A study of hydrogel thermal-dynamics using Fourier transform infrared spectrometer

被引:21
|
作者
Ding, Xiaoling [1 ]
Fries, David [1 ]
Jun, Bokkyoo [1 ]
机构
[1] Univ S Florida, Coll Marine Sci, Ctr Ocean Technol, St Petersburg, FL 33701 USA
关键词
hydrogel; FTIR; thermal-dynamics;
D O I
10.1016/j.polymer.2006.04.022
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A rapid and reliable method was presented for studying hydrogel dynamics/kinetics. Two temperature-sensitive hydrogels, poly-N-isopropylacrylamide (poly(NIPAAm)) and the copolymer of N,N-diethylacrylamide and sodium methacrylate (molar ratio=97:3, poly(NDEAAm-co-MAA)) were synthesized. The thermal-behaviors of the gels were studied through the absorbance intensities of both swollen water and gel frame components, and the peak positions of amide band along heating/cooling pathways under dynamic Fourier transform infrared (FTIR) probing. The results showed that the lower critical solution temperature (LCST) of poly(NIPAAm) is about 33-35 degrees C, which is consistent with reported value of similar to 34 degrees C. Compared to poly(NIPAAm), poly(NDEAAm-co-MAA) has relatively continuous volume phase transition, starting at similar to 35 degrees C and a better thermal-reversibility with similar swelling and deswelling profiles over a larger temperature range (10-80 degrees C for poly(NDEAAm-co-MAA) vs. 10-33 degrees C for poly(NIPAAm)). The H-bonding water along phase transition was also studied, showing a less reversibility of poly(NIPAAm) compared to poly(NDEAAm-co-MAA). In addition, FTIR spectrometer was also used to study the volume changes of poly(NDEAAm-co-MAA) under variations in environmental salinity. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4718 / 4725
页数:8
相关论文
共 50 条
  • [11] FOURIER-TRANSFORM INFRARED STUDY OF REPTATION DYNAMICS
    LEE, A
    WOOL, RP
    AIP CONFERENCE PROCEEDINGS, 1985, (137) : 255 - 260
  • [12] An ultrahigh vacuum surface analysis instrument incorporating a Fourier transform mass spectrometer and a Fourier transform infrared spectrometer
    Abdelrehim, IM
    Thornburg, NA
    Land, DP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (12): : 4572 - 4582
  • [13] Fourier transform spectrometer for thermal-infrared emissivity measurements near room temperatures
    Ishii, J
    Ono, A
    OPTICAL DIAGNOSTIC METHODS FOR INORGANIC MATERIALS II, 2000, 4103 : 126 - 132
  • [14] Analysis of the physical simulation on Fourier Transform Infrared Spectrometer
    Yue Peng-yuan
    Wan Yu-xi
    Zhao Zhen
    AOPC 2017: OPTICAL SPECTROSCOPY AND IMAGING, 2017, 10461
  • [15] Performance test of Fourier transform infrared imaging spectrometer
    Li, Jian-Hua
    Xue, Feng
    Xue, Lian
    Li, Zhi-Feng
    Liu, Jia-Qi
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 : 190 - 196
  • [16] The application of Fourier transform infrared spectrometer to the smoke determination
    Wang, NY
    Wang, ZP
    Dong, HB
    Zhang, GB
    Liu, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (04) : 443 - 445
  • [17] Static Fourier Transform Spectrometer for the medium Infrared Range
    Schardt, Michael
    Rauscher, Markus S.
    Murr, Patrik J.
    Tremmel, Anton J.
    Koch, Alexander W.
    XXX. MESSTECHNISCHES SYMPOSIUM, 2016, : 95 - 102
  • [18] The DREV infrared imaging Fourier transform spectrometer system
    Smithson, T
    Roney, P
    Robitaille, N
    Perreault, A
    Boley, G
    Cardinal, M
    Villemaire, A
    Fortin, S
    Giroux, J
    TWENTY-SECOND INTERNATIONAL PYROTECHNICS SEMINAR, 1996, : 735 - 772
  • [19] Measurement of Fourier transform infrared spectrometer instrument lineshape
    Davies, N
    Bell, W
    Vance, A
    Hilton, M
    SPECTROSCOPIE ATMOSPHERIC ENVIRONMENTAL MONITORING TECHNIQUES, 1998, 3493 : 79 - 87
  • [20] Infrared Fourier transform spectrometer based on MOEMS technology
    Lü, Jin-Guang
    Liang, Jing-Qiu
    Liang, Zhong-Zhu
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2011, 19 (SUPPL.2): : 85 - 91