Evaluation of Human Corneal Lenticule Quality After SMILE With Different Cap Thicknesses Using Scanning Electron Microscopy

被引:14
|
作者
Weng, Shengbei [1 ]
Liu, Manli [1 ]
Yang, Xiaonan [1 ]
Liu, Fang [1 ]
Zhou, Yugui [1 ]
Lin, Haiqin [1 ]
Liu, Quan [1 ]
机构
[1] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou 510060, Guangdong, Peoples R China
关键词
small-incision lenticule extraction; scanning electron microscope; cap thicknesses; surface regularity; lenticule; EXTRACTION SMILE; FLAP DIMENSIONS; SURFACE QUALITY; EXCIMER-LASER; KERATOMILEUSIS; OUTCOMES; SURGERY; MYOPIA; MODEL; LASIK;
D O I
10.1097/ICO.0000000000001404
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the surface characteristics of lenticules created by small-incision lenticule extraction (SMILE) with different cap thicknesses. Methods: This prospective study included 20 consecutive patients who underwent bilateral SMILE. Surface regularity of the extracted corneal lenticule was analyzed using scanning electron microscopy (SEM) combined with 2 methods: qualitative and quantitative regularity. Qualitative regularity of SEM images was graded by masked observers using an established scoring system. Quantitative regularity of SEM images was assessed by counting the total number and areas of tissue bridges using Image-Pro Plus software. Four different cap thickness of 120, 130, 140, and 150 mm were compared. Refractive outcomes of patients were measured at baseline and 1 month after surgery. Results: As 10 specimens were not analyzable, only 30 eyes were included. Postoperatively, all eyes had postoperative uncorrected distance visual acuity of 20/20 or better; 43% had an unchanged corrected distance visual acuity; 43% gained 1 line; 10% lost 1 line. Ultrastructurally, surface irregularity was primarily caused by tissue bridges. The average surface regularity score obtained was 10.87 6 2.40 for 120 mu m, 10.78 +/- 2.60 for 130 mu m, 8.76 +/- 2.16 for 140 mu m, and 8.70 +/- 2.66 for 150 mu m (P, 0.001). The total number and areas of tissue bridges of 120 to 130 mu m were significantly less than 140 to 150 mu m (P < 0.05). Surface regularity decreased as cap thickness increased (P < 0.05). Conclusions: There is smoother appearance of the lenticular surface as seen through SEM when a thin cap is created compared with a thick cap qualitatively and quantitatively.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [1] Surface Quality of Human Corneal Lenticules After SMILE Assessed Using Environmental Scanning Electron Microscopy
    Ziebarth, Noel M.
    Lorenzo, Michael A.
    Chow, Jessica
    Cabot, Florence
    Spooner, Gregory J. R.
    Dishler, Jon
    Hjortdal, Jesper O.
    Yoo, Sonia H.
    JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (06) : 388 - 393
  • [2] Lenticule Quality After Continuous Curvilinear Lenticulerrhexis in SMILE Evaluated With Scanning Electron Microscopy
    Zhao, Yu
    Li, Meiyan
    Sun, Ling
    Zhao, Jing
    Chen, Yingjun
    Zhou, Xingtao
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (11) : 732 - 735
  • [3] A comparison of the effects of different cap thicknesses on corneal nerve destruction after small incision lenticule extraction
    Weiming Yang
    Meiyan Li
    Dan Fu
    Ruoyan Wei
    Chuanbo Cui
    Xingtao Zhou
    International Ophthalmology, 2020, 40 : 1905 - 1911
  • [4] A comparison of the effects of different cap thicknesses on corneal nerve destruction after small incision lenticule extraction
    Yang, Weiming
    Li, Meiyan
    Fu, Dan
    Wei, Ruoyan
    Cui, Chuanbo
    Zhou, Xingtao
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (08) : 1905 - 1911
  • [5] Comparison of Postoperative Safety, Efficacy, and Visual Quality after SMILE for Myopic Patients with Different Corneal Thicknesses
    Mao, Xiuyu
    Ji, Shunmei
    Chen, Han
    Dai, Jinhui
    CURRENT EYE RESEARCH, 2023, 48 (01) : 18 - 24
  • [6] Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses
    Xiaotong Lv
    Fengju Zhang
    Yanzheng Song
    Changbin Zhai
    Ning Guo
    Lingbo Lai
    Yushan Xu
    BMC Ophthalmology, 23
  • [7] Using scanning electron microscopy for quality evaluation of apples after cold storage
    Ribeiro, CJO
    Bandeira-Tavares, P
    Rosa, EAS
    Meireles, O
    Silva, A
    Proceedings of the 5th International Postharvest Symposium, Vols 1-3, 2005, (682): : 715 - 721
  • [8] Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses
    Lv, Xiaotong
    Zhang, Fengju
    Song, Yanzheng
    Zhai, Changbin
    Guo, Ning
    Lai, Lingbo
    Xu, Yushan
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [9] Corneal subbasal nerve plexus reinnervation and stromal cell morphology with different cap thicknesses in small incision lenticule extraction
    Song, Yanzheng
    Deng, Shijing
    Lyv, Xiaotong
    Xu, Yushan
    Zhang, Fengju
    Guo, Ning
    EYE AND VISION, 2024, 11 (01)
  • [10] Comparison of different corneal residual bed thickness after small incision lenticule extraction (SMILE)
    Ouyang, Bo-wen
    Ding, Hui
    Fan, Hongming
    Wang, Han
    Yang, Zhenduo
    Zhong, Tan
    Zhong, Xingwu
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (02) : 384 - 393