Stereotactic clamp accessories for Deep Brain Stimulation electrode placement

被引:0
|
作者
Smith, S [1 ]
Ramirez, MR [1 ]
Mendez, I [1 ]
机构
[1] IWK Grace Hlth Ctr, Halifax, NS, Canada
关键词
Deep Brain Stimulation; electrode; stereotactic surgery; instrumentation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A set of prototype clamping devices for maintaining electrode position during deep brain stimulation surgery are described. Typically, during deep brain surgery, a stereotactic frame is used to implant a semi-rigid electrode into the thalamus. A rigid cannula (hollow needle), surrounding the electrode, is used to guide the electrode during insertion. We have developed clamps designed to ensure the position of the implanted electrode is not inadvertently moved when the guide cannula is withdrawn.
引用
收藏
页码:18 / 19
页数:2
相关论文
共 50 条
  • [1] Accuracy of stereotactic electrode placement in deep brain stimulation
    Fiegele, T.
    Sohm, F.
    Bauer, R.
    Anton, J.
    Twerdy, K.
    Eisner, W.
    MOVEMENT DISORDERS, 2006, 21 : S667 - S668
  • [2] Accuracy of stereotactic electrode placement in deep brain stimulation by intraoperative computed tomography
    Fiegele, Thomas
    Feuchtner, Gudrun
    Sohm, Florian
    Bauer, Richard
    Anton, Juergen Volker
    Gotwald, Thaddaeus
    Twerdy, Klaus
    Eisner, Wilhelm
    PARKINSONISM & RELATED DISORDERS, 2008, 14 (08) : 595 - 599
  • [3] Deep brain stimulation using simultaneous stereotactic electrode placement. An alternative to conventional functional stereotaxy?
    Matzke, C.
    Hammer, N.
    Weise, D.
    Lindner, D.
    Fritzsch, D.
    Classen, J.
    Meixensberger, J.
    Winkler, D.
    NERVENARZT, 2014, 85 (12): : 1561 - +
  • [4] Comparison of the incidence of intracranial hemorrhage in two different planning techniques for stereotactic electrode placement in the deep brain stimulation
    Piacentino, M.
    Zambon, G.
    Pilleri, M.
    Bartolomei, L.
    JOURNAL OF NEUROSURGICAL SCIENCES, 2013, 57 (01) : 63 - 67
  • [5] Mathematical Equation for Precise Burr Hole Placement in Stereotactic Deep Brain Stimulation Lead Placement
    Urakov, Timur M.
    Jagid, Jonathan R.
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2017, 78 (06) : 607 - 609
  • [6] Placement accuracy of the second electrode in bilateral deep brain stimulation surgery
    Bunyaratavej, Krishnapundha
    Phokaewvarangkul, Onanong
    Wangsawatwong, Piyanat
    BRITISH JOURNAL OF NEUROSURGERY, 2021,
  • [7] Interventional MR Imaging for Deep-Brain Stimulation Electrode Placement
    Chansakul, Thanissara
    Chen, Paul N., Jr.
    Lee, Thomas C.
    Tierney, Travis
    RADIOLOGY, 2016, 281 (03) : 940 - 946
  • [8] Deep Brain Stimulation: Eye Movements Reveal Anomalous Effects of Electrode Placement and Stimulation
    Antoniades, Chrystalina A.
    Buttery, Philip
    FitzGerald, James J.
    Barker, Roger A.
    Carpenter, Roger H. S.
    Watts, Colin
    PLOS ONE, 2012, 7 (03):
  • [9] Correlation between MRI-based stereotactic thalamic deep brain stimulation electrode placement, macroelectrode stimulation and clinical response to tremor control
    Mobin, F
    De Salles, AAF
    Behnke, EJ
    Frysinger, R
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 1999, 72 (2-4) : 225 - 232
  • [10] Unusual reaction to deep brain stimulation electrode placement for Parkinson's disease
    Kraakevik, JA
    Brodsky, MA
    MOVEMENT DISORDERS, 2005, 20 : S162 - S162