Comparison of Direct and Digital Measures of Cranial Vault Asymmetry for Assessment of Plagiocephaly

被引:30
|
作者
Skolnick, Gary B. [1 ]
Naidoo, Sybill D. [1 ]
Nguyen, Dennis C. [1 ]
Patel, Kamlesh B. [1 ]
Woo, Albert S. [1 ]
机构
[1] Washington Univ, Sch Med, Div Plast & Reconstruct Surg, Dept Surg,Cleft Palate Craniofacial Inst, St Louis, MO 63110 USA
关键词
Cranial vault asymmetry; deformational plagiocephaly; photogrammetry; ANTHROPOMETRIC MEASUREMENTS; ORTHOTIC CRANIOPLASTY; MANAGEMENT; INFANTS; RELIABILITY; DEFORMITIES; ACCURACY; THERAPY; HELMET; SHAPE;
D O I
10.1097/SCS.0000000000002019
中图分类号
R61 [外科手术学];
学科分类号
摘要
Measurement of cranial vault asymmetry (CVA) is a common feature in the treatment of patients with deformational plagiocephaly (DP). In many cases, this measure is the primary marker of improvement. CVA is typically measured with calipers and is subject to interrater variability. There is little research comparing results of calipers with those of three-dimensional (3D) photogrammetry.Fifty nine visits were made by 51 children previously diagnosed with DP. Thirty eight were male and 13 were female. Thirty one of the visits included a 3D photograph. Direct measures were obtained by 2 experienced anthropometrists and included head length, width, circumference, and CVA. Their results were compared to digital measures including measures unobtainable with calipers, asymmetry of head circumference and global asymmetry.The interrater reliability of all caliper measures was excellent (intraclass correlation coefficients>0.94). Caliper and digital measures of length, width, cephalic index, and circumference were strongly correlated (R-2>0.90). There was a consistent bias, caliper measures being 1 to 4mm shorter than their digital analogues. Caliper measured CVA was highly correlated (R-2>0.90) with the directly corresponding digital measures. It was poorly correlated with measures of overall hemispheric asymmetry (R-2<0.10).The cranial measurements of children with DP taken independently by 2 experienced anthropometrists showed excellent interrater reliability. Caliper measures are consistently smaller than the digital measures, presumably due to pressure of the calipers and/or the use of skullcaps during photography. Like circumference and other assessments, cranial vault asymmetry measures correlate well with their analogous digital measurements.
引用
收藏
页码:1900 / 1903
页数:4
相关论文
共 50 条
  • [31] Posterior cranial vault expansion in the treatment of craniosynostosis. Comparison of current techniques
    Nowinski, Daniel
    Di Rocco, Federico
    Renier, Dominique
    SainteRose, Christian
    Leikola, Junnu
    Arnaud, Eric
    CHILDS NERVOUS SYSTEM, 2012, 28 (09) : 1537 - 1544
  • [32] A Physician-Centered Craniofacial Asymmetry Index for the Severity of Plagiocephaly A Comparative Study of Assessment Methods
    Lee, Chien-Han
    Lin, Ting-Hsuan
    Chen, Shih-Heng
    Chen, Meng-Tse
    Chen, Pin-Ru
    Shih, Albert J.
    Lee, Chang-Chun
    Chou, Pang-Yun
    ANNALS OF PLASTIC SURGERY, 2025, 94 (04) : 462 - 467
  • [33] A Comparison of Subgaleal Versus Subperiosteal Dissection in Open Cranial Vault Expansion for Sagittal Craniosynostosis
    Cho, Daniel Y.
    Birgfeld, Craig B.
    Lee, Amy
    Ellenbogen, Richard G.
    Susarla, Srinivas M.
    WORLD NEUROSURGERY, 2020, 143 : 108 - 113
  • [34] Comparison of a modifiable cranial cup versus repositioning and cervical stretching for the early correction of deformational posterior plagiocephaly
    Rogers, Gary F.
    Miller, James
    Mulliken, John B.
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2008, 121 (03) : 941 - 947
  • [35] Increased Incidence of Ophthalmologic Findings in Children With Concurrent Isolated Nonsyndromic Metopic Suture Abnormalities and Deformational Cranial Vault Asymmetry
    Roider, Laura
    Ungerer, Garrett
    Shock, Leslie
    Aldridge, Kristina
    Al-Samarraie, Mohannad
    Tanaka, Tomoko
    Muzaffar, Arshad
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 2021, 58 (04): : 497 - 504
  • [36] Three-Dimensional versus Two-Dimensional Evaluations of Cranial Asymmetry in Deformational Plagiocephaly Using a Three-Dimensional Scanner
    Kato, Risa
    Nagano, Nobuhiko
    Hashimoto, Shin
    Saito, Katsuya
    Miyabayashi, Hiroshi
    Noto, Takanori
    Morioka, Ichiro
    CHILDREN-BASEL, 2022, 9 (06):
  • [37] Analysis of clinical outcomes for treatment of sagittal craniosynostosis: a comparison of endoscopic suturectomy and cranial vault remodeling
    Isaac, Kathryn, V
    Meara, John G.
    Proctor, Mark R.
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2018, 22 (05) : 467 - 474
  • [38] Perioperative Comparison Between Open Cranial Vault Remodeling and Distraction Osteogenesis for Unilateral Lambdoid Craniosynostosis
    Belza, Caitlyn C.
    Modi, Rishi N.
    Kamel, George N.
    McKee, Ryan M.
    Carbullido, Mary K.
    Kim, Erinn
    Gosman, Amanda A.
    JOURNAL OF CRANIOFACIAL SURGERY, 2023, 34 (04) : 1222 - 1225
  • [39] THE ESTIMATION OF CRANIAL CAPACITY A COMPARISON OF THE DIRECT WATER AND SEED METHODS
    Todd, T. Wingate
    Kuenzel, Wilhelmine
    AMERICAN JOURNAL OF PHYSICAL ANTHROPOLOGY, 1925, 8 (03) : 251 - 259
  • [40] A comparison of similarity measures for digital subtraction radiography
    Lehmann, T
    Sovakar, A
    Schmitt, W
    Repges, R
    COMPUTERS IN BIOLOGY AND MEDICINE, 1997, 27 (02) : 151 - 167