Development of nuclear diagnostics for the National Ignition Facility (invited)

被引:80
|
作者
Glebov, V. Yu. [1 ]
Meyerhofer, D. D.
Sangster, T. C.
Stoeckl, C.
Roberts, S.
Barrera, C. A.
Celeste, J. R.
Cerjan, C. J.
Dauffy, L. S.
Eder, D. C.
Griffith, R. L.
Haan, S. W.
Hammel, B. A.
Hatchett, S. P.
Izumi, N.
Kimbrough, J. R.
Koch, J. A.
Landen, O. L.
Lerche, R. A.
MacGowan, B. J.
Moran, M. J.
Ng, E. W.
Phillips, T. W.
Song, P. M.
Tommasini, R.
Young, B. K.
Caldwell, S. E.
Grim, G. P.
Evans, S. C.
Mack, J. M.
Sedillo, T. J.
Wilke, M. D.
Wilson, D. C.
Young, C. S.
Casey, D.
Frenje, J. A.
Li, C. K.
Petrasso, R. D.
Seguin, F. H.
Bourgade, J. L.
Disdier, L.
Houry, M.
Lantuejoul, I.
Landoas, O.
Chandler, G. A.
Cooper, G. W.
Leeper, R. J.
Olson, R. E.
Ruiz, C. L.
Sweeney, M. A.
机构
[1] Univ Rochester, Laser Energet Lab, Rochester, NY 14623 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[4] MIT, Plasma Sci & Fus Ctr, Cambridge, MA 02139 USA
[5] CEA, DAM, F-91680 Bruyeres Le Chatel, France
[6] Sandia Natl Labs, Albuquerque, NM 87185 USA
[7] SUNY Coll Geneseo, Geneseo, NY 14454 USA
[8] Atom Weapons Etab, Reading RG7 4PR, Berks, England
[9] Natl Secur Technol, Las Vegas, NV 89030 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2006年 / 77卷 / 10期
关键词
D O I
10.1063/1.2236281
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The National Ignition Facility (NIF) will provide up to 1.8 MJ of laser energy for imploding inertial confinement fusion (ICF) targets. Ignited NIF targets are expected to produce up to 1019 DT neutrons. This will provide unprecedented opportunities and challenges for the use of nuclear diagnostics in ICF experiments. In 2005, the suite of nuclear-ignition diagnostics for the NIF was defined and they are under development through collaborative efforts at several institutions. This suite includes PROTEX and copper activation for primary yield measurements, a magnetic recoil spectrometer and carbon activation for fuel areal density, neutron time-of-flight detectors for yield and ion temperature, a gamma bang time detector, and neutron imaging systems for primary and downscattered neutrons. An overview of the conceptual design, the developmental status, and recent results of prototype tests on the OMEGA laser will be presented. (c) 2006 American Institute of Physics.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Nuclear diagnostics for the National Ignition Facility (invited)
    Murphy, TJ
    Barnes, CW
    Berggren, RR
    Bradley, P
    Caldwell, SE
    Chrien, RE
    Faulkner, JR
    Gobby, PL
    Hoffman, N
    Jimerson, JL
    Klare, KA
    Lee, CL
    Mack, JM
    Morgan, GL
    Oertel, JA
    Swenson, FJ
    Walsh, PJ
    Walton, RB
    Watt, RG
    Wilke, MD
    Wilson, DC
    Young, CS
    Haan, SW
    Lerche, RA
    Moran, MJ
    Phillips, TW
    Sangster, TC
    Leeper, RJ
    Ruiz, CL
    Cooper, GW
    Disdier, L
    Rouyer, A
    Fedotoff, A
    Glebov, VY
    Meyerhofer, DD
    Soures, JM
    Stöckl, C
    Frenje, JA
    Hicks, DG
    Li, CK
    Petrasso, RD
    Seguin, FH
    Fletcher, K
    Padalino, S
    Fisher, RK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (01): : 773 - 779
  • [2] Neutron activation diagnostics at the National Ignition Facility (invited)
    Bleuel, D. L.
    Yeamans, C. B.
    Bernstein, L. A.
    Bionta, R. M.
    Caggiano, J. A.
    Casey, D. T.
    Cooper, G. W.
    Drury, O. B.
    Frenje, J. A.
    Hagmann, C. A.
    Hatarik, R.
    Knauer, J. P.
    Johnson, M. Gatu
    Knittel, K. M.
    Leeper, R. J.
    McNaney, J. M.
    Moran, M.
    Ruiz, C. L.
    Schneider, D. H. G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [3] The Radiochemical Analysis of Gaseous Samples (RAGS) apparatus for nuclear diagnostics at the National Ignition Facility (invited)
    Shaughnessy, D. A.
