Is There Any Relationship Between Serum Endocan Levels and Carotid Intima-media Thickness in Patients with Fibromyalgia?

被引:1
|
作者
Bagcier, Fatih [1 ]
Tufanoglu, Fatih Hakan [2 ]
Kadicesme, Ozgur [3 ]
机构
[1] Kars Harakani State Hosp, Clin Phys Theraphy & Rehabil, Kars, Turkey
[2] Kars Harakani State Hosp, Clin Radiol, Kars, Turkey
[3] Kars Harakani State Hosp, Clin Biochem, Kars, Turkey
关键词
Carotid intima-media thickness; fibromyalgia; endocan; correlation; SUBCLINICAL ATHEROSCLEROSIS; INFLAMMATION; DYSFUNCTION; IL-6;
D O I
10.4274/tod.galenos.2019.16023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although the pathophysiology of Fibromyalgia syndrome (FMS) has not yet been completely elucidated, it has been suggested that inflammation and endothelial dysfunction occur in patients with FMS. In recent years, endocan has been reported as an important biomarker for inflammation and endothelial dysfunction. It is important to assess carotid intima-media thickness (CIMT) in the evaluation of early atherosclerotic vascular diseases. In this study, we investigated this mechanism by measuring serum endocan levels and CIMT in patients with FMS and evaluated whether there is a correlation between them. Materials and Methods: Serum samples collected from 40 female patients diagnosed with FMS (the patient group) for the first time and 40 healthy female participants' (the control group) endocan levels and CIMT ultrasonography were investigated, and the values of the two groups were compared. Results: Serum endocan levels and CIMT results were significantly higher in the patient group than in the control group (p<0.001). In addition, a very weak correlation was found between CIMT and endocan levels in patients with FMS. Conclusion: Increased subclinical inflammation, endothelial dysfunction, and early atherosclerosis play an important role in the pathophysiology of FMS. Increased endocan levels, CIMT, and the correlation between them will contribute to elucidating this mechanism.
引用
收藏
页码:49 / 52
页数:4
相关论文
共 50 条
  • [11] Relationship between plasma plant sterol levels and carotid intima-media thickness
    Cofan, M.
    Junyent, M.
    Gilabert, R.
    Escurriol, V.
    Zambon, D.
    Ros, E.
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2007, 8 (01) : 113 - 113
  • [12] The relationship between serum uric acid level and carotid intima-media thickness in hemodialysis patients
    Kara, Ali Veysel
    Inan, Hamza
    Durmaz, Onder
    Ozdemir, Ridvan
    [J]. HEMODIALYSIS INTERNATIONAL, 2024,
  • [13] RELATIONSHIP BETWEEN SERUM PHOSPHATE LEVELS AND CAROTID INTIMA MEDIA THICKNESS IN HEMODIALYSIS PATIENTS
    Yonata, Ade
    Effendi, Ian
    Ali, Zulkhair
    Indrajaya, Taufik
    Suhaimi, Novadian
    Suprapti
    Bahar, Erial
    [J]. NEPHROLOGY, 2019, 24 : 38 - 38
  • [14] Relationship between thrombin generation and carotid intima-media thickness
    Bernhard, H.
    Wipfler, P.
    Leschnik, B.
    Novak, M.
    Kraus, J.
    Pilz, G.
    Ladurner, G.
    Muntean, W.
    [J]. HAMOSTASEOLOGIE, 2010, 30 (4A): : S168 - S171
  • [15] The relationship between carotid intima-media thickness and global atherosclerosis
    Lundberg, C.
    Hansen, T.
    Ahlstrom, H.
    Lind, L.
    Wikstrom, J.
    Johansson, L.
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2014, 34 (06) : 457 - 462
  • [16] Relationship between Carotid Intima-Media Thickness and Proteinuria in Patients with Metabolic Syndrome
    Ayar, Yavuz
    Atalay, Hande
    Boyuk, Banu
    Sayilar, Emel Isiktas
    Sahin, Ahmet Bilgehan
    Gomleksiz, Muhammet Ridvan
    Karaduman, Riza
    Celebi, Aslan
    [J]. JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2014, 4 (03): : 115 - 120
  • [17] Exploring the Relationship Between Serum Phosphate Levels and Carotid Intima-Media Thickness in Chronic Kidney Disease Patients: A Correlational Analysis
    Prabhakar, K.
    Anitha, A.
    Sanjana, M.
    Prasad, Roshan
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (05)
  • [18] LOW SERUM BILIRUBIN LEVELS AND INCREASED CAROTID INTIMA-MEDIA THICKNESS
    Kim, H. C.
    [J]. ATHEROSCLEROSIS SUPPLEMENTS, 2009, 10 (02)
  • [19] Increased serum chemerin levels associated with carotid intima-media thickness
    Demir, Caner Feyzi
    Atas, Iklimya Nimet
    Balgetir, Ferhat
    Artas, Hakan
    Gonen, Murat
    Aydin, Suleyman
    [J]. ARQUIVOS DE NEURO-PSIQUIATRIA, 2021, 79 (03) : 189 - 194
  • [20] Serum homocysteine levels in highway toll collectors and the relationship with intima-media thickness of the carotid artery
    Memisogullari, Ramazan
    Erdogmus, Besir
    Alp, Hamit Hakan
    Bilgin, Cahit
    Arbak, Peri Meram
    Yavuz, Oezlem
    [J]. TURKISH JOURNAL OF MEDICAL SCIENCES, 2008, 38 (02) : 133 - 137