Investigation on Non-invasive Current Mismatch Measurement in Paralleled GaN HEMTs

被引:3
|
作者
Lauer, A. [2 ]
Niakan, H. [1 ]
Hiller, M. [2 ]
Parkhideh, B. [1 ]
机构
[1] Univ North Carolina Charlotte, Elect & Comp Engn Dept, Energy Prod & Infrastruct Ctr EPIC, Charlotte, NC USA
[2] Karlsruhe Inst Technol, Electrotech Inst ETI, Power Elect Syst, Karlsruhe, Germany
基金
美国国家科学基金会;
关键词
Current measurement; GaN HEMTs; magneto-resistor; two-dimensional electron gas (2DEG); wide bandgap; CURRENT SENSOR;
D O I
10.23919/icpe2019-ecceasia42246.2019.8797099
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
On the recent advancements in current sensor field, single chip contactless current sensors enable the end users to efficiently monitor the switching current in modern power electronics systems. This work further investigates a novel low-cost measurement technique based on Magneto-resistive (MR) sensors. The process uses a single current sensing unit, measuring the current mismatch between the two parallel Gallium Nitride (GaN) MOSFETs, which would be used for prognostic and protection purposes. The magnetic field distribution analysis of GaN devices in switching converter is investigated using FEA simulations, in order to optimize the MR sensor location. The experimental results verify the sensitivity and linearity of the sensing unit up to 20 A of current mismatch.
引用
收藏
页码:899 / 904
页数:6
相关论文
共 50 条
  • [21] Non-invasive ventilation: current status
    Khilnani, GC
    Bhatta, N
    NATIONAL MEDICAL JOURNAL OF INDIA, 2002, 15 (05): : 269 - 274
  • [22] Non-invasive uroflow measurement in mice
    Leung, YYM
    Wood, RW
    Schwarz, E
    Messing, EM
    JOURNAL OF UROLOGY, 2004, 171 (04): : 451 - 451
  • [23] NON-INVASIVE CARDIOVASCULAR METHODS OF MEASUREMENT
    DENGLER, HJ
    BOCK, KD
    RUTISHAU.W
    RAHN, KH
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1973, 23 (8A): : 1176 - 1177
  • [24] Non-invasive measurement of intracranial pressure
    Hartmann, A
    LANCET, 1998, 351 (9101): : 524 - 524
  • [25] Managing non-invasive measurement tools
    Sillitti, Alberto
    Succi, Giancarlo
    De Panfilis, Stefano
    JOURNAL OF SYSTEMS ARCHITECTURE, 2006, 52 (11) : 676 - 683
  • [26] Non-invasive measurement of the kinematics of the clavicle
    Marchese, SS
    Johnson, GR
    PROCEEDINGS OF THE THIRD CONFERENCE OF THE INTERNATIONAL SHOULDER GROUP, 2001, : 61 - 65
  • [27] An Architecture for Non-invasive Software Measurement
    Artemev, Vasilii
    Ivanov, Vladimir
    Mazzara, Manuel
    Rogers, Alan
    Sillitti, Alberto
    Succi, Giancarlo
    Zouev, Eugene
    PERSPECTIVES OF SYSTEM INFORMATICS, PSI 2017, 2018, 10742 : 1 - 11
  • [28] Non-invasive measurement of corneal hydration
    March, WF
    Bauer, NJC
    JOURNAL OF REFRACTIVE SURGERY, 2001, 17 (02) : S205 - S210
  • [29] NON-INVASIVE MEASUREMENT OF STOMACH MOTILITY
    BERGMANN, H
    STACHER, G
    HAVLIK, E
    HOFER, R
    ACTA MEDICA AUSTRIACA, 1982, 9 : 114 - 114
  • [30] Non-invasive Measurement of Portal Pressure
    Elmahdy A.M.