Sensitive method for endotoxin determination in nanomedicinal product samples

被引:15
|
作者
Giannakou, Christina [1 ,2 ]
Aimonen, Kukka [3 ]
van Bloois, Louis [4 ]
Catalan, Julia [3 ,5 ]
Geertsma, Robert E. [1 ]
Gremmer, Eric R. [1 ]
de Jong, Wim H. [1 ]
Keizers, Peter H. J. [1 ]
Schwillens, Paul L. W. J. [1 ]
Vandebriel, Rob J. [1 ]
Park, Margriet V. D. Z. [1 ]
机构
[1] Natl Inst Publ Hlth & Environm RIVM, Ctr Hlth Protect, Bilthoven, Netherlands
[2] Maastricht Univ, Dept Toxicogen, Maastricht, Netherlands
[3] Finnish Inst Occupat Hlth, Helsinki, Finland
[4] Univ Utrecht, Utrecht, Netherlands
[5] Univ Zaragoza, Zaragoza, Spain
关键词
fatty acids; interference; LAL assay; lipopolysaccharide; nanomaterials; nanomedicine; GAS-CHROMATOGRAPHY; BACTERIAL LIPOPOLYSACCHARIDES; MASS-SPECTROMETRY; NANOPARTICLES; NANOMATERIALS; CONTAMINATION; DOXORUBICIN; TOXICITY; DELIVERY; SYSTEMS;
D O I
10.2217/nnm-2018-0339
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Aim: Nanomaterials and nanomedicinal products tend to interfere with various commonly used assays, including regulatory required endotoxin detection methods for medicines. We developed a method to quantify endotoxin levels that is compatible with nanomaterials and nanomedicinal products. Materials & methods: The method is based on measuring endotoxin indirectly via 3-hydroxylated fatty acids of lipid-A, using Ultra High Performance Liquid Chromatography coupled with mass spectrometry. The outcome was related to results of the commonly used Limulus Amebocyte Lysate method. Results: The ultra high performance liquid chromatography coupled with mass spectrometry method has clear advantages compared with other endotoxin determination assays; particularly the absence of nanospecific interference. Conclusion: The method is sensitive, straightforward and accurate in determining and quantifying endotoxin in nanomedicinal product samples.
引用
收藏
页码:1231 / 1246
页数:16
相关论文
共 50 条
  • [21] A simple and sensitive method for determination of carbon disulphide in environmental and biological samples
    Tamrakar, Urmila
    Gupta, V. K.
    Mathew, Sunitha B.
    Pillai, Ajai K.
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2008, 15 (03) : 306 - 309
  • [22] Sensitive Spectrophotometric Method for Determination of Trace Aluminium in Water Samples by Morin
    Yuan Dong
    Fu Dayou
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 2173 - 2176
  • [23] A NEW AND SENSITIVE METHOD FOR THE SPECTROPHOTOMETRIC DETERMINATION OF ETHION IN ENVIRONMENTAL AND BIOLOGICAL SAMPLES
    DAS, JV
    GUPTA, VK
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (3-4): : 395 - 396
  • [25] A Simple and Sensitive Analytical Method for the Determination of Antimony in Environmental and Biological Samples
    Kishore K. Tiwari
    Girdhar L. Mundhara
    Manish K. Rai
    Vinay K. Gupta
    Analytical Sciences, 2006, 22 : 259 - 262
  • [26] A rapid and sensitive method for the determination of cobalt in pharmaceutical and ink dryer samples
    Pawar, RB
    Padgaonkar, SB
    Sawant, AD
    JOURNAL OF SCIENTIFIC & INDUSTRIAL RESEARCH, 2001, 60 (04): : 328 - 330
  • [27] A simple and sensitive analytical method for the determination of antimony in environmental and biological samples
    Tiwari, KK
    Mundhara, GL
    Rai, MK
    Gupta, VK
    ANALYTICAL SCIENCES, 2006, 22 (02) : 259 - 262
  • [28] A new sensitive method for the spectrophotometric determination of fenthion in environmental and biological samples
    Das, JV
    Gupta, VK
    CHEMIA ANALITYCZNA, 1996, 41 (05): : 801 - 807
  • [29] A rapid and sensitive analytical method for the determination of 14 pyrethroids in water samples
    Feo, M. L.
    Eljarrat, E.
    Barcelo, D.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (15) : 2248 - 2253
  • [30] SENSITIVE SPECTROPHOTOMETRIC METHOD FOR MEASUREMENT OF PLASMA ENDOTOXIN
    HOLLANDER, VP
    HARDING, WC
    BIOCHEMICAL MEDICINE, 1976, 15 (01): : 28 - 33