Impedimetric Determination of Antiretroviral Drugs on a Modified Glassy Carbon Electrode

被引:0
|
作者
Chihava, Ruvimbo [1 ]
Moyo, Mambo [1 ]
Shumba, Munyaradzi [1 ]
机构
[1] Midlands State Univ, Dept Chem Technol, Sensor Lab Res Grp, Private Bag 9055, Senga, Gweru, Zimbabwe
来源
2018 IEEE SENSORS | 2018年
关键词
voltammetry; antiretroviral drugs; electrochemical impedance spectroscopy; LAMIVUDINE; TENOFOVIR; ZIDOVUDINE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An impedimetric sensor was fabricated for the determination of determination of lamivudine (LAM) and tenofivir disoproxil fumarate (TDF) using a modified glassy carbon electrode. The glassy carbon electrode was modified with nickel-cobalt sulfide decorated graphene quantum dots (Ni-CoS-GQDs). Characterization of the fabricated sensor was achieved by using UV-Vis, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The LODs were 56.18 mu g/ml, LAM and 56.13 gtg/ml, TDF. The average recovery range was 98.85%.
引用
收藏
页码:943 / 946
页数:4
相关论文
共 50 条
  • [31] Impedimetric immunosensor to determine patulin in apple juices using a glassy carbon electrode modified with graphene oxide
    Ivan Riberi, Walter
    Alicia Zon, Maria
    Fernandez, Hector
    Javier Arevalo, Fernando
    MICROCHEMICAL JOURNAL, 2020, 158
  • [32] Amperometric and impedimetric characterization of a glutamate biosensor based on Nafion® and a methyl viologen modified glassy carbon electrode
    Maalouf, Rita
    Chebib, Hanna
    Saikali, Youssef
    Vittori, Olivier
    Sigaud, Monique
    Jaffrezic-Renault, Nicole
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11): : 2682 - 2688
  • [33] Electrochemical determination of bisphenol A with a glassy carbon electrode modified with gold nanodendrites
    Chen, Wan-Yi
    Mei, Li-Ping
    Feng, Jiu-Ju
    Yuan, Tao
    Wang, Ai-Jun
    Yu, Haiying
    MICROCHIMICA ACTA, 2015, 182 (3-4) : 703 - 709
  • [34] Nafion-modified glassy carbon electrode for trace determination of indium
    Xiang, CL
    Zou, YJ
    Xie, JJ
    Fei, XM
    Li, JH
    ANALYTICAL LETTERS, 2005, 38 (13) : 2045 - 2055
  • [35] Mordant black modified glassy carbon electrode for the determination of methylene blue
    Bendany, Mohamed
    Ben Brahim, Khalid Ait
    El Hamdouni, Youssra
    Oumoussa, Hajar
    Labjar, Najoua
    Dahrouche, Abdelouahed
    Dalimi, Mohamed
    Omari, Mohamed
    Jebbari, Said
    Nasrellah, Hamid
    El Hajjaji, Souad
    EURO-MEDITERRANEAN JOURNAL FOR ENVIRONMENTAL INTEGRATION, 2024,
  • [36] Ruthenium Hexacyanoferrate (III) Modified Glassy Carbon Electrode for Determination of Captopril
    Dias, I. A. R. B.
    Costa, W. M.
    Cervini, P.
    Cavalheiro, E. T. G.
    Marques, A. L. B.
    ELECTROANALYSIS, 2016, 28 (09) : 2136 - 2142
  • [37] Simultaneous determination of levodopa and tryptophan using a modified glassy carbon electrode
    Aflatoonian, Mohammad Reza
    Tajik, Somayeh
    Aflatoonian, Behnaz
    Ekrami-Kakhki, Mehri-Saddat
    Divsalar, Kouros
    Shoaie, Iran Sheikh
    Dourandish, Zahra
    Sheikhshoaie, Mahdieh
    EURASIAN CHEMICAL COMMUNICATIONS, 2020, 2 (04): : 505 - 515
  • [38] ELECTROCHEMICAL DETERMINATION OF ETHYL MALTOL ON A GLASSY CARBON ELECTRODE MODIFIED WITH GRAPHENE
    Chen, Meifeng
    Ma, Xinying
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2013, 58 (03): : 1918 - 1920
  • [39] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Department of Pharmacy, Faculty of Medicine, University of Banja Luka, Save Mrkalja 14, Banja Luka
    78000, Bosnia and Herzegovina
    不详
    11000, Serbia
    不详
    11000, Serbia
    不详
    78000, Bosnia and Herzegovina
    Anal. Sci., 2 (353-358):
  • [40] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Lemma Teshome Tufa
    Khalid Siraj
    Tesfaye Refera Soreta
    Russian Journal of Electrochemistry, 2013, 49 : 59 - 66