Development of nuclear diagnostics for the National Ignition Facility (invited)

被引:80
|
作者
Glebov, V. Yu. [1 ]
Meyerhofer, D. D.
Sangster, T. C.
Stoeckl, C.
Roberts, S.
Barrera, C. A.
Celeste, J. R.
Cerjan, C. J.
Dauffy, L. S.
Eder, D. C.
Griffith, R. L.
Haan, S. W.
Hammel, B. A.
Hatchett, S. P.
Izumi, N.
Kimbrough, J. R.
Koch, J. A.
Landen, O. L.
Lerche, R. A.
MacGowan, B. J.
Moran, M. J.
Ng, E. W.
Phillips, T. W.
Song, P. M.
Tommasini, R.
Young, B. K.
Caldwell, S. E.
Grim, G. P.
Evans, S. C.
Mack, J. M.
Sedillo, T. J.
Wilke, M. D.
Wilson, D. C.
Young, C. S.
Casey, D.
Frenje, J. A.
Li, C. K.
Petrasso, R. D.
Seguin, F. H.
Bourgade, J. L.
Disdier, L.
Houry, M.
Lantuejoul, I.
Landoas, O.
Chandler, G. A.
Cooper, G. W.
Leeper, R. J.
Olson, R. E.
Ruiz, C. L.
Sweeney, M. A.
机构
[1] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[4] MIT, Plasma Sci & Fus Ctr, Cambridge, MA 02139 USA
[5] CEA, DAM, F-91680 Bruyeres Le Chatel, France
[6] Sandia Natl Labs, Albuquerque, NM 87185 USA
[7] SUNY Coll Geneseo, Geneseo, NY 14454 USA
[8] Atom Weapons Etab, Reading RG7 4PR, Berks, England
[9] Natl Secur Technol, Las Vegas, NV 89030 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 10期
关键词
D O I
10.1063/1.2236281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Ignition Facility (NIF) will provide up to 1.8 MJ of laser energy for imploding inertial confinement fusion (ICF) targets. Ignited NIF targets are expected to produce up to 1019 DT neutrons. This will provide unprecedented opportunities and challenges for the use of nuclear diagnostics in ICF experiments. In 2005, the suite of nuclear-ignition diagnostics for the NIF was defined and they are under development through collaborative efforts at several institutions. This suite includes PROTEX and copper activation for primary yield measurements, a magnetic recoil spectrometer and carbon activation for fuel areal density, neutron time-of-flight detectors for yield and ion temperature, a gamma bang time detector, and neutron imaging systems for primary and downscattered neutrons. An overview of the conceptual design, the developmental status, and recent results of prototype tests on the OMEGA laser will be presented. (c) 2006 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Debris and shrapnel assessments for National Ignition Facility targets and diagnostics
    Masters, N. D.
    Fisher, A.
    Kalantar, D.
    Stolken, J.
    Smith, C.
    Vignes, R.
    Burns, S.
    Doeppner, T.
    Kritcher, A.
    Park, H-S
    9TH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS (IFSA 2015), 2016, 717
  • [22] Solid debris collection for radiochemical diagnostics at the National Ignition Facility
    Gostic, J. M.
    Shaughnessy, D. A.
    Moore, K. T.
    Hutcheon, I. D.
    Grant, P. M.
    Moody, K. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [23] Solid debris collection for radiochemical diagnostics at the National Ignition Facility
    Gostic, Julie
    Shaughnessy, Dawn
    Greife, Uwe
    Grant, Pat
    Hutcheon, Ian
    Lewis, Laurence
    Grim, Gary
    Rundberg, Robert
    Moody, Kenton
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2011, 242
  • [24] Diagnostics on the National Ignition Facility have built the user community
    Kilkenny, Joe
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 248
  • [25] Digitizer Architecture Analysis for Target Diagnostics on the National Ignition Facility
    Carpenter, A. C.
    Clancy, T. J.
    Beeman, B.
    Bell, P.
    TARGET DIAGNOSTICS PHYSICS AND ENGINEERING FOR INERTIAL CONFINEMENT FUSION IV, 2015, 9591
  • [26] Target diagnostic control system implementation for the National Ignition Facility (invited)
    Shelton, R. T.
    Kamperschroer, J. H.
    Lagin, L. J.
    Nelson, J. R.
    O'Brien, D. W.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [27] National Ignition Facility neutron time-of-flight measurements (invited)
    Lerche, R. A.
    Glebov, V. Yu.
    Moran, M. J.
    McNaney, J. M.
    Kilkenny, J. D.
    Eckart, M. J.
    Zacharias, R. A.
    Haslam, J. J.
    Clancy, T. J.
    Yeoman, M. F.
    Warwas, D. P.
    Sangster, T. C.
    Stoeckl, C.
    Knauer, J. P.
    Horsfield, C. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [28] Target area and diagnostic interface issues on the National Ignition Facility (invited)
    Bell, P
    Lee, D
    Wootton, A
    Mascio, B
    Kimbrough, J
    Sewall, N
    Hibbard, W
    Dohoney, P
    Landon, M
    Christianson, G
    Celeste, J
    Chael, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 492 - 498
  • [29] Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)
    Bionta, R. M.
    Grim, G. P.
    Hahn, K. D.
    Hartouni, E. P.
    Henry, E. A.
    Khater, H. Y.
    Moore, A. S.
    Schlossberg, D. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (04):
  • [30] First look at neutron emission shape characteristics of ignition hotspots at the National Ignition Facility (invited)
    Durocher, Mora
    Geppert-Kleinrath, Verena
    Danly, Christopher R.
    Wilde, Carl H.
    Saavedra, Gary J.
    Freeman, Matthew S.
    Fatherley, Valerie E.
    Mendoza, Emily F.
    Tafoya, Landon R.
    Volegov, Petr L.
    Fittinghoff, David N.
    Rubery, Michael
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (09):