Reflection time-of-flight mass spectrometer for charge-transfer cross section measurements

被引:7
|
作者
Wang, JB
Kwong, VHS
机构
[1] Department of Physics, University of Nevada, Las Vegas, Las Vegas
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1997年 / 68卷 / 10期
关键词
D O I
10.1063/1.1148014
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new method is described that combines the production of ions by laser ablation with a reflection time-of-flight mass spectrometer for charge-transfer cross section measurements. This method allows a specific charge-transfer channel of an ion-neutral pair to be measured at energies of about 0.1 keV/amu. The metastable state ion fraction in the laser ablation ion beam is shown to be negligible. The charge-transfer cross section is determined by measuring the intensity ratio of the product ions to the parent ions after the charge-transfer reactions occur in the reflection drift tube. Verification on the apparatus is demonstrated through investigation of a single electron charge transfer of ground state C2+ ions and H-2 with the incident energy of C2+ at 3045.6(sigma=12.4) eV. Our measured cross section of 6.90(+/- 0.78) x 10(-16) cm(-2) is consistent with ground state measurements reported previously. Because of the versatility of the pulsed laser ablation ion source, this facility can be used to examine the cross sections of a variety of multiply charged ions from refractory or gaseous elements. (C) 1997 American Institute of Physics.
引用
收藏
页码:3712 / 3717
页数:6
相关论文
共 50 条
  • [31] A NEW TIME-OF-FLIGHT MASS-SPECTROMETER
    SAKURAI, T
    FUJITA, Y
    MATSUO, T
    MATSUDA, H
    KATAKUSE, I
    MISEKI, K
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1985, 66 (03): : 283 - 290
  • [32] A design for a compact time-of-flight mass spectrometer
    Manard, Manuel J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [33] A TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    JARDINE, DR
    MORGAN, J
    ALDERDICE, DS
    DERRICK, PJ
    ORGANIC MASS SPECTROMETRY, 1992, 27 (10): : 1077 - 1083
  • [34] TIME-OF-FLIGHT MASS SPECTROMETER WITH IMPROVED RESOLUTION
    WILEY, WC
    MCLAREN, IH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1955, 26 (12): : 1150 - 1157
  • [35] Time-of-flight mass spectrometer with improved resolution
    Karas, M
    JOURNAL OF MASS SPECTROMETRY, 1997, 32 (01): : 1 - 3
  • [36] A TIME-OF-FLIGHT MASS SPECTROMETER WITH VARYING FIELD
    HIPPLE, JA
    THOMAS, HA
    PHYSICAL REVIEW, 1949, 75 (10): : 1616 - 1616
  • [37] TANDEM TIME-OF-FLIGHT MASS-SPECTROMETER
    CORNISH, TJ
    COTTER, RJ
    ANALYTICAL CHEMISTRY, 1993, 65 (08) : 1043 - 1047
  • [38] A cylindrical reflectron time-of-flight mass spectrometer
    Vialle, JL
    Baguenard, B
    Bourgey, A
    Cottancin, E
    Lerme, J
    Palpant, B
    Pellarin, M
    Valadier, F
    Broyer, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (06): : 2312 - 2318
  • [39] A time-of-flight mass spectrometer to resolve isobars
    Ishida, Y
    Wada, M
    Matsuo, Y
    Tanihata, I
    Casares, A
    Wollnik, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 219 : 468 - 472
  • [40] A NEW TIME-OF-FLIGHT MASS-SPECTROMETER
    SU, CS
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 220 (2-3): : 431 - 432