Evaluation of an electronic cowside test to detect subclinical ketosis in dairy cows

被引:223
|
作者
Iwersen, M. [1 ]
Falkenberg, U. [1 ]
Voigtsberger, R. [1 ]
Forderung, D. [1 ]
Heuwieser, W. [1 ]
机构
[1] Free Univ Berlin, Fac Vet Med, Clin Anim Reprod, D-14163 Berlin, Germany
关键词
subclinical ketosis; beta-hydroxybutyrate; diagnostic test; whole blood; MILK;
D O I
10.3168/jds.2008-1795
中图分类号
S8 [畜牧、 动物医学、狩猎、蚕、蜂];
学科分类号
0905 ;
摘要
The objective of this study was to determine the diagnostic performance of an electronic beta-hydroxybutyrate (BHBA) hand-held meter (Precision Xtra) for use in dairy cattle. Specific objectives were to compare the electronic BHBA meter with serum BHBA concentrations determined photometrically and 2 commonly used chemical cowside tests (Ketostix, Ketolac) and to evaluate accuracy in a field study employing 35 investigators. Of the 196 blood samples collected in experiment 1, 17 (8.7%) contained >= 1,200 mu mol of BHBA/L of blood and 10 (5.1%) contained >= 1,400 mu mol of BHBA/L of blood. Pearson correlation coefficients were highly significant for all tests. The highest correlation coefficient (0.95) was found between measurements of whole blood BHBA determined with the Precision Xtra test and the serum BHBA concentrations determined photometrically. Correlation coefficients between serum BHBA and BHBA in urine using Precision Xtra and Ketostix, and milk using Ketolac were lower. The Precision Xtra test was both 100% sensitive and specific at >= 1,400 mu mol of BHBA/L of whole blood. Using milk and urine, positive and negative predictive values were considerably lower for both chemical tests as well as for the electronic meter. In the second study undertaken with 35 bovine veterinary practices, 926 blood samples were collected. In this study, the Precision Xtra test had sensitivities of 88 and 96% at 1,200 and 1,400 mu mol of BHBA/L of whole blood, respectively. Specificities were 96 and 97%, respectively. Level of agreement was lower in the second study employing multiple investigators. Considerable differences in variance occurred among investigators. We conclude that the electronic hand-held BHBA measuring system using whole blood is a useful and practical tool to diagnose subclinical ketosis. Sensitivity and specificity are excellent for a cowside test and higher than 2 commonly used chemical dipsticks (Ketostix and Ketolac).
引用
收藏
页码:2618 / 2624
页数:7
相关论文
共 50 条
  • [1] Evaluation of five cowside tests for use with milk to detect subclinical ketosis in dairy cows
    Geishauser, T
    Leslie, K
    Kelton, D
    Duffield, T
    [J]. JOURNAL OF DAIRY SCIENCE, 1998, 81 (02) : 438 - 443
  • [2] EVALUATION OF 2 COWSIDE TESTS FOR THE DETECTION OF SUBCLINICAL KETOSIS IN DAIRY-COWS
    NIELEN, M
    AARTS, MGA
    JONKERS, AGM
    WENSING, T
    SCHUKKEN, YH
    [J]. CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 1994, 35 (04): : 229 - 232
  • [3] Comparison of 2 electronic cowside tests to detect subclinical ketosis in dairy cows and the influence of the temperature and type of blood sample on the test results
    Iwersen, M.
    Klein-Joebstl, D.
    Pichler, M.
    Roland, L.
    Fidlschuster, B.
    Schwendenwein, I.
    Drillich, M.
    [J]. JOURNAL OF DAIRY SCIENCE, 2013, 96 (12) : 7719 - 7730
  • [4] Evaluation and use of an automated human β-hydroxybuturate (BHBA) test for cowside detection of subclinical ketosis in dairy cattle
    Heuwieser, W.
    Falkenberg, U.
    Iwersen, M.
    Voigtsberger, R.
    Padberg, W.
    [J]. PROCEEDINGS OF THE FORTIETH ANNUAL CONFERENCE AMERICAN ASSOCIATION OF BOVINE PRACTITIONERS, 2007, : 253 - 254
  • [5] Evaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows
    Carrier, J
    Stewart, S
    Godden, S
    Fetrow, J
    Rapnicki, P
    [J]. JOURNAL OF DAIRY SCIENCE, 2004, 87 (11) : 3725 - 3735
  • [6] SUBCLINICAL KETOSIS IN DAIRY-COWS
    ANDERSSON, L
    [J]. VETERINARY CLINICS OF NORTH AMERICA-FOOD ANIMAL PRACTICE, 1988, 4 (02) : 233 - 251
  • [7] Detection of Subclinical Ketosis in Dairy Cows
    Zhang, Zhigang
    Liu, Guowen
    Wang, Hongbin
    Li, Xiaobing
    Wang, Zhe
    [J]. PAKISTAN VETERINARY JOURNAL, 2012, 32 (02) : 156 - 160
  • [8] Evaluation of a point-of-care electrochemical meter to detect subclinical ketosis and hypoglycaemia in lactating dairy cows
    Zakian, A.
    Tehrani-Sharif, M.
    Mokhber-Dezfouli, M. R.
    Nouri, M.
    Constable, P. D.
    [J]. AUSTRALIAN VETERINARY JOURNAL, 2017, 95 (04) : 123 - 128
  • [9] Renal function of dairy cows with subclinical ketosis
    Wang, Zhe
    [J]. VETERINARY RECORD, 2011, 169 (10) : 262 - 262
  • [10] Renal function of dairy cows with subclinical ketosis
    Li, X. B.
    Zhang, Z. G.
    Liu, G. W.
    Wang, H. B.
    Li, Y. F.
    Gao, L.
    Wang, Z.
    [J]. VETERINARY RECORD, 2011, 168 (24) : 643