Measuring quaternary ammonium cleaning agents with ion selective electrodes

被引:18
|
作者
Plesha, Michael A.
Van Wie, Bernard J.
Mullin, James M.
Kidwell, David A.
机构
[1] Washington State Univ, Dept Chem Engn, Pullman, WA 99164 USA
[2] USN, Res Lab, Washington, DC 20375 USA
关键词
ion selective electrode; surfactant; quaternary ammonium ion; selectivity; polymeric reference electrode;
D O I
10.1016/j.aca.2006.04.024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Data for coated-wire, ion selective electrodes (ISEs) are presented for cationic surfactant ions found in common cleaners including benzyldimethyltetradecylammonium, benzyldimethyldodecylanunonium, and benzyldimethylhexadecylammonium. The ion exchangers dinonylnaphthalene sulfonic acid, tetraphenyborate, and tetrakis(4-chlorophenyl)borate are examined, showing dinonylnaphthalene sulfonic acid to be the favored species. The ISEs exhibit approximately Nernstian behavior down to the 10(-6) M limit of detection with lifetimes in excess of 50 days when used continuously, and a shelf life of over 100 days. Reaching the upper detection limit at the critical micelle concentration requires use of polymeric-membrane reference electrodes including a new membrane cocktail, which allow response measurements of an order of magnitude higher than the traditional fritted-glass reference electrode. The surfactant ISEs show excellent selectivity over the common metal ions Na+, K+, Mg2+, Ca2+, and Cu2+ with selectivity coefficients less than 10(-5.3). The ISEs are also selective over the lower molecular weight quaternary ammonium ions tetradecyltrimethylammonium, dodecyltrimethylammonium, benzyldimethyl(2-hydroxyethyl)ammonium, and tetrabutylammonium with selectivity coefficients ranging from 10-(1.7) to 10(-5.5). Use of a single electrode to determine accurately the total cationic surfactant concentration in common cleaning solutions is accomplished with information about concentration dependent interferences and a modified Nikolsky-Eisenman model. Finally, quaternary ammonium surfactants have a deleterious effect on the measurements of pH and common ions like K+, Mg2+ and Ca2+ with polymeric ISEs. This makes it critical to include surfactant electrodes in a detector array when cleaning agents are present. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 50 条
  • [41] POLYMERIC QUATERNARY AMMONIUM BOROHYDRIDE REDUCING AGENTS
    COOK, MM
    WAGNER, SE
    DEMKO, PR
    CLEMENTS, JG
    MIKULSKI, RA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1978, 176 (SEP): : 133 - 133
  • [42] HOT, ACIDIC QUATERNARY AMMONIUM CLEANING SYSTEM FOR MILKING MACHINES
    HEYES, IH
    DUNSMORE, DG
    NEW ZEALAND JOURNAL OF DAIRY SCIENCE AND TECHNOLOGY, 1978, 13 (01): : 54 - 55
  • [43] INVESTIGATION OF ION-SELECTIVE ELECTRODES BASED ON QUATERNARY PHOSPHONIUM SALTS .3. AN ION-SELECTIVE ELECTRODE FOR HEXAFLUOROPHOSPHATE
    KOPYTIN, AV
    GABORKLATSMANYI, P
    IZVEKOV, VP
    PUNGOR, E
    ILYIN, EG
    ANALYTICA CHIMICA ACTA, 1984, 162 (AUG) : 133 - 140
  • [44] [Zn(NCS)4]2--Selective electrodes based on higher quaternary ammonium salts (QAS)
    Rakhman'ko, E. M.
    Matveichuk, Yu. V.
    Yasinetskii, V. V.
    Stanishevskii, L. S.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2013, 68 (04) : 328 - 334
  • [45] ROLE OF TRIFLUOROACETOPHENONE SOLVENTS AND QUATERNARY AMMONIUM-SALTS IN CARBONATE-SELECTIVE LIQUID MEMBRANE ELECTRODES
    MEYERHOFF, ME
    PRETSCH, E
    WELTI, DH
    SIMON, W
    ANALYTICAL CHEMISTRY, 1987, 59 (01) : 144 - 150
  • [46] ION SELECTIVE ELECTRODES
    SIMPSON, RJ
    EFFLUENT & WATER TREATMENT JOURNAL, 1971, 11 (02): : 96 - &
  • [47] The fabrication of all solid-state ammonium ion selective electrodes used in aquaculture
    Wu, Keqi
    Fu, Linfeng
    Guo, Xishan
    Zhu, Songming
    2017 IEEE SENSORS, 2017, : 1290 - 1292
  • [48] Ion-selective electrodes for determination of organic ammonium ions: Ways for selectivity control
    Egorov, Vladimir V.
    Bolotin, Alexander A.
    TALANTA, 2006, 70 (05) : 1107 - 1116
  • [49] Reduction of ammonium ion on Pt electrodes
    Berkh, O.
    Shacham-Diamand, Y.
    Gileadi, E.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2008, 155 (10) : F223 - F229
  • [50] Measuring the solubilities of ionic liquids in water using ion-selective electrodes
    Natalia V. Shvedene
    Svetlana V. Borovskaya
    Victor V. Sviridov
    Erika R. Ismailova
    Igor V. Pletnev