This paper gives a survey of problems of ultrasonic distance measurement systems with regard to applicability in Industrial environment as well as for presence detection and also for high resolution measurement tasks. The Impulse compression method is able to handle the mentioned problems. To simplify the real time signal processing a one bit correlation technique Is introduced. Next the comparison between A-B-measurement and use of passive reflection leads to a new method of active reflection in ultrasonic systems which combines the advantages of both methods. The active and passive reflection is compared and their common and different aspects are shown. In the following the radiation pattern of an ultrasonic transducer is analyzed and its influence to broadband signal emission and reception in conjunction with correlation based receivers is discussed. A prototype of an active reflection system is presented and Its final configuration is shown.
引用
收藏
页码:1565 / 1570
页数:6
相关论文
共 50 条
  • [41] High-Resolution Measurement Method Based on Array FOV and Coded Apertures
    Li Zhang
    Xing, Fei
    [J]. 2021 IEEE 16TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (NEMS), 2021, : 382 - 385
  • [42] Using coded signals to benefit from ultrasonic sensor crosstalk in mobile robot obstacle avoidance
    Shoval, S
    Borenstein, J
    [J]. 2001 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, 2001, : 2879 - 2884
  • [43] Accuracy and resolution of ultrasonic distance measurement with high-time-resolution cross-correlation function obtained by single-bit signal processing
    Hirata, Shinnosuke
    Kurosawa, Minoru Kuribayashi
    Katagiri, Takashi
    [J]. ACOUSTICAL SCIENCE AND TECHNOLOGY, 2009, 30 (06) : 429 - 438
  • [44] Research of Ultrasonic Distance Measurement Device
    Zhang Shaoyong
    [J]. 2010 6TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS NETWORKING AND MOBILE COMPUTING (WICOM), 2010,
  • [45] Effect of External Factors on Accuracy of Distance Measurement using Ultrasonic Sensors
    Singh, Navya Amin
    Borschbach, Markus
    [J]. 2017 INTERNATIONAL CONFERENCE ON SIGNALS AND SYSTEMS (ICSIGSYS), 2017, : 266 - 271
  • [46] High resolution air-coupled ultrasonic imaging of thin materials
    Gan, TH
    Hutchins, DA
    Billson, DR
    Schindel, DW
    [J]. 2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 897 - 900
  • [47] HIGH-RESOLUTION ULTRASONIC-IMAGING BY CONTROLLED AVERAGING OF BACKSCATTERED SIGNALS
    FAY, B
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (05): : 467 - 472
  • [48] Design of 3-D mouse using ultrasonic distance measurement
    Peng, G
    Xiong, CS
    Huang, XH
    Wang, M
    [J]. INTERNATIONAL CONFERENCE ON SENSORS AND CONTROL TECHNIQUES (ICSC 2000), 2000, 4077 : 226 - 229
  • [49] Computerized Kymograph for Muscle Contraction Measurement Using Ultrasonic Distance Sensor
    Suhaeri
    Tundjungsari, Vitri
    [J]. INTERNATIONAL JOURNAL OF ADVANCED COMPUTER SCIENCE AND APPLICATIONS, 2014, 5 (01) : 39 - 45
  • [50] Acoustic impedance measurement using PLSR based analysis of ultrasonic signals
    Schaefer, R
    Hauptmann, P
    [J]. 2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 178 - 181