Voltammetric determination of ethinylestradiol using screen-printed electrode modified with functionalized graphene, graphene quantum dots and magnetic nanoparticles coated with molecularly imprinted polymers

被引:46
|
作者
Santos, Anderson M. [1 ]
Wong, Ademar [1 ,2 ,3 ]
Prado, Thiago M. [1 ]
Fava, Elson L. [1 ]
Fatibello-Filho, Orlando [1 ]
Sotomayor, Maria D. P. T. [2 ,3 ]
Moraes, Fernando C. [1 ]
机构
[1] Univ Fed Sao Carlos, Dept Chem, Rod Washington Luis Km 235,POB 676, BR-13560970 Sao Carlos, SP, Brazil
[2] State Univ Sao Paulo, Inst Chem, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil
[3] INCT DATREM, BR-14801970 Araraquara, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
MIP; Graphene; Quantum dots; Screen-printed electrode; Ethinylestradiol; WALLED CARBON NANOTUBES; ELECTROCHEMICAL SENSOR; ENDOCRINE DISRUPTORS; SENSITIVE DETECTION; IN-VIVO; OXIDE; FILMS; ETHYNYLESTRADIOL; PERFORMANCE; EXTRACTION;
D O I
10.1016/j.talanta.2020.121804
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The present work reports the development of a sensitive and selective method for ethinylestradiol detection using screen-printed electrode (SPE) modified with functionalized graphene (FG), graphene quantum dots (GQDs) and magnetic nanoparticles coated with molecularly imprinted polymers (mag@MIP). The performance of the mag@MIP sensor was compared with that of a non-molecularly imprinted sensor (mag@NIP). Chemical and physical characterizations of the mag@NIP and mag@MIP sensors were performed using scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and Brunauer-Emmett-Teller (BET) techniques. The electrochemical behavior of the electrodes investigated, which included (mag@MIP)-GQDs-FG-NF/SPE, (mag@NIP)-GQDs-FG-NF/SPE, GQDs-FG-NF/SPE and FG-NF/SPE, was evaluated by cyclic voltammetry. The results obtained show a significant increase in peak current magnitude for (mag@MIP)-GQDs-FG-NF/SPE. Using square wave voltammetry experiments, the efficiency of the (mag@MIP)-GQDs-FG-NF/SPE sensor was also tested under optimized conditions. The linear response range obtained for ethinylestradiol concentration was 10 nmol L-1 to 2.5 mu mol L-1, with limit of detection of 2.6 nmol L-1. The analytical signal of the (mag@MIP)-GQDs-FG-NF/SPE sensor suffered no interference from different compounds and the sensor exhibited good repeatability. The proposed sensor was successfully applied for ethynilestradiol detection in river water, serum and urine samples, where recovery rates between 96 to 105% and 97-104% were obtained for environmental and biological samples, respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Molecularly imprinted polypyrrole-modified screen-printed electrode: Toward a sensor for furfural derivatives determination
    Merli, Daniele
    Cutaia, Alessandra
    Prosperi, Sofia
    Zanoni, Camilla
    Alberti, Giancarla
    SENSORS AND ACTUATORS REPORTS, 2025, 9
  • [32] Voltammetric determination of urinary 1-hydroxypyrene using molecularly imprinted polymer-modified screen-printed carbon electrodes
    Kirsch, N
    Honeychurch, KC
    Hart, JP
    Whitcombe, MJ
    ELECTROANALYSIS, 2005, 17 (07) : 571 - 578
  • [33] Electrochemical determination of 5-heneicosylresorcinol using a disposable molecularly imprinted polymer-modified screen-printed electrode
    Wang, Mengyao
    Gong, Weiwei
    Yu, Zhenjia
    Wang, Hailin
    Sun, Ruiqing
    Wen, Yangyang
    Li, Hongyan
    Wang, Jing
    FOOD CONTROL, 2025, 171
  • [34] Palladium nanoparticles functionalized graphene quantum dots with molecularly imprinted polymer for electrochemical analysis of citrinin
    Akyildirim, Onur
    Kardas, Faruk
    Beytur, Murat
    Yuksek, Haydar
    Atar, Necip
    Yola, Mehmet Lutfi
    JOURNAL OF MOLECULAR LIQUIDS, 2017, 243 : 677 - 681
  • [35] Nitrogen-doped graphene quantum dots coated with molecularly imprinted polymers as a fluorescent sensor for selective determination of warfarin
    Li, Peipei
    Du, Yingxiang
    Ma, Mingxuan
    Zhang, Jian
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (16) : 7537 - 7544
  • [36] Simultaneous voltammetric determination of acetaminophen and isoniazid using MXene modified screen-printed electrode
    Zhang, Yu
    Jiang, Xiantao
    Zhang, Junjie
    Zhang, Han
    Li, Yingchun
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 315 - 321
  • [37] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Nahid Shoaie
    Mehdi Forouzandeh
    Kobra Omidfar
    Microchimica Acta, 2018, 185
  • [38] Voltammetric determination of the Escherichia coli DNA using a screen-printed carbon electrode modified with polyaniline and gold nanoparticles
    Shoaie, Nahid
    Forouzandeh, Mehdi
    Omidfar, Kobra
    MICROCHIMICA ACTA, 2018, 185 (04)
  • [39] Graphene Quantum Dots Modified Graphite Screen Printed Electrode for the Electrochemical Detection of Acetylcholine
    Iran Zahra Dourandish
    Hadi Sheikhshoaie
    Russian Journal of Electrochemistry, 2022, 58 : 716 - 724
  • [40] Graphene Quantum Dots Modified Graphite Screen Printed Electrode for the Electrochemical Detection of Acetylcholine
    Dourandish, Zahra
    Sheikhshoaie, Iran
    Beitollahi, Hadi
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2022, 58 (08) : 716 - 724