Study on flow field characteristics in a reverse rotation cyclone with PIV

被引:24
|
作者
He, Mengya [1 ]
Zhang, Yanhong [1 ]
Ma, Liang [1 ]
Wang, Huanglin [1 ]
Fu, Pengbo [1 ]
Zhao, Zhihuang [1 ]
机构
[1] East China Univ Sci & Technol, State Environm Protect Key Lab Environm Risk Ass, 130 Meilong Rd, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Reverse-rotation cyclone; Particle image velocimetry testing (PIV); Velocity distribution; Computational fluid dynamics simulation (CFD); SEPARATION EFFICIENCY; RECYCLED HYDROGEN; GAS; HYDROCYCLONE; CFD; SIMULATION;
D O I
10.1016/j.cep.2018.02.026
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study adopted particle image velocimetry (PIV) to understand flow-field movements in the conventional cyclone and reverse-rotation cyclone (RC). Tracer particles were prepared by preparing a 5-wt% sugar solution at normal temperature and pressure for velocity measurement, cloud and distribution velocity maps were generated at various flow rates using three cross-sections. Compared with conventional cyclone, the PIV testing results indicate that the tangential and radial velocities of RC increased at higher flow rates and decreased at lower heights, suggesting adequate radially symmetric distributions despite variations in heights and flow rates. The radial velocity exhibited adequate diagonally symmetric distribution, implying that the indicating excellent symmetry and regularity in the velocity distribution of the flow-field images of the separator, a sign of stable flow fields in the separator. Finally, the comparison showed a similar distribution and variation patterns, which was collected through PIV testing and computational fluid dynamics (CFD) simulation.
引用
收藏
页码:100 / 107
页数:8
相关论文
共 50 条
  • [31] Study on Flow Field in New Bioreactor by PIV in Lower Onflow State
    Xu, Shu
    2012 INTERNATIONAL WORKSHOP ON INFORMATION AND ELECTRONICS ENGINEERING, 2012, 29 : 3939 - 3943
  • [32] Experimental Study on Flow Structure Characteristics of Gap Flow Boundary Layer Based on PIV
    Sun, Lei
    Sun, Xihuan
    Li, Yongye
    Wang, Cheng
    WATER, 2023, 15 (22)
  • [33] Study of the flow characteristics of the ultrasonic heat meter based on the method of PIV
    Liu, Yonghui
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2015, 36 : 57 - 61
  • [34] Experimental study of flow field around pile groups using PIV
    Yang, Yilin
    Qi, Meilan
    Li, Jinzhao
    Ma, Xiaodong
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2021, 120
  • [35] Performance analysis of axial and reverse flow cyclone separators
    Sakin, Ali
    Karagoz, Irfan
    Avci, Atakan
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2019, 144
  • [36] Flow field characteristics of single round hole pulsed jet based on PIV technology
    Shen X.
    Mao J.
    Liu F.
    Fan J.
    Han X.
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2020, 35 (09): : 1845 - 1855
  • [37] CALCULATION OF FIELD OF FLOW IN A CYCLONE SEPARATOR
    MEISSNER, P
    LOFFLER, F
    CHEMIE INGENIEUR TECHNIK, 1978, 50 (06) : 471 - 471
  • [38] Study on Flow Field Intensification of Dynamic Pre-cyclone Separators
    Zou Jiupeng
    Liu Fengxia
    Dai Yuqiang
    Wu Jintao
    Liu Peiqi
    Zhu Che
    Zhang Liming
    Hu Dapeng
    ADVANCES IN CHEMICAL ENGINEERING II, PTS 1-4, 2012, 550-553 : 3210 - 3213
  • [39] Experimental study of flow field in cyclone separator with direct outlet tube
    Lin, Wei
    Zhang, Yuhong
    Wang, Naining
    Huadong Gongye Daxue Xuebao/Journal of East China University of Technology, 19 (03): : 26 - 30
  • [40] Study and optimization of flow field in a novel cyclone separator with inner cylinder
    Duan, Jihai
    Gao, Shun
    Lu, Yuanchun
    Wang, Weiwen
    Zhang, Pan
    Li, Chaojie
    ADVANCED POWDER TECHNOLOGY, 2020, 31 (10) : 4166 - 4179