Cross-Calibration of Terra and Aqua MODIS Using RadCalNet

被引:6
|
作者
Angal, Amit [1 ]
Xiong, Xiaoxiong [2 ]
Thome, Kurtis [2 ]
Wenny, Brian N. [3 ]
机构
[1] Sci Syst & Applicat Inc, MCST, Lanham, MD 20706 USA
[2] NASA Goddard Space Flight Ctr GSFC, Greenbelt, MD 20771 USA
[3] Sci Syst & Applicat, Lanham, MD 20706 USA
关键词
MODIS; Atmospheric measurements; Calibration; Earth; Sea measurements; Extraterrestrial measurements; Aqua; moderate resolution imaging spectroradiometer (MODIS); RadCalNet; Railroad Valley (RRV); US (RVUS); terra; vicarious calibration;
D O I
10.1109/LGRS.2020.2973535
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Moderate Resolution Imaging Spectroradiometer (MODIS) instruments onboard the Terra and Aqua spacecraft have been successfully operating for nearly two decades and providing complementary observations of the Earth's land, ocean, and atmosphere. Although the two MODIS instruments view the entire Earth's surface once every 2-3 days, simultaneous views between them are limited due to their varying orbits. Therefore, the intercomparison between these two instruments has been previously performed using a transfer instrument [such as Advanced Very-high-resolution Radiometer (AVHRR)] or using lunar measurements normalized using a common model, such as the USGS Robotic Lunar Observatory (ROLO). In recent years RadCalNet, a Committee on Earth Observation Satellites (CEOS) initiative, has provided SI-traceable Top-of-Atmosphere (TOA) reflectances from a coordinated network of instrumented land-based sites. RadCalNet facilitates a unique mechanism to perform cross-calibration of instruments by minimizing the uncertainties associated with overpass time differences. In this letter, the near-simultaneous TOA reflectance measurements from the Railroad Valley (RRV), US (RVUS) are used as a transfer to compare the on-orbit observations for the Terra and Aqua MODIS reflective solar bands (RSBs). Near-nadir overpasses from January 2013 to January 2019 are processed and matched up with near-simultaneous RadCalNet measurements. Results show that the visible (VIS)/near-infrared response (NIR) bands agree to within 2%, and the short-wave infrared (SWIR) bands agree to within 5%. Also discussed in this letter are the future efforts that will be undertaken to expand this comparison to include other instruments, other sites, and both nadir- and off-nadir views after compensation for bidirectional reflectance distribution function (BRDF) effects.
引用
收藏
页码:188 / 192
页数:5
相关论文
共 50 条
  • [31] Intercomparison of Terra and Aqua MODIS using unscheduled lunar observations
    Angal, Amit
    Xiong, Xiaoxiong
    Wilson, Truman
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXII, 2018, 10785
  • [32] Cross-calibration of the reflective solar bands of Terra MODIS and Landsat 7 Enhanced Thematic Mapper Plus over PICS using different approaches
    Angal, Amit
    Brinkmann, Jake
    Mishra, Nischal
    Link, Daniel
    Xiong, Xiaoxiong
    Helder, Dennis
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XIX, 2015, 9639
  • [33] On-orbit Performance and Calibration Improvements for the Reflective Solar Bands of Terra and Aqua MODIS
    Angal, Amit
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chen, Hongda
    Geng, Xu
    Link, Daniel
    Li, Yonghong
    Wald, Andrew
    Brinkmann, Jake
    [J]. EARTH OBSERVING MISSIONS AND SENSORS: DEVELOPMENT, IMPLEMENTATION, AND CHARACTERIZATION IV, 2016, 9881
  • [34] Characterization of Terra and Aqua MODIS VIS, NIR, and SWIR Spectral Bands' Calibration Stability
    Wu, Aisheng
    Xiong, Xiaoxiong
    Doelling, David R.
    Morstad, Daniel
    Angal, Amit
    Bhatt, Rajendra
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2013, 51 (07): : 4330 - 4338
  • [35] On-orbit calibration and performance assessments of Terra and Aqua MODIS thermal emissive bands
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    Wilson, Truman
    Li, Yonghong
    Chen, Na
    Shrestha, Ashish
    Diaz, Carlos Perez
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2021, 15 (01)
  • [36] Lunar calibration improvements for the short-wave infrared bands in Aqua and Terra MODIS
    Wilson, Truman
    Angal, Amit
    Shrestha, Ashish
    Xiong, Xiaoxiong
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXI, 2017, 10423
  • [37] Assessment of the Collection 6 Terra and Aqua MODIS Bands 1 and 2 Calibration Performance
    Wu, A.
    Chen, X.
    Angal, A.
    Li, Y.
    Xiong, X.
    [J]. EARTH OBSERVING SYSTEMS XX, 2015, 9607
  • [38] Intercomparison of On-Orbit Calibration Consistency Between Terra and Aqua MODIS Reflective Solar Bands Using the Moon
    Xiong, Xiaoxiong
    Sun, Junqiang
    Barnes, William
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2008, 5 (04) : 778 - 782
  • [39] Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target
    Diaz, Carlos L. Perez
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [40] Calibration of the DSCOVR EPIC visible and NIR channels using MODIS Terra and Aqua data and EPIC lunar observations
    Geogdzhayev, Igor V.
    Marshak, Alexander
    [J]. ATMOSPHERIC MEASUREMENT TECHNIQUES, 2018, 11 (01) : 359 - 368