Comparison of the fracture resistance of six denture base acrylic resins

被引:43
|
作者
Uzun, G
Hersek, N
机构
[1] Hacettepe Univ, Sch Dent Technol, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Dent, Dept Prosthodont, TR-06100 Ankara, Turkey
关键词
acrylic resins; denture base materials; mechanical properties;
D O I
10.1177/0885328202017001597
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Fracture strength of denture base resins is of great concern, and many approaches have been used to strengthen acrylic resin dentures. Fracture resistance of six commercially available acrylic resin denture base materials were compared, through impact and transverse strength tests. Three rapid heat-polymerised resins (QC 20, Meliodent and Trevalon), two high-impact strength resins (Trevalon Hi and Lucitone 199) and a strengthened injection-moulded acrylic resin (SR Ivocap plus) were included in the study. Twenty acrylic resin test specimens were fabricated from each resin. For impact strength test, ten notched specimens were tested in a Charpy-type impact tester. The other ten specimens were used for transverse strength tests, deflection and modulus of elasticity values were also determined, which were assessed with three-point bending tests using an Universal Testing Machine. Impact test values showed significant differences among acrylic resins (F = 4.817 p = 0.0). SR Ivocap resin showed the highest impact strength values, followed by Trevalon Hi and Lucitone 199. The transverse strength test values were not significant when six acrylic resins were compared (F = 1.705 p = 0.151). High-impact resins can be recommended to increase the impact strength of denture base. If the cause of fracture is mechanical or anatomical, strengthened acrylic resins and conventional acrylic resins have similar fracture resistance.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 50 条
  • [31] Color stability of denture base acrylic resins in three food colorants
    Hersek, N
    Canay, S
    Uzun, G
    Yildiz, G
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (04): : 375 - 379
  • [32] Mechanical properties of conventional versus microwavepolymerized denture base acrylic resins
    Mayall, Rebecca E.
    Selecman, Audrey M.
    Morrow, Brian R.
    Gullard, Angela
    Versluis, Antheunis
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (06): : 1250e1 - 1250e8
  • [33] Effects of polishing techniques on the surface roughness of acrylic denture base resins
    Kuhar, M
    Funduk, N
    JOURNAL OF PROSTHETIC DENTISTRY, 2005, 93 (01): : 76 - 85
  • [35] A comparative study of cytopathogenic effects of four denture base acrylic resins
    Cimpan, MR
    Gjertsen, BT
    Skaug, N
    Gjerdet, NR
    Hansen, B
    Matre, R
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 816 - 816
  • [36] Effect of staining and denture cleaning on color stability of differently polymerized denture base acrylic resins
    Ayaz, E. A.
    Ustun, S.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (03) : 304 - 309
  • [37] A COMPARISON OF DENTURE BASE ACRYLIC RESINS POLYMERIZED BY MICROWAVE IRRADIATION AND BY CONVENTIONAL WATER BATH CURING SYSTEMS
    ALDOORI, D
    HUGGETT, R
    BATES, JF
    BROOKS, SC
    DENTAL MATERIALS, 1988, 4 (01) : 25 - 32
  • [38] Effect of different forms of steel strengtheners on the fracture resistance of the acrylic resin complete denture base
    Sanad, M.E.E.
    Mohsen, R.M.
    Elkhaly, M.R.
    Modelling, Measurement and Control C, 1993, 39 (01): : 1 - 28
  • [39] Fracture toughness of denture base resins using a rapid heating
    Kondo, S
    Ohkawa, S
    Uo, M
    Sugawara, T
    Watari, F
    JOURNAL OF DENTAL RESEARCH, 2000, 79 : 370 - 370
  • [40] DENTURE BASE RESINS
    WINKLER, S