Experimental study on the loosening of pedicle screws implanted to synthetic bone vertebra models and under non-pull-out mechanical loads

被引:23
|
作者
Nowak, Bartosz [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Private Bag 4800, Christchurch 8140, New Zealand
关键词
Synthetic bones; Vertebra model; Spine implants; Pedicle screw; Screw loosening; SPINAL FIXATION; STRENGTH; BIOMECHANICS;
D O I
10.1016/j.jmbbm.2019.06.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Pull-out tests have been widely applied to orthopaedic devices such as pedicle screws for the last decades. Despite their wide applicability, this particular pedicle screw testing method does not represent the load pattern of implanted vertebrae with the use of pedicle screw spinal constructs. Purpose: In the present study a new custom made foam model (Sawbone) of human vertebra and a corresponding load pattern for pedicle screw spinal implant construct were introduced. They allow for the investigation of loosening at the bone-screw interface and constitute an alternative test method to pullout tests. Methods: The new custom made foam model of human vertebra was developed and made out of biomechanical materials Sawbones in three different variants, including varied density in order to simulate normal, osteopenic, and osteoporotic quality of bone. Mechanical testing methods followed reproducible, non-pull-out loading protocols based originally on the ASTM F- 1717 standard which enables to introduce loosening at the bone-screw interface. Results: The results include the pattern of screw loosening at the bone-screw interface, measured loosening area at the interface, and mechanical parameters characterising bone-screw interface such as initial stiffness and residual displacements. Conclusions: The new custom made foam model of human vertebra followed by non-pull-out load protocol enabled investigations of the loosening at the bone-screw interface. During the tests a characteristic toggling profile of loosening was found with a significant widening at the tip of the screw for the osteoporotic quality of bone. It was proposed that the model and the corresponding load protocol may extend the current testing methods based on the pull-out testing, leading to the more accurate testing of pedicle screw spinal constructs focused on the bone-implant interface.
引用
收藏
页码:200 / 204
页数:5
相关论文
共 12 条
  • [1] Effect of Insertional Direction of Pedicle Screw on Screw Loosening: A Biomechanical Study on Synthetic Bone Vertebra under a Physiology-like Load
    Zhan, Xuqiang
    Gao, Feng
    Yang, Yangyang
    Tsai, Tsung-Yuan
    Wan, Zongmiao
    Yu, Yan
    ORTHOPAEDIC SURGERY, 2024, 16 (06) : 1461 - 1472
  • [2] A Finite Element Analysis Based Sensitivity Studies on Pull Out Strength of Pedicle Screw in Synthetic Osteoporotic Bone Models
    Varghese, Vicky
    Kumar, G. Saravana
    Venkatesh, K.
    2016 IEEE EMBS CONFERENCE ON BIOMEDICAL ENGINEERING AND SCIENCES (IECBES), 2016, : 382 - 387
  • [3] Pull-out forces of headless compression screws in variations of synthetic bone models imitating different types of scaphoid fractures in good bone quality
    Jochen Erhart
    Ewald Unger
    Inga Trulson
    Michael Hagmann
    Robin Ristl
    Alexander Trulson
    Stefan Hajdu
    Philip Schefzig
    Anna Gormasz
    Winfried Mayr
    Journal of Materials Science: Materials in Medicine, 2020, 31
  • [4] Pull-out forces of headless compression screws in variations of synthetic bone models imitating different types of scaphoid fractures in good bone quality
    Erhart, Jochen
    Unger, Ewald
    Trulson, Inga
    Hagmann, Michael
    Ristl, Robin
    Trulson, Alexander
    Hajdu, Stefan
    Schefzig, Philip
    Gormasz, Anna
    Mayr, Winfried
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2020, 31 (11)
  • [5] A bicortical pedicle screw in the caudad trajectory is the best option for the fixation of an osteoporotic vertebra: An in-vitro experimental study using synthetic lumbar osteoporotic bone models
    Shibasaki, Yasuyuki
    Tsutsui, Shunji
    Yamamoto, Ei
    Murakami, Kimihide
    Yoshida, Munehito
    Yamada, Hiroshi
    CLINICAL BIOMECHANICS, 2020, 72 : 150 - 154
  • [6] Does the anchorage form and depth influence the pull-out strength of screws from bone cement?An experimental study
    K. -D. Heller
    K. W. Zilkens
    J. Hammer
    B. Cohen
    Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 88 - 91
  • [7] Does the anchorage form and depth influence the pull-out strength of screws from bone cement? An experimental study
    Heller, KD
    Zilkens, KW
    Hammer, J
    Cohen, B
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (1-2) : 88 - 91
  • [8] Experimental study on spatial mechanical behavior of CFST arch under non-directional loads
    Wei J.
    Ping J.
    Chen L.
    Wu Q.
    Chen B.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2017, 38 : 451 - 456
  • [9] Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone
    Ovesy, Marzieh
    Silva-Henao, Juan Diego
    Fletcher, James W.A.
    Gueorguiev, Boyko
    Zysset, Philippe K.
    Varga, Peter
    Journal of the Mechanical Behavior of Biomedical Materials, 2022, 126
  • [10] Non-linear explicit micro-FE models accurately predict axial pull-out force of cortical screws in human tibial cortical bone
    Ovesy, Marzieh
    Silva-Henao, Juan Diego
    Fletcher, James W. A.
    Gueorguiev, Boyko
    Zysset, Philippe K.
    Varga, Peter
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 126