Inappropriate implantable defibrillator discharges from lead failure

被引:0
|
作者
Hiew, Chin V. [1 ]
Leitch, James W. [1 ]
机构
[1] John Hunter Hosp, Cardiovasc Dept, Newcastle, NSW, Australia
关键词
D O I
10.5694/j.1326-5377.2009.tb02290.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:97 / 98
页数:2
相关论文
共 50 条
  • [1] PREDICTORS OF INAPPROPRIATE IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR DISCHARGES
    Catanzaro, John N.
    Makaryus, Amgad
    Makaryus, John
    Sison, Cristina
    Vavasis, Christos
    Donaldson, David
    Altman, Erik
    Beldner, Stuart
    Jadonath, Ram
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E172 - E172
  • [2] Inappropriate discharges of intravenous implantable cardioverter defibrillators owing to lead failure
    Washizuka, T
    Chinushi, M
    Kazama, R
    Hirono, T
    Watanabe, H
    Komura, S
    Sugiura, H
    Tanabe, Y
    Furushima, H
    Fujita, S
    Okura, Y
    Aizawa, Y
    INTERNATIONAL HEART JOURNAL, 2005, 46 (05) : 909 - 913
  • [3] The Impact of Inappropriate Shocks from Implantable Cardiac Defibrillator Lead Failure on Cardiovascular Morbidity and Mortality
    Oza, Nishaki Mehta
    Taylor, Montoya
    Kalbfleisch, Steven
    CIRCULATION, 2013, 128 (22)
  • [4] Inappropriate defibrillator discharges caused by an unusual interaction between an implantable cardioverter defibrillator and a pacemaker
    Liao, PC
    Lai, LP
    Lin, JL
    Huang, SKS
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (11) : 1178 - 1179
  • [5] Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias
    Occhetta, Eraldo
    Bortnik, Miriam
    Magnani, Andrea
    Francalacci, Gabriella
    Marino, Paolo
    EUROPACE, 2006, 8 (10): : 863 - 869
  • [6] INAPPROPRIATE IMPLANTABLE CARDIOVERTER DEFIBRILLATOR SHOCKS SECONDARY TO SENSING LEAD FAILURE - UTILITY OF STORED ELECTROGRAMS
    ALMEIDA, HF
    BUCKINGHAM, TA
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (03): : 407 - 411
  • [7] Inappropriate discharges from an intravenous implantable cardioverter defibrillator due to T-wave oversensing
    Washizuka, T
    Chinushi, M
    Kasai, H
    Watanabe, H
    Tagawa, M
    Hosaka, Y
    Abe, A
    Aizawa, Y
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 2001, 65 (07): : 685 - 687
  • [8] Implantable Cardiac Defibrillator Lead Failure and Management
    Swerdlow, Charles D.
    Kalahasty, Gautham
    Ellenbogen, Kenneth A.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (11) : 1358 - 1368
  • [9] Inappropriate sensing events revealing electrocautery-induced implantable cardioverter-defibrillator lead failure
    Can, Ilknur
    Aribas, Alpay
    Dereli, Yuksel
    Tholakanalli, Venkatakrishna
    ANATOLIAN JOURNAL OF CARDIOLOGY, 2015, 15 (10): : E27 - E27
  • [10] Inappropriate Implantable Defibrillator Shocks
    Raitt, Merritt H.