The influence of image reconstruction algorithms on linear thorax EIT image analysis of ventilation

被引:12
|
作者
Zhao, Zhanqi [1 ,2 ]
Frerichs, Inez [3 ]
Pulletz, Sven [4 ]
Mueller-Lisse, Ullrich [2 ]
Moeller, Knut [1 ]
机构
[1] Furtwangen Univ, Inst Tech Med, D-78054 Villingen Schwenningen, Germany
[2] Univ Munich, Dept Radiol, D-80336 Munich, Germany
[3] Univ Med Ctr Schleswig Holstein, Dept Anesthesiol & Intens Care Med, D-24105 Kiel, Germany
[4] Med Ctr Osnabruck, Dept Anaesthesiol & Intens Care Med, D-49076 Osnabruck, Germany
关键词
electrical impedance tomography; image analysis; mechanical ventilation; ventilation distribution; computed tomography; ELECTRICAL-IMPEDANCE TOMOGRAPHY; REGIONAL VENTILATION; LUNG; RECRUITMENT; PRESSURE; MANEUVER;
D O I
10.1088/0967-3334/35/6/1083
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Analysis methods of electrical impedance tomography (EIT) images based on different reconstruction algorithms were examined. EIT measurements were performed on eight mechanically ventilated patients with acute respiratory distress syndrome. A maneuver with step increase of airway pressure was performed. EIT raw data were reconstructed offline with (1) filtered back-projection (BP); (2) the Drager algorithm based on linearized Newton-Raphson (DR); (3) the GREIT (Graz consensus reconstruction algorithm for EIT) reconstruction algorithm with a circular forward model (GRC) and (4) GREIT with individual thorax geometry (GR(T)). Individual thorax contours were automatically determined from the routine computed tomography images. Five indices were calculated on the resulting EIT images respectively: (a) the ratio between tidal and deep inflation impedance changes; (b) tidal impedance changes in the right and left lungs; (c) center of gravity; (d) the global inhomogeneity index and (e) ventilation delay at mid-dorsal regions. No significant differences were found in all examined indices among the four reconstruction algorithms (p > 0.2, Kruskal-Wallis test). The examined algorithms used for EIT image reconstruction do not influence the selected indices derived from the EIT image analysis. Indices that validated for images with one reconstruction algorithm are also valid for other reconstruction algorithms.
引用
收藏
页码:1083 / 1093
页数:11
相关论文
共 50 条
  • [31] Robust linearized image reconstruction for multifrequency EIT of the breast
    Boverman, Gregory
    Kao, Tzu-Jen
    Kulkarni, Rujuta
    Kim, Bong Seok
    Isaacson, David
    Saulnier, Gary J.
    Newell, Jonathan C.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (10) : 1439 - 1448
  • [32] The number of electrodes and basis functions in EIT image reconstruction
    Tang, MX
    Wang, W
    Wheeler, J
    McCormick, M
    Dong, XZ
    PHYSIOLOGICAL MEASUREMENT, 2002, 23 (01) : 129 - 140
  • [34] Analysis on the influence of tissues/organs' movements in EIT images of lung ventilation using finite difference thorax models
    Zhang, J
    Patterson, RP
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 1557 - 1560
  • [35] Validation of three deformable image registration algorithms for the thorax
    Latifi, Kujtim
    Zhang, Geoffrey
    Stawicki, Marnix
    van Elmpt, Wouter
    Dekker, Andre
    Forster, Kenneth
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 19 - 30
  • [36] Performance analysis of the filtered backprojection image reconstruction algorithms
    Pipatsrisawat, T
    Gacic, A
    Franchetti, F
    Püschel, M
    Moura, JMF
    2005 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1-5: SPEECH PROCESSING, 2005, : 153 - 156
  • [37] Analysis on the image reconstruction accuracy of three statistical algorithms
    Pan, JX
    Han, Y
    Wang, LM
    Gui, ZG
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1260 - 1262
  • [38] Linear algebraic algorithms for high speed and stable reconstruction of plasma image
    Terasaki, N
    Hosoda, Y
    Teranishi, M
    Iwama, N
    FUSION ENGINEERING AND DESIGN, 1997, 34-35 : 801 - 804
  • [39] Simulation research on evaluation of EIT image reconstructed by different algorithms
    Deng, Juan
    Sha, Hong
    Wang, Yan
    Zhao, Shu
    Ren, Chaoshi
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [40] Assessing the Effect of Error in Modelling on Accuracy of EIT Image Reconstruction
    Chin, Renee K. Y.
    Aziz, Debrianty
    Teo, Kenneth T. K.
    2014 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA), 2014,