Effects of forced-to-exhaust ratio of air volume on dust control of wall-attached swirling ventilation for mechanized excavation face

被引:90
|
作者
Wang, Pengfei [1 ,3 ]
Li, Yongjun [2 ]
Liu, Ronghua [2 ,3 ]
Shi, Yijie [2 ]
机构
[1] Hunan Univ Sci & Technol, Work Safety Key Lab Prevent & Control Gas & Roof, Xiangtan 411201, Peoples R China
[2] Hunan Univ Sci & Technol, Sch Resource Environm & Safety Engn, Xiangtan 411201, Peoples R China
[3] Hunan Univ Sci & Technol, Hunan Prov Key Lab Safe Min Tech Coal Mines, Xiangtan 411201, Peoples R China
基金
中国国家自然科学基金;
关键词
Mechanized excavation face; Wall-attached swirling ventilation; Forced-to-exhaust air volume ratio; Dust; Dust separation efficiency; NUMERICAL-SIMULATION; CURTAIN GENERATOR; RESPIRABLE DUST; MINING FACE; CFD; DIFFUSION; ATOMIZATION; SUPPRESSION; PERFORMANCE; PARTICLES;
D O I
10.1016/j.tust.2019.04.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Wall-attached swirling ventilation is a new type of ventilation for the mechanized excavation face. The dust control effect of the wall-attached swirling ventilation is affected by the forced-to-exhaust air volume ratio. In order to investigate the influence of the air volume ratio on the dust control effect of mechanized excavation face, art experimental model of the wall-attachment swirling ventilation for mechanized excavation face was developed as a reduced scale representation of the D04 mechanized excavation face in Dong Huai Coal Mine of Guangxi Baise Baikuang Group Co., Ltd. Based on this model, the airflow field and dust control of mechanized excavation face at different forced-to-exhaust ratios was analyzed using the study equipment including particle image velocimetry (PIV) system, FCC-25 explosion-proof dust sampler, LS 13320 laser diffraction particle size analyzer, and etc. The analysis results showed that the air velocity at the front end of air supply tube in the wall-attached swirling ventilation was small, the disturbance to the dust production at the heading end by the air flow was weak, and the dust dispersion ability was weak at the front end. In the wall-attached swirling ventilation, both radial air curtain and axial air curtain were generated and pointing to heading end. The cooperation effect of both air curtains controlled dust in the heading area. Thus the operating area for the driver was kept clean and fresh when wall-attached swirling ventilation was running, which ensured a healthy working environment for the roadheader driver. The dust control effect of wall swirling ventilation depended on not only axial air curtain but also radial air curtain. If the forced-to-exhaust ratio was increased, on one hand, the disturbance on the flow field was larger and the intensity of the axial air curtain in the heading end area was weaker; on the other hand, the intensity of the radial air curtain and the dust separation ability were enhanced. When the forced-to-exhaust ratio was 0.8, the wall-attached swirling showed the best dust control effect, the concentration of both the full dust and the respiratory dust around the driver was the lowest, and the separation efficiencies for the full dust and respiratory dust were the highest, which were 93.64% and 98.18%, respectively.
引用
收藏
页码:194 / 207
页数:14
相关论文
共 27 条
  • [21] The effects of the installation position of a multi-radial swirling air-curtain generator on dust diffusion and pollution rules in a fully-mechanized excavation face: A case study
    Liu, Qiang
    Nie, Wen
    Hua, Yun
    Peng, Huitian
    Liu, Zhiqiang
    POWDER TECHNOLOGY, 2018, 329 : 371 - 385
  • [22] Effects of forced-air volume and suction region on the migration and dust suppression of air curtain during fully mechanized tunneling process
    Wang, Hao
    Sa, Zhanyou
    Cheng, Weimin
    Zhang, Ran
    Yang, Shuai
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2021, 145 : 222 - 235
  • [23] Effects of forced-air volume and suction region on the migration and dust suppression of air curtain during fully mechanized tunneling process
    Wang, Hao
    Sa, Zhanyou
    Cheng, Weimin
    Zhang, Ran
    Yang, Shuai
    Process Safety and Environmental Protection, 2021, 145 : 222 - 235
  • [24] Effects of radial air flow quantity and location of an air curtain generator on dust pollution control at fully mechanized working face
    Wang, Hao
    Cheng, Weimin
    Sun, Biao
    Ma, Youying
    ADVANCED POWDER TECHNOLOGY, 2017, 28 (07) : 1780 - 1791
  • [25] Long-duct forced and short-duct exhaust ventilation system in tunnels: Formation and dust control analysis of pressure ventilation air curtain
    Liu, Qiang
    Nie, Wen
    Hua, Yun
    Peng, Huitian
    Ma, He
    Yin, Shuai
    Guo, Lidian
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2019, 132 : 367 - 377
  • [26] The impacts of the axial-to-radial airflow quantity ratio and suction distance on air curtain dust control in a fully mechanized coal face
    Hao Wang
    Weimin Cheng
    Biao Sun
    Haiming Yu
    Hu Jin
    Environmental Science and Pollution Research, 2018, 25 : 7808 - 7822
  • [27] The impacts of the axial-to-radial airflow quantity ratio and suction distance on air curtain dust control in a fully mechanized coal face
    Wang, Hao
    Cheng, Weimin
    Sun, Biao
    Yu, Haiming
    Jin, Hu
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (08) : 7808 - 7822