Metabolic imaging of low-grade gliomas with three-dimensional magnetic resonance spectroscopy

被引:73
|
作者
Pirzkall, A
Nelson, SJ
McKnight, TR
Takahashi, MM
Li, XJ
Graves, EE
Verhey, LJ
Wara, WW
Larson, DA
Sneed, PK
机构
[1] Univ Calif San Francisco, Sch Med, Magnet Resonance Sci Ctr, Dept Radiat Oncol, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Sch Med, Magnet Resonance Sci Ctr, Dept Radiol, San Francisco, CA 94143 USA
关键词
magnetic resonance spectroscopy imaging; glioma; low-grade astrocytoma; central nervous system; conformal radiotherapy; intensity-modulated radiotherapy;
D O I
10.1016/S0360-3016(02)02869-9
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The role of radiotherapy (RT) seems established for patients with low-grade gliomas with poor prognostic factors. Three-dimensional (3D) magnetic resonance spectroscopy imaging (MRSI) has been reported to be of value in defining the extent of glioma infiltration. We performed a study examining the impact MRSI would have on the routine addition of 2-3-cm margins around MRI T2-weighted hyperintensity to generate the treatment planning clinical target volume (CTV) for low-grade gliomas. Methods and Materials: Twenty patients with supratentorial gliomas WHO Grade 11 (7 astrocytomas, 6 oligoastrocytomas, 7 oligodendrogliomas) underwent MRI and MRSI before surgery. The MRI was contoured manually; the regions of interest included T2 hyperintensity and, if present, regions of contrast enhancement on T1-weighted images. The 3D-MRSI peak parameters for choline and N-acetyl-aspartate, acquired voxel-by-voxel, were categorized using a choline/N-acetyl-aspartate index (CNI), a tool for quantitative assessment of tissue metabolite levels, with CNI 2 being the lowest value corresponding to tumor. CNI data were aligned to MRI and displayed as 3D contours. The relationship between the anatomic and metabolic information on tumor extent was assessed by comparing the CNI contours and other MRSI-derived metabolites to the MRI T2 volume. Results: The limitations in the size of the region "excited" meant that MRSI could be used to evaluate only a median 68% of the T2 volume (range 38-100%), leaving the volume T2c. The CNI 2 volume (median 29 cm(3), range 10-73) was contained totally within the T2c in 55% of patients. In the remaining patients, the volume of CNI 2 extending beyond the T2c was quite small (median 2.3 cm(3), range 1.4-5.2), but was not distributed uniformly about the T2c, extending up to 22 turn beyond it. Two patients demonstrated small regions of contrast enhancement corresponding to the regions of highest CNI. Other metabolites, such as creatine and lactate, seem useful for determining less and more radioresistant areas, respectively. Conclusion: Metabolically active tumor, as detected by MRSI, is restricted mainly to the T2 hyperintensity in low-grade gliomas, but can extend outside it in a limited and nonuniform fashion up to 2 cm. Therefore, a CTV including T2 and areas of CNI extension beyond the T2 hyperintensity would result in a reduction in the size and a change in the shape of the standard clinical target volumes generated by adding uniform margins of 2-3 cm to the T2 hyperintensity. (C) 2002 Elsevier Science Inc.
引用
收藏
页码:1254 / 1264
页数:11
相关论文
共 50 条
  • [31] Low-Grade Gliomas
    Jimmy Ruiz
    Glenn J. Lesser
    Current Treatment Options in Oncology, 2009, 10 : 231 - 242
  • [32] Tumor Volume Assessment in Low-Grade Gliomas: A Comparison of Preoperative Magnetic Resonance Imaging to Coregistered Intraoperative 3-Dimensional Ultrasound Recordings
    Munkvold, Bodil Karoline Ravn
    Bo, Hans Kristian
    Jakola, Asgeir Store
    Reinertsen, Ingerid
    Berntsen, Erik Magnus
    Unsgard, Geirmund
    Torp, Sverre Helge
    Solheim, Ole
    NEUROSURGERY, 2018, 83 (02) : 288 - 295
  • [33] Low-grade gliomas
    Schiff, David
    JOURNAL OF NEUROSURGERY, 2011, 115 (05) : 945 - 947
  • [34] Low-grade gliomas
    Stieber V.W.
    Current Treatment Options in Oncology, 2001, 2 (6) : 495 - 506
  • [35] Magnetic resonance perfusion for differentiating low-grade from high-grade gliomas at first presentation
    Abrigo, Jill M.
    Fountain, Daniel M.
    Provenzale, James M.
    Law, Eric K.
    Kwong, Joey S. W.
    Hart, Michael G.
    Tam, Wilson Wai San
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2018, (01):
  • [36] Physiologic and metabolic magnetic resonance imaging in gliomas
    Cao, Y
    Sundgren, PC
    Tsien, CI
    Chenevert, TT
    Junck, L
    JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (08) : 1228 - 1235
  • [37] Proton magnetic resonance spectroscopic imaging of pediatric low-grade astrocytomas
    Lazareff, JA
    Olmstead, C
    Bockhorst, KHJ
    Alger, JR
    CHILDS NERVOUS SYSTEM, 1996, 12 (03) : 130 - 135
  • [38] Extension of diffuse low-grade gliomas beyond radiological borders as shown by the coregistration of histopathological and magnetic resonance imaging data
    Zetterling, Maria
    Roodakker, Kenney R.
    Berntsson, Shala Ghaderi
    Edqvist, Per-Henrik
    Latini, Francesco
    Landtblom, Anne-Marie
    Ponten, Fredrik
    Alafuzoff, Irina
    Larsson, Elna-Marie
    Smits, Anja
    JOURNAL OF NEUROSURGERY, 2016, 125 (05) : 1155 - 1166
  • [39] Three-dimensional magnetic resonance imaging of fetal brains
    Schierlitz, L
    Dumanli, H
    Robinson, JN
    Burrows, PE
    Schreyer, AG
    Kikinis, R
    Jolesz, FA
    Tempany, MCM
    LANCET, 2001, 357 (9263): : 1177 - 1178
  • [40] Three-Dimensional Magnetic Resonance Imaging in the Musculoskeletal System
    Ahlawat, Shivani
    Kumar, Neil M.
    Ghasemi, Ali
    Fayad, Laura M.
    INVESTIGATIVE RADIOLOGY, 2025, 60 (03) : 184 - 197