Influences of Pentagonal Ribs on the Performance of Rectangular Solar Air Collector

被引:8
|
作者
Debnath, Suman [1 ]
Das, Biplab [1 ]
Randive, Pitambar [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Silchar 788010, Assam, India
关键词
Thermal performance; Nusselt number; friction factor; entropy generation; CFD; HEAT-TRANSFER; FLUID-FLOW; ROUGHNESS; SURFACE;
D O I
10.1016/j.egypro.2019.01.300
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In the present study, 2-D fluid flow and heat transfer characteristic in a roughened rectangular duct with pentagonal ribs are being numerically investigated. The influences of the Reynolds number, non-dimensional relative height, non-dimensional relative pitch on the thermal performance factor and hydraulic performance factor are discussed. The numerical analysis is carried out using commercial available CFD code ANSYS FLUENT 14.0 finite-volume version to simulate turbulent fluid flow through pentagon roughened solar air collector. The Renormalization-group k-e model is used, and for that forecasted results are nearly very close to the experimental results. The range of parameters that have been used are Reynolds number = 12633-62842 (5 steps), non-dimensional roughness height of e/D = 0.045, 0.066, and 0.084, and non-dimensional roughness pitch of P/e = 6.43, 7.27, and 8. As compared to the smooth duct pentagonal ribs shows better enhancement in terms of thermal performance. The best configuration that has been found is e/D = 0.045 and P/e = 8 for Re = 38414 in which enhancement of the Nusselt number and friction factor by 70% and 67.2% respectively have been done. (C) 2019 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1168 / 1173
页数:6
相关论文
共 50 条
  • [1] Influence of Rectangular Ribs on Exergetic Performance in a Triangular Duct Solar Air Heater
    Nidhul, Kottayat
    Kumar, Sachin
    Yadav, Ajay Kumar
    Anish, S.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2020, 12 (05)
  • [2] Numerical analysis of pentagonal ribbed absorber plate of solar air collector in an indirect solar dryer for enhanced performance
    Adavi, Sai Sreeharsha
    Chandramohan, V. P.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 3363 - 3380
  • [3] CFD analysis of solar air collector equipped with flexible ribs
    Bouzaher, Mohamed Taher
    Baissi, Mohamed Tahar
    Abdelbasset, Chebana
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2016, 38 (08) : 2289 - 2297
  • [4] CFD analysis of solar air collector equipped with flexible ribs
    Mohamed Taher Bouzaher
    Mohamed Tahar Baissi
    Chebana abdelbasset
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2016, 38 : 2289 - 2297
  • [5] Hydrothermal performance of humid air flow in a rectangular solar air heater equipped with V-shaped ribs
    Kadijani, Omid Nouri
    Moghadam, Hamid Kazemi
    Ajarostaghi, Seyed Soheil Mousavi
    Asadi, Asgar
    Pour, Mohsen Saffari
    ENERGY SCIENCE & ENGINEERING, 2022, 10 (07) : 2276 - 2289
  • [6] Thermal–Hydraulic Performance of a V-Groove Solar Air Collector with Transverse Wedge-Shaped Ribs
    Ammar A. Farhan
    Hamdi E. Ahmed
    Munther A. Mussa
    Arabian Journal for Science and Engineering, 2022, 47 : 8915 - 8930
  • [7] Experimental Investigation of Heat Transfer Enhancement in Rectangular Duct with Pentagonal Ribs
    Sharma, Naveen
    Tariq, Andallib
    Mishra, Manish
    HEAT TRANSFER ENGINEERING, 2019, 40 (1-2) : 147 - 165
  • [8] Computational and experimental performance assessment of rectangular sectioned solar air heater duct provided with new curved ribs
    Deshpande, Harshad
    Raibhole, Vaijanath
    HEAT TRANSFER, 2024, 53 (04) : 1924 - 1948
  • [9] Performance of a double pass solar air collector
    Ramani, B. M.
    Gupta, Akhilesh
    Kumar, Ravi
    SOLAR ENERGY, 2010, 84 (11) : 1929 - 1937
  • [10] Performance study of a novel solar air collector
    Peng, Donggen
    Zhang, Xiaosong
    Dong, Hua
    Lv, Kun
    APPLIED THERMAL ENGINEERING, 2010, 30 (16) : 2594 - 2601