A ratiometric electrochemical sensor for multiplex detection of cancer biomarkers using bismuth as an internal reference and metal sulfide nanoparticles as signal tags

被引:29
|
作者
Yu, Lei [1 ,2 ]
Cui, Xin [2 ]
Li, Huijuan [3 ]
Lu, Jianjun [1 ]
Kang, Qi [1 ]
Shen, Dazhong [1 ]
机构
[1] Shandong Normal Univ, Coll Chem Chem Engn & Mat Sci, Collaborat Innovat Ctr Functionalized Probes Chem, Key Lab Mol & Nano Probes,Minist Educ, Jinan 250014, Shandong, Peoples R China
[2] Weifang Univ Sci & Technol, Shandong Peninsula Engn Res Ctr Comprehens Brine, Weifang 262700, Peoples R China
[3] Shandong Univ Sci & Technol, Coll Chem & Environm Engn, Qingdao 266590, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
GLASSY-CARBON ELECTRODE; STRIPPING VOLTAMMETRIC DETERMINATION; CARCINOEMBRYONIC ANTIGEN; FILM ELECTRODE; TUMOR-MARKERS; IMMUNOASSAY; AMPLIFICATION; IMMUNOSENSOR; SENSITIVITY; DOPAMINE;
D O I
10.1039/c9an00775j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ratiometric electrochemical sensors can provide a relatively accurate analysis of target analytes due to their self-calibration function. Herein, we report a simple ratiometric strategy for achieving the electrochemical detection of Cd(ii), Hg(ii), Pb(ii) and Zn(ii), as well as multiple cancer biomarkers by using metal sulfide nanoparticles as signal tags. A conductive polymer film of poly(2-amino terephthalic acid) (ATA) was electrochemically produced on a glassy carbon electrode (GCE) and doped with carbon nanotubes (CNTs) and mercaptosuccinic acid (MSA). Using Bi(iii) as an enhancer and internal reference in anodic stripping voltammetry, the MSA-CNT-ATA/GCE exhibited sensitive and distinguishable voltammetric responses to Cd(ii), Hg(ii), Pb(ii) and Zn(ii), with detection limits of 0.13, 0.49, 0.16 and 0.089 mu g L-1, respectively. By using CdS, HgS, PbS and ZnS labeled secondary antibodies as the signal tags, alpha-fetoprotein, carbohydrate antigen 19-9, carbohydrate antigen 125, and carcinoembryonic antigen were determined simultaneously according to the amounts of metal sulfide in the sandwich-type complexes, with detection limits of 0.11 pg mL(-1), 0.68 mU mL(-1), 1.4 mU mL(-1) and 0.23 pg mL(-1), respectively. This ratiometric approach has a wide scope in the electrochemical detection of heavy metal ions as well as immunoassays with metal ions serving as signal tags.
引用
收藏
页码:4073 / 4080
页数:8
相关论文
共 32 条
  • [21] Detection and quantification of lung cancer biomarkers by a micro-analytical device using a single metal oxide-based gas sensor
    Gregis, Geoffrey
    Sanchez, Jean-Baptiste
    Bezyerkhyy, Igor
    Weber, Guy
    Berger, Franck
    Fierro, Vanessa
    Bellat, Jean-Pierre
    Celzard, Alain
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 391 - 400
  • [22] Recent advances in design of electrochemical affinity biosensors for low level detection of cancer protein biomarkers using nanomaterial-assisted signal enhancement strategies
    Farzin, Leila
    Shamsipur, Mojtaba
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 147 : 185 - 210
  • [23] Ultrasensitive electrochemical aptasensor for ochratoxin A detection using AgPt bimetallic nanoparticles decorated iron-porphyrinic metal-organic framework for signal amplification
    Zhang, Jing
    Xu, Xiaojian
    Qiang, Yue
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 312
  • [24] An Ultrasensitive Electrochemical Aptasensor for Thrombin Detection Using MoS2 Nanoparticles Loaded Iron-Porphyrinic Metal-Organic Framework as Signal Amplifier
    Zhang, Jing
    Qiang, Yue
    Xu, Xiaojian
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2020, 167 (08)
  • [25] The High Stability and Selectivity of Electrochemical Sensor Using Low-Cost Diamond Nanoparticles for the Detection of Anti-Cancer Drug Flutamide in Environmental Samples
    Baskaran, Nareshkumar
    Prasanna, Sanjay Ballur
    Lin, Yu-Chien
    Duann, Yeh-Fang
    Chung, Ren-Jei
    Wei, Yang
    [J]. SENSORS, 2024, 24 (03)
  • [26] An electrochemical immunosensor for simultaneous multiplexed detection of two lung cancer biomarkers using Au nanoparticles coated resin microspheres composed of L-tryptophan and caffeic acid
    Wenbo Lu
    Lin Tao
    Ying Wang
    Xiaowei Cao
    Juan Ge
    Jian Dong
    Weiping Qian
    [J]. Ionics, 2015, 21 : 1141 - 1152
  • [27] An electrochemical immunosensor for simultaneous multiplexed detection of two lung cancer biomarkers using Au nanoparticles coated resin microspheres composed of L-tryptophan and caffeic acid
    Lu, Wenbo
    Tao, Lin
    Wang, Ying
    Cao, Xiaowei
    Ge, Juan
    Dong, Jian
    Qian, Weiping
    [J]. IONICS, 2015, 21 (04) : 1141 - 1152
  • [28] A label-free multiplex electrochemical biosensor for the detection of three breast cancer biomarker proteins employing dye/metal ion-loaded and antibody-conjugated polyethyleneimine-gold nanoparticles
    Kuntamung, Kulrisa
    Jakmunee, Jaroon
    Ounnunkad, Kontad
    [J]. JOURNAL OF MATERIALS CHEMISTRY B, 2021, 9 (33) : 6576 - 6585
  • [29] An electrochemical immunobiosensor for ultrasensitive detection of Escherichia coil O157:H7 using CdS quantum dots-encapsulated metal-organic frameworks as signal-amplifying tags
    Zhong, Miao
    Yang, Lu
    Yang, Hui
    Cheng, Chang
    Deng, Wenfang
    Tan, Yueming
    Xie, Qingji
    Yao, Shouzhuo
    [J]. BIOSENSORS & BIOELECTRONICS, 2019, 126 : 493 - 500
  • [30] A molecularly imprinted fluorescence sensor for sensitive detection of tetracycline using nitrogen-doped carbon dots-embedded zinc-based metal-organic frameworks as signal-amplifying tags
    Zhang, Jinni
    Li, Yan
    Teng, Longhao
    Cao, Yichuan
    Hu, Xuelian
    Fang, Guozhen
    Wang, Shuo
    [J]. ANALYTICA CHIMICA ACTA, 2023, 1251