DOSIMETRIC OPTIONS AND POSSIBILITIES OF PROSTATE LDR BRACHYTHERAPY WITH PERMANENT I-125 IMPLANTS

被引:0
|
作者
Ivanauskas, Andrius [1 ]
Aleknavicius, Eduardas [1 ]
Burneckis, Arvydas [1 ]
Miller, Albert [1 ]
机构
[1] Vilnius Univ, Inst Oncol, Vilnius, Lithuania
关键词
prostate LDR brachytherapy; permanent I-125 implants; adaptive brachytherapy; post implant dosimetry; loose seeds; stranded seeds; SEED IMPLANTATION; PATIENT SELECTION; CANCER; TIME; ULTRASOUND; SURVIVAL; LOOSE;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Article reviews dosimetric options of prostate LDR brachytherapy with permanent I-125 implants, including adaptive brachytherapy, dose escalation, real time planning, post implant dosimetry and implantation techniques. Also it pays attention to the prostate cancer diagnostics on the basis of modern radiological imaging.
引用
收藏
页码:98 / 101
页数:4
相关论文
共 50 条
  • [1] Post implant dosimetric evaluation of I-125 permanent prostate implants
    Kota, C
    Yudelev, M
    Chungbin, S
    Litrrup, P
    Wood, D
    Forman, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (02): : 346 - 346
  • [2] A biological approach to optimisation of permanent I-125 prostate implants for focal brachytherapy
    Haworth, A.
    Mears, C.
    Betts, J.
    Reynolds, H.
    Williams, S.
    Ebert, M.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S63 - S64
  • [3] Prostate brachytherapy with permanent I-125 seed implants -: first experiences at the KSSG
    Töpfer, M
    Prikler, L
    Seelentag, W
    Ries, G
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2004, 180 : 121 - 121
  • [4] PROSTATE LDR BRACHYTHERAPY WHITH PERMANENT I-125 SEEDS IMPLANT: RESULTS OF A RETROSPECTIVE ANALYSIS
    Chiumento, C.
    Montagna, A.
    Castaldo, G.
    Lapadula, L.
    Pedicini, P.
    Imbriani, E.
    Fusco, V
    [J]. ANNALS OF ONCOLOGY, 2009, 20
  • [5] Positional and directional accuracy in the placement of I-125 seeds in permanent prostate brachytherapy implants
    Golshan, Maryam Afsari
    Spadinger, Ingrid
    Mahdavi, Sara
    [J]. MEDICAL PHYSICS, 2017, 44 (08) : 4381 - 4381
  • [6] Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy
    Hueso-Gonzalez, F.
    Vijande, J.
    Ballester, F.
    Perez-Calatayud, J.
    Siebert, F.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3623 - 3623
  • [7] DOSIMETRIC COMPARISON BETWEEN LINKED AND STRAND SEEDS FOR I-125 PERMANENT SEED PROSTATE BRACHYTHERAPY
    Jakstas, Karolis
    Sniureviciute, Migle
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2010, (02): : 112 - +
  • [8] Dosimetric effect of tissue heterogeneity for I-125 prostate implants
    Oliveira, Susana Maria
    Teixeira, Nuno Jose
    Fernandes, Lisete
    Teles, Pedro
    Vaz, Pedro
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2014, 19 (06) : 392 - 398
  • [9] A single centre experience of dosimetric outcomes in LDR prostate brachytherapy with I-125 seeds prescribed to 160Gy
    O'Cathail, S. M.
    Day, K.
    Doggart, A.
    Rogers, P.
    O'Donnell, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S566 - S567
  • [10] Prostate brachytherapy (LDR) with 125I permanent implantation;: Experience at CROB
    Cocco, G.
    Iadanza, L.
    Zucca, S.
    Castaldo, G.
    Lapadula, L.
    Montagna, A.
    Mazziotta, M.
    Imbriani, E.
    Silvestre, G.
    Fusco, V.
    [J]. ANNALS OF ONCOLOGY, 2006, 17 : VII153 - VII153