Increased Signal Intensity in the Dentate Nucleus on Unenhanced T1-Weighted Images After Gadobenate Dimeglumine Administration

被引:159
|
作者
Weberling, Lukas D. [1 ,2 ]
Kieslich, Pascal J. [3 ]
Kickingereder, Philipp [1 ]
Wick, Wolfgang [4 ]
Bendszus, Martin [1 ]
Schlemmer, Heinz-Peter [2 ]
Radbruch, Alexander [1 ,2 ]
机构
[1] Heidelberg Univ, Med Ctr, Dept Neuroradiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Radiol, Heidelberg, Germany
[3] Univ Mannheim, Dept Psychol, D-68131 Mannheim, Germany
[4] Heidelberg Univ, Neurol Clin, Heidelberg, Germany
关键词
gadolinium retention; gadolinium deposition; linear gadolinium-based contrast agents; gadobenate dimeglumine; dentate nucleus; HEALTHY RATS DIFFERENCE; DEEP CEREBELLAR NUCLEI; CONTRAST AGENTS; MACROCYCLIC-AGENTS; GLOBUS-PALLIDUS; SAFETY; SPECTROSCOPY; HYPERSIGNAL; GADODIAMIDE; RETENTION;
D O I
10.1097/RLI.0000000000000206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aim of this study was to compare changes in signal intensity (SI) ratios of the dentate nucleus (DN) to pons and cerebrospinal fluid (CSF) on unenhanced T1-weighted magnetic resonance imaging (MRI) scans between the first and last MRI using the linear gadolinium-based contrast agent gadobenate dimeglumine. Materials and Methods The study was approved by the ethical committee of the University of Heidelberg (S-324/2014), and written informed consent was waived due to the retrospective character of the study. Fifty patients who underwent at least 5 consecutive MRI examinations (plus an additional last MRI for reference) with the exclusive use of gadobenate dimeglumine were analyzed retrospectively. The difference of DN-to-pons and DN-to-CSF mean SI ratios was calculated on unenhanced T1-weighted images between the first and last examination. Results were compared with previously published data on gadopentetate dimeglumine and gadoterate meglumine. Results Signal intensity ratio differences for DN-to-pons and DN-to-CSF were significantly greater than 0 (pons: 0.0399 0.0307, P < 0.001; CSF: 0.1439 +/- 0.1524, P < 0.001). No control variable consistently predicted the SI ratio difference for the DN-to-pons and the DN-to-CSF ratio. Compared with previously published data, the difference in SI increase between gadopentetate dimeglumine and gadobenate dimeglumine was not significant for the DN-to-pons ratio (P = 0.906). In contrast, the DN-to-CSF ratio difference was significantly lower (P < 0.001) for gadobenate dimeglumine. Dentate nucleus-to-pons (P < 0.001) and DN-to-CSF (P = 0.017) ratio differences were both significantly higher for gadobenate dimeglumine than for gadoterate meglumine. Conclusions The present study found an increase in SI in the DN after serial injections of gadobenate dimeglumine. Further studies are needed to clarify the potential of different linear gadolinium-based contrast agents to cause SI increase in the DN.
引用
收藏
页码:743 / 748
页数:6
相关论文
共 50 条
  • [21] High-Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted Images Evaluation of the Macrocyclic Gadolinium-Based Contrast Agent Gadobutrol
    Radbruch, Alexander
    Weberling, Lukas D.
    Kieslich, Pascal J.
    Hepp, Johanna
    Kickingereder, Philipp
    Wick, Wolfgang
    Schlemmer, Heinz-Peter
    Bendszus, Martin
    INVESTIGATIVE RADIOLOGY, 2015, 50 (12) : 805 - 810
  • [22] Dentate Nucleus Signal Intensity Increases Following Repeated Gadobenate Dimeglumine Administrations: A Retrospective Analysis
    Nguyen, Nghi C.
    Molnar, Theodore T.
    Cummin, Lucas G.
    Kanal, Emanuel
    RADIOLOGY, 2020, 296 (01) : 122 - 130
  • [23] EVALUATION OF HIGH SIGNAL INTENSITY IN GLOBUS PALLIDUS AND DENTATE NUCLEUS ON UNENHANCED T1-WEIGHTED IMAGES AFTER ADMINISTRATION OF DOTAREM VS. GADAVIST IN BRAIN TUMOR PATIENTS WHO UNDERGO MULTIPLE MRI EVALUATIONS
    Rozenblatt, S.
    Luckman, J.
    Yust-Katz, S.
    Siegal, T.
    NEURO-ONCOLOGY, 2018, 20 : 255 - 255
  • [24] Progressive increase of T1 signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted MR images in the pediatric brain exposed to multiple doses of gadolinium contrast
    Roberts, Donna R.
    Holden, Kenton R.
    BRAIN & DEVELOPMENT, 2016, 38 (03): : 331 - 336
  • [25] Multiple Sclerosis: Hyperintense Dentate Nucleus on Unenhanced T1-weighted MR Images Is Associated with the Secondary Progressive Subtype
    Roccatagliata, Luca
    Vuolo, Luisa
    Bonzano, Laura
    Pichiecchio, Anna
    Mancardi, Giovanni Luigi
    RADIOLOGY, 2009, 251 (02) : 503 - 510
  • [26] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-weighted MR Images: Relationship with Increasing Cumulative Dose of a Gadolinium-based Contrast Material
    Kanda, Tomonori
    Ishii, Kazunari
    Kawaguchi, Hiroki
    Kitajima, Kazuhiro
    Takenaka, Daisuke
    RADIOLOGY, 2014, 270 (03) : 834 - 841
  • [27] High Signal Intensity in the Dentate Nucleus and Globus Pallidus on Unenhanced T1-Weighted MR Images: Comparison between Gadobutrol and Linear Gadolinium-Based Contrast Agents
    Moser, F. G.
    Watterson, C. T.
    Weiss, S.
    Austin, M.
    Mirocha, J.
    Prasad, R.
    Wang, J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2018, 39 (03) : 421 - 426
  • [28] Repeated intravenous administration of gadobutrol does not lead to increased signal intensity on unenhanced T1-weighted images—a voxel-based whole brain analysis
    Soenke Langner
    Marie-Luise Kromrey
    Jens-Peter Kuehn
    Matthias Grothe
    Martin Domin
    European Radiology, 2017, 27 : 3687 - 3693
  • [29] CHANGES IN SIGNAL INTENSITY RATIOS OF GLOBUS PALLIDUS AND DENTATE NUCLEUS ON UNENHANCED T1-WEIGHTED IMAGES AFTER MULTIPLE ADMINISTRATIONS OF MACROCYCLIC GADOLINIUM-BASED CONTRAST AGENTS IN BRAIN TUMOR PATIENTS
    Rozenblatt, Shira
    Luckman, Judith
    Yust-Katz, Shlomit
    Siegal, Tali
    NEURO-ONCOLOGY, 2018, 20 : 191 - 191
  • [30] Repeated administrations of macrocyclic gadolinium based contrast agents in multiple sclerosis patients do not cause increased signal intensity in dentate nucleus and globus pallidus on T1-weighted unenhanced magnetic resonance images
    Sartori, Arianna
    Gennari, Antonio Giulio
    Zorzenon, Irene
    Bratina, Alessio
    Ukmar, Maja
    Bosco, Antonio
    Cova, Maria Assunta
    Manganotti, Paolo
    NEUROLOGY, 2017, 88