaneous cerebrospinal fluid rhinorrhoea: computed tomography and magnetic resonance imaging findings
    Choong, Chih Ching
    Venkatesh, Sudhakar Kundapur
    Phadke, Rajendra Vishnu
    SINGAPORE MEDICAL JOURNAL, 2013, 54 (03) : 176 - 181
  • [43] Supplementary comment on "Computed tomography evaluation of air cells in the Petrous bone - Relationship with postoperative cerebrospinal fluid rhinorrhea"
    Bulsara, KR
    Al-Mefty, O
    NEUROLOGIA MEDICO-CHIRURGICA, 2003, 43 (09) : 469 - 469
  • [44] Utility of computed tomography or magnetic resonance imaging evaluation of ventricular morphology in suspected cerebrospinal fluid shunt malfunction
    Sellin, Jonathan N.
    Cherian, Jacob
    Barry, James M.
    Ryan, Sheila L.
    Luerssen, Thomas G.
    Jea, Andrew
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2014, 14 (02) : 160 - 166
  • [45] Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts
    M. Awaji
    K. Okamoto
    K. Nishiyama
    Neuroradiology, 2007, 49 : 721 - 726
  • [46] Magnetic resonance cisternography for preoperative evaluation of arachnoid cysts
    Awaji, M.
    Okamoto, K.
    Nishiyama, K.
    NEURORADIOLOGY, 2007, 49 (09) : 721 - 726
  • [47] Magnetic resonance cisternography in the diagnosis of delayed iatrogenic cerebrospinal fistula: A case report
    Geyer, JD
    Nabors, LB
    Harrell, LE
    Gomez, CR
    JOURNAL OF NEUROIMAGING, 1997, 7 (04) : 244 - 247
  • [48] CEREBROSPINAL-FLUID RHINORRHEA - LOCALIZATION OF DURAL FISTULAS USING METRIZAMIDE, HYPOCYCLOIDAL TOMOGRAPHY AND COMPUTED-TOMOGRAPHY
    DOHRMANN, GJ
    PATRONAS, NJ
    DUDA, EE
    MULLAN, S
    SURGICAL NEUROLOGY, 1979, 11 (05): : 373 - 377
  • [49] COMPARISON OF CEREBROSPINAL-FLUID DYNAMICS STUDIED BY COMPUTED TOMOGRAPHY (CT) AND RADIOISOTOPE (RI) CISTERNOGRAPHY
    TAMAKI, N
    KANAZAWA, Y
    ASADA, M
    KUSUNOKI, T
    MATSUMOTO, S
    NEURORADIOLOGY, 1978, 16 : 193 - 198
  • [50] Evaluation of Band Generation Process for classification of cerebrospinal fluid in Magnetic Resonance Images
    Lee, Kuan-Ru
    Wu, Chao-Cheng
    Chiang, Yung-Hsiao
    Lin, Jiannher
    2016 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2016, : 4305 - 4310