Inappropriate implantable defibrillator discharges from lead failure

被引:0
|
作者
Hiew, Chin V. [1 ]
Leitch, James W. [1 ]
机构
[1] John Hunter Hosp, Cardiovasc Dept, Newcastle, NSW, Australia
关键词
D O I
10.5694/j.1326-5377.2009.tb02290.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:97 / 98
页数:2
相关论文
共 50 条
  • [11] Inappropriate implantable defibrillator discharge caused by a retained pacemaker lead fragment
    Lickfett, L
    Wolpert, C
    Jung, W
    Spehl, S
    Pizzulli, L
    Esmailzadeh, B
    Lüderitz, B
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 1999, 3 (02) : 163 - 167
  • [12] Inappropriate Implantable Defibrillator Discharge Caused by a Retained Pacemaker Lead Fragment
    Lars Lickfett
    Christian Wolpert
    Werner Jung
    Susanne Spehl
    Luciano Pizzulli
    Bahman Esmailzadeh
    Berndt L¨deritz
    Journal of Interventional Cardiac Electrophysiology, 1999, 3 : 163 - 167
  • [13] INAPPROPRIATE DISCHARGES BY THE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR DURING POSTOPERATIVE TESTING - IMPLICATIONS FOR INTRAOPERATIVE ASSESSMENT
    SULKE, N
    HOLT, P
    BOSTOCK, J
    YATES, A
    SOWTON, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (09): : 1123 - 1126
  • [14] Inappropriate discharges of an implantable cardioverter defibrillator secondary to automatic adjustable gain of atrial tachycardia
    Schechter, SO
    Greenberg, SM
    Hoch, DH
    Cesa, M
    Levine, JH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (06): : 1721 - 1722
  • [15] FAILURE OF ONE CONDUCTOR IN A NONTHORACOTOMY IMPLANTABLE DEFIBRILLATOR LEAD CAUSING INAPPROPRIATE SENSING AND POTENTIALLY INEFFECTIVE SHOCK DELIVERY
    EPSTEIN, AE
    SHEPARD, RB
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (04): : 796 - 800
  • [16] Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure
    Spencker, Sebastian
    Coban, Nalan
    Koch, Lydia
    Schirdewan, Alexander
    Mueller, Dirk
    EUROPACE, 2009, 11 (04): : 483 - 488
  • [17] Management of the Patient With Implantable Cardioverter-Defibrillator Lead Failure
    Kalahasty, Gautham
    Ellenbogen, Kenneth A.
    CIRCULATION, 2011, 123 (12) : 1352 - 1354
  • [18] Increasing risk of sprint fidelis implantable defibrillator lead failure
    Hauser, R. G.
    Hayes, D. L.
    Kallinen, L. M.
    Rott, M.
    EUROPEAN HEART JOURNAL, 2009, 30 : 278 - 278
  • [19] Increased failure rate of a polyurethane implantable cardioverter defibrillator lead
    Maisel, WH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (06): : 877 - 878
  • [20] Lead failure in an entirely subcutaneous implantable cardioverter-defibrillator
    Kolb, Christof
    Weigand, Severin
    Schaarschmidt, Claudia
    Lennerz, Carsten
    EUROPACE, 2020, 22 (02): : 183 - 183