    Velsko, C. A.
    Jedlovec, D. R.
    Yeamans, C. B.
    Moody, K. J.
    Tereshatov, E.
    Stoeffl, W.
    Riddle, A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [4] Nuclear Diagnostics at the National Ignition Facility, 2013-2015
    Yeamans, C. B.
    Cassata, W. S.
    Church, J. A.
    Fittinghoff, D. N.
    Johnson, M. Gatu
    Gharibyan, N.
    Hatarik, R.
    Sayre, D. B.
    Sio, H. W.
    Bionta, R. M.
    Bleuel, D. L.
    Caggiano, J. A.
    Cerjan, C. J.
    Cooper, G. W.
    Eckart, M. J.
    Edwards, E. R.
    Faye, S. A.
    Forrest, C. J.
    Frenje, J. A.
    Glebov, V. Yu
    Grant, P. M.
    Grim, G. P.
    Hartouni, E. P.
    Herrmann, H. W.
    Kilkenny, J. D.
    Knauer, J. P.
    Mackinnon, A. J.
    Merrill, F. E.
    Moody, K. J.
    Moran, M. J.
    Petrasso, R. D.
    Phillips, T. W.
    Rinderknecht, H. G.
    Schneider, D. H. G.
    Sepke, S. M.
    Shaughnessy, D. A.
    Stoeffl, W.
    Velsko, C. A.
    Volegov, P.
    9TH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS (IFSA 2015), 2016, 717
  • [5] Radiochemical diagnostics at the National Ignition Facility
    Despotopulos, John D.
    Shaughnessy, Dawn A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (02):
  • [6] Prompt radiochemistry at the National Ignition Facility (invited)
    Grim, G. P.
    Bradley, P. A.
    Bredeweg, T. A.
    Keksis, A. L.
    Fowler, M. M.
    Hayes, A. C.
    Jungman, G.
    Obst, A. W.
    Rundberg, R. S.
    Vieira, D. J.
    Wilhelmy, J. B.
    Bernstein, L. A.
    Cerjan, C. J.
    Fortner, R. J.
    Moody, K. J.
    Schneider, D. H.
    Shaughnessy, D. A.
    Stoeffl, W.
    Stoyer, M. A.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2008, 79 (10):
  • [7] Radiochemical diagnostics for the national ignition facility.
    Stoyer, MA
    Hudson, GB
    Lougheed, RW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 10 - NUCL
  • [8] Neutron activation diagnostics at the National Ignition Facility
    Bleuel, Darren L.
    Yeamans, Charles
    Bernstein, Lee
    Bionta, Richard
    Cooper, G.
    Drury, Owen
    Hagmann, Chris
    Knittel, Kenn
    Leeper, Ray
    Ruiz, C.
    Schneider, Dieter
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [9] Target diagnostic system for the National Ignition Facility (invited)
    Leeper, RJ
    Chandler, GA
    Cooper, GW
    Derzon, MS
    Fehl, DL
    Hebron, DE
    Moats, AR
    Noack, DD
    Porter, JL
    Ruggles, LE
    Ruiz, CL
    Torres, JA
    Cable, MD
    Bell, PM
    Clower, CA
    Hammel, BA
    Kalantar, DH
    Karpenko, VP
    Kauffman, RL
    Kilkenny, JD
    Lee, FD
    Lerche, RA
    MacGowan, BJ
    Moran, MJ
    Nelson, MB
    Olson, W
    Orzechowski, TJ
    Phillips, TW
    Ress, D
    Tietbohl, GL
    Trebes, JE
    Bartlett, RJ
    Berggren, R
    Caldwell, SE
    Chrien, RE
    Failor, BH
    Fernandez, JC
    Hauer, A
    Idzorek, G
    Hockaday, RG
    Murphy, TJ
    Oertel, J
    Watt, R
    Wilke, M
    Bradley, DK
    Knauer, J
    Petrasso, RD
    Li, CK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01): : 868 - 879
  • [10] DIAGNOSTIC SYSTEMS FOR THE NATIONAL IGNITION FACILITY (NIF) (INVITED)
    KILKENNY, JD
    CABLE, MD
    CLOWER, CA
    HAMMEL, BA
    KARPENKO, VP
    KAUFFMAN, RL
    KORNBLUM, HN
    MACGOWAN, BJ
    OLSON, W
    ORZECHOWSKI, TJ
    PHILLION, DW
    TIETBOHL, GL
    TREBES, JE
    CHRIEN, B
    FAILOR, B
    HAUER, A
    HOCKADAY, R
    OERTEL, J
    WATT, R
    RUIZ, C
    COOPER, G
    HEBRON, D
    LEEPER, R
    PORTER, J
    KNAUER, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 288 - 295