Impedimetric Determination of Antiretroviral Drugs on a Modified Glassy Carbon Electrode

被引:0
|
作者
Chihava, Ruvimbo [1 ]
Moyo, Mambo [1 ]
Shumba, Munyaradzi [1 ]
机构
[1] Midlands State Univ, Dept Chem Technol, Sensor Lab Res Grp, Private Bag 9055, Senga, Gweru, Zimbabwe
来源
关键词
voltammetry; antiretroviral drugs; electrochemical impedance spectroscopy; LAMIVUDINE; TENOFOVIR; ZIDOVUDINE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An impedimetric sensor was fabricated for the determination of determination of lamivudine (LAM) and tenofivir disoproxil fumarate (TDF) using a modified glassy carbon electrode. The glassy carbon electrode was modified with nickel-cobalt sulfide decorated graphene quantum dots (Ni-CoS-GQDs). Characterization of the fabricated sensor was achieved by using UV-Vis, electrochemical impedance spectroscopy (EIS), cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The LODs were 56.18 mu g/ml, LAM and 56.13 gtg/ml, TDF. The average recovery range was 98.85%.
引用
收藏
页码:943 / 946
页数:4
相关论文
共 50 条
  • [1] Impedimetric pyrene determination at fMWCNTs/CuO-ZnO modified glassy carbon electrode
    Funmilola A. Adesanya
    Omolola E. Fayemi
    Discover Applied Sciences, 7 (5)
  • [2] Amperometric and Impedimetric Determination of Hydrazine at a Novel Trimethine Cyanine Dye Film Modified Glassy Carbon Electrode
    Wei, Jia-Xuan
    Periasamy, Arun Prakash
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (07): : 2411 - 2428
  • [3] Impedimetric aptasensor for Pseudomonas aeruginosa by using a glassy carbon electrode modified with silver nanoparticles
    Mahmoud Roushani
    Masoumeh Sarabaegi
    Fazal Pourahmad
    Microchimica Acta, 2019, 186
  • [4] Voltammetric Determination of Arsenic with Modified Glassy Carbon Electrode
    Stankovic, Anamarija
    Kajinic, Zana
    Turkalj, Jelena Vesligaj
    Romic, Zeljka
    Sikiric, Maja Dutour
    Asserghine, Abdelilah
    Nagy, Geza
    Medvidovic-Kosanovic, Martina
    ELECTROANALYSIS, 2020, 32 (05) : 1043 - 1051
  • [5] Impedimetric aptasensor for Pseudomonas aeruginosa by using a glassy carbon electrode modified with silver nanoparticles
    Roushani, Mahmoud
    Sarabaegi, Masoumeh
    Pourahmad, Fazal
    MICROCHIMICA ACTA, 2019, 186 (11)
  • [6] Polyglycine Modified Glassy Carbon Electrode for Ibuprofen Determination
    Matijasevic, Igor
    Kulizic, Mihajlo
    Bacetic, Ljubica
    Gavrilovic, Damjan
    Baosic, Rada
    Lolic, Aleksandar
    CHEMISTRYSELECT, 2023, 8 (24):
  • [7] Determination of ethambutol at glassy carbon electrode modified with multiwall carbon nanotubes
    Shao, Chen
    Wei, Yingliang
    Li, Shumian
    Li, Chao
    CHEMIA ANALITYCZNA, 2008, 53 (04): : 511 - 521
  • [8] A glassy carbon electrode modified with carbon nanoonions for electrochemical determination of fentanyl
    Sohouli, Esmail
    Keihan, Amir Homayoun
    Shahdost-fard, Faezeh
    Naghian, Ebrahim
    Plonska-Brzezinska, Marta E.
    Rahimi-Nasrabadi, Mehdi
    Ahmadi, Farhad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2020, 110
  • [9] An impedimetric aptasensor for Shigella dysenteriae using a gold nanoparticle-modified glassy carbon electrode
    Seyed Sanaan Zarei
    Sabihe Soleimanian-Zad
    Ali A. Ensafi
    Microchimica Acta, 2018, 185
  • [10] An aptasensor for voltammetric and impedimetric determination of cocaine based on a glassy carbon electrode modified with platinum nanoparticles and using rutin as a redox probe
    Mahmoud Roushani
    Faezeh Shahdost-fard
    Microchimica Acta, 2016, 183 : 185 - 193