Effect of operating parameters on the DMFC performance

被引:34
|
作者
Jung, Guo-Bin
Su, Ay
Tu, Cheng-Hsin
Weng, Fang-Bor
机构
[1] Yuan Ze Univ, Fuel Cell Ctr, Taoyuan 320, Taiwan
[2] Yuan Ze Univ, Dept Mech Engn, Taoyuan 320, Taiwan
来源
关键词
direct methanol fuel cell (DMFC); membrane electrode assembly (MEA); open circuit voltage (OCV); crossover; Nafion;
D O I
10.1115/1.1840887
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Methanol crossover largely affects the efficiency of power generation in the direct methanol fuel cell. As the methanol crosses over through the membrane, the methanol oxidizes at the cathode, resulting in low fuel utilization and in a serious overpotential loss. In this study, the commercial membrane electrode assemblies (MEAs) are investigated with different operating conditions such as membrane thickness, cell temperature, and methanol solution concentration. The effects of these parameters on methanol crossover and power density are studied. With the same membrane, increasing the cell temperature promotes the-cell performance as expected, and the lower methanol concentration causes the concentration polarization effects, thus resulting in lower cell performance. Although higher methanol solution concentration can overcome the concentration polarization, a serious methanol crossover decreases the cell performance at high cell temperature. In this study, the open circuit voltage (OCV) is inversely proportional to methanol solution concentration, and is proportional to membrane thickness and cell temperature. Although increasing membrane thickness lowers the degree of methanol crossover on the other hand, the ohmic resistance increases simultaneously. Therefore, the cell performance using Nafion 117 as membrane is lower than that of Nafion 112. In addition, the performance of the MEA made in our laboratory is higher than the commercial product, indicating the capability of manufacturing MEA is acceptable.
引用
收藏
页码:81 / 85
页数:5
相关论文
共 50 条
  • [31] Experimental Study on the Effect of Operating Parameters on the Performance of TVSA Carbon Capture Unit
    Bai, Yadi
    Wang, Shengyan
    Deng, Shuai
    Li, ShuangJun
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2023, 44 (11): : 3022 - 3031
  • [32] Effect of design and operating parameters of performance of inter-cultivation sweep vertisols
    Yadav, S. N.
    Pandey, M. M.
    Saraswat, D. C.
    AMA-AGRICULTURAL MECHANIZATION IN ASIA AFRICA AND LATIN AMERICA, 2007, 38 (03): : 38 - 44
  • [33] Computational and Experimental Study of the Effect of Operating Parameters on Classification Performance of Compound Hydrocyclone
    Jiang, Jin
    Ying, Rui
    Feng, Jingan
    Wang, Weibing
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2018, 2018
  • [34] Effect of operating parameters on the drying performance of multicylinder paper machine dryer section
    Kong, Lingbo
    Tao, Zhengyi
    Liu, Huanbin
    Zhang, Dinghua
    DRYING TECHNOLOGY, 2016, 34 (13) : 1641 - 1650
  • [36] Effect of operating parameters on application based performance analysis of PDC: A recent review
    Debnath, Pinku
    Pandey, K. M.
    MATERIALS TODAY-PROCEEDINGS, 2021, 45 : 6702 - 6707
  • [37] Effect of operating parameters and pesticide flow characteristics on performance of air assisted spraying
    Dhalin, D.
    Kathirvel, K.
    Job, T. V.
    Manian, R.
    AMA-AGRICULTURAL MECHANIZATION IN ASIA AFRICA AND LATIN AMERICA, 2008, 39 (01): : 39 - 45
  • [38] Dissecting the performance of a jet nebulizer: The effect of changing design parameters and operating conditions
    Soni, Harshit
    Beaudry, Ben
    O'Neil, Jennifer
    Villasmil-Urdaneta, Larry
    AEROSOL SCIENCE AND TECHNOLOGY, 2024, 58 (07) : 727 - 738
  • [39] Effect of operating and design parameters on the performance of a microbial fuel cell with Lactobacillus pentosus
    Vilas Boas, J.
    Oliveira, V. B.
    Marcon, L. R. C.
    Pinto, D. P.
    Simoes, M.
    Pinto, A. M. F. R.
    BIOCHEMICAL ENGINEERING JOURNAL, 2015, 104 : 34 - 40
  • [40] Effect of Operating Parameters on Performance of Ultrafiltration (UF) to Fractionate Catfish Protein Hydrolysate
    Novin, D.
    Yunos, K. F. M. D.