Sol-gel based metal-organic framework zeolite imidazolate framework-8 fibers for solid-phase microextraction of nitro polycyclic aromatic hydrocarbons and polycyclic aromatic hydrocarbons in water samples

被引:64
|
作者
Kong, Jijie [1 ]
Zhu, Fengxi [1 ]
Huang, Wen [1 ]
He, Huan [2 ,3 ]
Hui, Jiapeng [3 ]
Sun, Cheng [1 ]
Xian, Qiming [1 ]
Yang, Shaogui [2 ]
机构
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resource Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] Nanjing Normal Univ, Sch Environm, Nanjing 210023, Jiangsu, Peoples R China
[3] Wuyi Univ, Coll Ecol & Resource Engn, Fujian Prov Key Lab Ecoind Green Technol, Wuyishan 354300, Peoples R China
基金
中国国家自然科学基金;
关键词
Zeolite imidazolate framework-8; Nitro polycyclic aromatic hydrocarbons and polycyclic aromatic hydrocarbons; Solid phase microextraction; Sol-gel technology; Gas chromatography-mass spectrometry; SITU HYDROTHERMAL GROWTH; ROOM-TEMPERATURE SYNTHESIS; STAINLESS-STEEL WIRE; COATED FIBER; SOLVOTHERMAL SYNTHESIS; LIQUID-CHROMATOGRAPHY; EXTRACTION; SORBENT; NANOTUBES; TRENDS;
D O I
10.1016/j.chroma.2019.06.063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, three kinds of Zeolite imidazolate framework-8 (ZIF-8), synthesized by solvothermal, stirring and ball-milling method, were fabricated on the stainless steel wire via sol-gel technique. These fibers were used as solid phase microextraction (SPME) coating materials and applied for analyzing 16 polycyclic aromatic hydrocarbons (PAHs) and 11 nitro polycyclic aromatic hydrocarbons (NPAHs) in environmental water samples by gas chromatography-tandem mass spectrometry (GC-MS). The optimal pH, ionic strength, extraction time, extraction temperature, desorption temperature and desorption time were 6.0, without salt addition, 45 min, 35 degrees C, 260 degrees C and 5 min, respectively. The extraction mechanism of the ZIF-8 fiber might be the hydrophobicity, molecular penetration and pi-pi stacking interactions. Under the optimized conditions, the as-proposed fiber provides a wide linearity range from 10 to 20,000 ng L-1 and a low detection limit of 0.3-27.0 ng L-1 for PAHs and NPAHs analysis. The single fiber and fiber to fiber relative standard deviations were observed in the range of 3.0%-13.9% and 3.5%-12.3%, respectively. The method shows great potential in environmental analysis field. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 101
页数:10
相关论文
共 50 条
  • [31] Natural cotton fibers as adsorbent for solid-phase extraction of polycyclic aromatic hydrocarbons in water samples
    Wang, Jianping
    Liu, Shengquan
    Chen, Chunyan
    Zou, Ying
    Hu, Huiping
    Cai, Qingyun
    Yao, Shouzhuo
    ANALYST, 2014, 139 (14) : 3593 - 3599
  • [32] Solid phase microextraction of polycyclic aromatic hydrocarbons from water samples by a fiber coated with covalent organic framework modified carbon nitride
    Zang, Xiaohuan
    Pang, Yachao
    Li, Hongda
    Chang, Qingyun
    Zhang, Shuaihua
    Wang, Chun
    Wang, Zhi
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1628
  • [33] Zinc(II)-based metal-organic nanotubes coating for high sensitive solid phase microextraction of nitro-polycyclic aromatic hydrocarbons
    Wang, Xia
    Sheng, Wan-Ru
    Jiao, Xiao-Yun
    Zhao, Ru-Song
    Wang, Ming-Lin
    Lin, Jin-Ming
    TALANTA, 2018, 186 : 561 - 567
  • [34] Determination of nanomolar dissolved polycyclic aromatic hydrocarbons in different water and wastewater samples using a metal-organic framework-199@ graphene oxide fiber and headspace solid-phase microextraction
    Kardani, Fatemeh
    Mirzajani, Roya
    Ramezani, Zahra
    DESALINATION AND WATER TREATMENT, 2019, 144 : 99 - 115
  • [35] Magnetic metal-organic framework MIL-100(Fe) microspheres for the magnetic solid-phase extraction of trace polycyclic aromatic hydrocarbons from water samples
    Du, Fuyou
    Qin, Qun
    Deng, Jianchao
    Ruan, Guihua
    Yang, Xianqing
    Li, Laihao
    Li, Jianping
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (12) : 2356 - 2364
  • [36] A sol-gel based solid phase microextraction fiber for analysis of aromatic hydrocarbons
    Farhadi, Khalil
    Mamaghanian, Maliheh
    Maleki, Ramin
    JOURNAL OF HAZARDOUS MATERIALS, 2008, 152 (02) : 677 - 682
  • [37] Barium Sulfate Nanoparticles as a Coating for Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons in Aqueous Samples
    Feng, Jiaqing
    Sun, Min
    Wang, Xiuqin
    Tian, Yu
    Luo, Chuannan
    Feng, Juanjuan
    CHROMATOGRAPHIA, 2018, 81 (09) : 1287 - 1292
  • [38] Barium Sulfate Nanoparticles as a Coating for Solid-Phase Microextraction of Polycyclic Aromatic Hydrocarbons in Aqueous Samples
    Jiaqing Feng
    Min Sun
    Xiuqin Wang
    Yu Tian
    Chuannan Luo
    Juanjuan Feng
    Chromatographia, 2018, 81 : 1287 - 1292
  • [39] Quantitative determination of 16 polycyclic aromatic hydrocarbons in soil samples using solid-phase microextraction
    Wang, Yonghua
    Zhang, Juan
    Ding, Youchao
    Zhou, Jia
    Ni, Lixiao
    Sun, Cheng
    JOURNAL OF SEPARATION SCIENCE, 2009, 32 (22) : 3951 - 3957
  • [40] Porous carbon derived from aluminum-based metal organic framework as a fiber coating for the solid-phase microextraction of polycyclic aromatic hydrocarbons from water and soil
    Xi Zhang
    Xiao Huan Zang
    Jun Tao Wang
    Chun Wang
    Qiu Hua Wu
    Zhi Wang
    Microchimica Acta, 2015, 182 : 2353 - 2359