Analysing on Characteristics of Lightning Shielding Failure of UHVAC Double Circuit Transmission Line Based on Leader Progression Method

被引:0
|
作者
Wang, Zhiyong [1 ]
Wang, Shaoan [2 ]
Yu, Zhanqing [2 ]
Geng, Yinan [2 ]
Zeng, Rong [2 ]
He, Jinliang [2 ]
Li, Zhizhao [2 ]
机构
[1] China Southern Power Grid Co LTD, Guangzhou Power Supply Bur, Guangzhou 510620, Guangdong, Peoples R China
[2] Tsinghua Univ, State Key Lab Control & Simulat Power Syst & Gene, Dept Elect Engn, Beijing 100084, Peoples R China
关键词
STROKES; GAPS;
D O I
10.1109/APEMC.2010.5475688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Shielding failure of lightning is the key problem for safe operation of UHV transmission lines. Taking the feature of 1000KV AC double circuit transmission lines into account, the leader progression method with proper criterion was employed. The lightning shielding failure rate of top phase, middle phase and bottom phase of two different transmission line tower types were compute, in three different geography conditions. The research work is helpful for improving the lightning performance of UHV transmission lines.
引用
收藏
页码:1582 / 1585
页数:4
相关论文
共 50 条
  • [11] Estimation of shielding failure number of different configurations of double-circuit transmission lines using leader progression analysis model
    Yahyaabadi, M.
    Vahidi, B.
    Tavakoli, M. R. Bank
    ELECTRICAL ENGINEERING, 2010, 92 (02) : 79 - 85
  • [12] Estimation of shielding failure number of different configurations of double-circuit transmission lines using leader progression analysis model
    M. Yahyaabadi
    B. Vahidi
    M. R. Bank Tavakoli
    Electrical Engineering, 2010, 92 : 79 - 85
  • [13] Lightning Shielding Protection Design and Actualization of 1000-kV UHVAC Overhead Transmission Line in China
    Yuan, Jun
    Yu, Zhanqing
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 1578 - 1581
  • [14] Modeling of Lightning Shielding Failure in UHV Transmission Line Based on Randomness Theory
    Fu, Jin
    Yang, Qing
    Sima, Wenxia
    Li, Jianbiao
    Xie, Bo
    ICHVE 2008: 2008 INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION, 2008, : 305 - 308
  • [15] Lightning shielding failure protection of the strained angled tower of double circuit UHV AC transmission lines
    He H.
    Chen W.
    Yin Y.
    Ge D.
    Zhang C.
    He J.
    Gaodianya Jishu/High Voltage Engineering, 2016, 42 (11): : 3448 - 3455
  • [16] Shielding-failure protective effect of sideward rod on tower crossarm of UHVAC transmission line
    Yu J.
    Zhou H.
    1600, Electric Power Automation Equipment Press (36): : 47 - 52
  • [17] An Analytical Method for Estimation of Lightning Performance of Transmission Lines Based on a Leader Progression Model
    Sima, Wenxia
    Li, Yongfu
    Rakov, Vladimir A.
    Yang, Qing
    Yuan, Tao
    Yang, Ming
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (06) : 1530 - 1539
  • [18] Numeral analysis model for shielding failure of transmission line under lightning stroke
    He, JL
    Tu, YP
    Zeng, R
    Lee, JB
    Chang, SH
    Guan, ZC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 815 - 822
  • [20] Assessment of Lightning Shielding Performance of Double-Circuit UHV Overhead Transmission Lines
    He, Hengxin
    He, Junjia
    Xie, ShiJun
    Yao, Shuai
    Zhang, Dandan
    Dong, Manling
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,