Optimal Implantable Cardioverter Defibrillator (ICD) Generator Replacement

被引:6
|
作者
Khojandi, Anahita [1 ]
Maillart, Lisa M. [1 ]
Prokopyev, Oleg A. [1 ]
Roberts, Mark S. [2 ]
Brown, Timothy [3 ]
Barrington, William W. [4 ]
机构
[1] Univ Pittsburgh, Dept Ind Engn, Pittsburgh, PA 15261 USA
[2] Univ Pittsburgh, Dept Hlth Policy & Management, Pittsburgh, PA 15261 USA
[3] Medtronic, Minneapolis, MN 55432 USA
[4] Univ Pittsburgh, Med Ctr, Inst Heart & Vasc, Pittsburgh, PA 15213 USA
基金
美国国家科学基金会;
关键词
optimal replacement; Markov decision processes; threshold policy; CUMULATIVE DAMAGE MODELS; FOLLOW-UP; DEVICE ADVISORIES; CLINICAL-PRACTICE; RISK-FACTORS; LONGEVITY; INFECTIONS; PACEMAKERS; INSIGHTS; DATABASE;
D O I
10.1287/ijoc.2013.0586
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Implantable cardioverter defibrillators ( ICDs) include small, battery-powered generators, the longevity of which depends on a patient's rate of consumption. Generator replacement, however, involves risks, including death. Hence, a trade-off exists between prematurely exposing the patient to these risks and allowing for the possibility that the device is unable to deliver therapy when needed. Currently, replacements are performed using a one-size-fits-all approach. Here, we develop a Markov decision process model to determine patient-specific optimal replacement policies as a function of patient age and the remaining battery capacity. We analytically establish that the optimal policy is of threshold-type in the remaining capacity, but not necessarily in patient age. Based on clinical data, we conduct a large computational study that suggests that under the optimal policy, patients undergoing initial implantation at age 30-40, 41-60, and 61-80 see an approximate decrease in the total expected number of replacements of 8%-14%, 8%-15% and 8%-19%, respectively, while achieving the same or greater expected lifetime.
引用
收藏
页码:599 / 615
页数:17
相关论文
共 50 条
  • [21] Optimal Implantable Cardioverter Defibrillator Programming
    Shah, Bindi K.
    CARDIOLOGY IN REVIEW, 2017, 25 (01) : 30 - 35
  • [22] SUBFASCIAL IMPLANTATION OF IMPLANTABLE CARDIOVERTER DEFIBRILLATOR GENERATOR
    SHAHIAN, DM
    WILLIAMSON, WA
    STREITZ, JM
    VENDITTI, FJ
    ANNALS OF THORACIC SURGERY, 1992, 54 (01): : 173 - 174
  • [23] Indications for an implantable cardioverter/defibrillator [Indikationen für den implantierbaren cardioverter/defibrillator (ICD)]
    Schwab J.O.
    Lüderitz B.
    Der Internist, 2007, 48 (7): : 715 - 726
  • [24] Restratification at Time of Implantable Cardioverter Defibrillator Replacement
    Cygankiewicz, Iwona
    Ptaszynski, Pawel
    REVISTA ESPANOLA DE CARDIOLOGIA, 2014, 67 (12): : 971 - 973
  • [25] Implantable Cardioverter Defibrillator Generator Replacement and Breast Implant Revision-A Combined Case
    Lamprou, Vasileios
    Murphy, John
    Ardizzone, Andrea
    Campbell, Niall G.
    CLINICAL CASE REPORTS, 2025, 13 (02):
  • [26] Resolution of T-wave oversensing with implantable cardioverter defibrillator generator replacement in an adolescent
    Tuzcu, Volkan
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2007, 30 (07): : 929 - 932
  • [27] Evaluation of the Need of Elective Implantable Cardioverter-Defibrillator Generator Replacement in Primary Prevention Patients Without Prior Appropriate ICD Therapy
    Yap, Sing-Chien
    Schaer, Beat A.
    Bhagwandien, Rohit E.
    Kuhne, Michael S.
    Abkenari, Lara Dabiri
    Osswald, Stefan
    Szili-Torok, Tamas
    Sticherling, Christian
    Theuns, Dominic A.
    CIRCULATION, 2013, 128 (22)
  • [28] Outcomes following implantable cardioverter-defibrillator generator replacement in adults: A systematic review
    McCarthy, Killian J.
    Locke, Andrew H.
    Coletti, Margo
    Young, Diane
    Merchant, Faisal M.
    Kramer, Daniel B.
    HEART RHYTHM, 2020, 17 (06) : 1036 - 1042
  • [29] Evaluation of the need of elective implantable cardioverter-defibrillator generator replacement in primary prevention patients without prior appropriate ICD therapy
    Yap, Sing-Chien
    Schaer, Beat A.
    Bhagwandien, Rohit E.
    Kuehne, Michael
    Abkenari, Lara Dabiri
    Osswald, Stefan
    Szili-Torok, Tamas
    Sticherling, Christian
    Theuns, Dominic A. M. J.
    HEART, 2014, 100 (15) : 1188 - U95
  • [30] RISK FACTORS FOR VENTRICULAR TACHYARRHYTHMIA FOLLOWING ELECTIVE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR GENERATOR REPLACEMENT
    Goldenberg, Ido
    Buttar, Rupinder
    Sherazi, Saadia
    Shah, Abrar H.
    Aktas, Mehmet K.
    Hall, Burr W.
    Chuprun, Dmitry
    Taylor, Sarah
    Rosero, Spencer
    Goldenberg, Ilan
    Karki, Roshan
    Rao, Mohan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 253 - 253