Improving the therapeutic ratio of prostate brachytherapy: Dose escalation in I-125 prostate implants

被引:0
|
作者
Kao, J. [1 ]
Cesaretti, J. A. [1 ]
Dumane, V. [1 ]
Stone, N. N. [1 ]
Stock, R. G. [1 ]
机构
[1] Mt Sinai Sch Med, New York, NY USA
关键词
D O I
10.1016/j.ijrobp.2006.07.609
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2203
引用
收藏
页码:S323 / S323
页数:1
相关论文
共 50 条
  • [1] I-125 IMPLANTS FOR CARCINOMA OF THE PROSTATE
    PESCHEL, RE
    FOGEL, TD
    KACINSKI, BM
    KELLY, K
    MATE, TP
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1985, 11 (10): : 1777 - 1781
  • [2] A dose-response study for I-125 prostate implants
    Stock, RG
    Stone, NN
    Tabert, A
    Iannuzzi, C
    DeWyngaert, JK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (01): : 101 - 108
  • [3] Dose perturbation effects in prostate seed implant brachytherapy with I-125
    Mobit, P
    Badragan, I
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (14): : 3171 - 3178
  • [4] A biological approach to optimisation of permanent I-125 prostate implants for focal brachytherapy
    Haworth, A.
    Mears, C.
    Betts, J.
    Reynolds, H.
    Williams, S.
    Ebert, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S63 - S64
  • [5] Prostate brachytherapy with permanent I-125 seed implants -: first experiences at the KSSG
    Töpfer, M
    Prikler, L
    Seelentag, W
    Ries, G
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 121 - 121
  • [6] DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS
    Ivanauskas, Andrius
    Aleknavicius, Eduardas
    Burneckis, Arvydas
    Miller, Albert
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2011, : 98 - 101
  • [7] Statistical analysis of I-125 prostate brachytherapy
    Jang, S.
    Pyakuryal, A.
    Sathiaseelan, V.
    Luo, J.
    Kalapurakal, J.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2490 - 2490
  • [8] INTERSEED EFFECTS ON DOSE FOR I-125 BRACHYTHERAPY IMPLANTS
    MEIGOONI, AS
    MELI, JA
    NATH, R
    [J]. MEDICAL PHYSICS, 1992, 19 (02) : 385 - 390
  • [9] A simple method to evaluate the dose rate in the vicinity of patients undergoing prostate brachytherapy with I-125 permanent implants
    Rosenwald, JC
    Pentsch, B
    Solignac, S
    Timbert, M
    Clairand, I
    Bottolier-Depois, JF
    Trompier, F
    Itié, C
    Chauveinc, L
    Cosset, JM
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S238 - S238
  • [10] I-125 isodose patterns as predictors of inadequate prostate brachytherapy dose coverage
    Reed, D
    Wallner, K
    Cho, P
    Ford, E
    Merrick, G
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S123 - S124