Assessment of the indoor air quality in copy centres at Aveiro, Portugal

被引:26
|
作者
Vicente, Estela D. [1 ]
Ribeiro, Joao P. [1 ]
Custodio, Danilo [1 ]
Alves, Celia A. [1 ]
机构
[1] Univ Aveiro, Dept Environm & Planning, Ctr Environm & Marine Studies, P-3810193 Aveiro, Portugal
来源
AIR QUALITY ATMOSPHERE AND HEALTH | 2017年 / 10卷 / 02期
关键词
Indoor air quality; Copy centre; Particulate matter; Ozone; VOLATILE ORGANIC-COMPOUNDS; VENTILATION RATES; OFFICE EQUIPMENT; OZONE; HEALTH; EXPOSURE; POLLUTANTS; PERFORMANCE; BUILDINGS; CONTAMINANTS;
D O I
10.1007/s11869-016-0401-8
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study presents continuous measurements of size-segregated particulate matter, total volatile organic compounds, ozone, formaldehyde, comfort parameters (temperature and relative humidity), CO and CO2 at two copy centres (A and B) in Aveiro, Portugal. PM10 samples collected with low-volume samplers were used to determine the carbonaceous content (organic and elemental carbon) by a thermo-optical technique. Mean PM10 levels of 55.8 +/- 7.50 mu g m(-3) and 51.3 +/- 9.35 mu g m(-3) were obtained in copy centres A and B, respectively. The 24-h indoor PM10 concentration at both copy centres exceeded the protection limit established by the Portuguese legislation. Around 60 % of the PM10 were composed of particles with sizes below 2.5 mu m. On average, organic carbon accounted for 27.6 % (copy centre A) and 18.6 % (copy centre B) of the PM10 mass indoors, whereas a lower mass fraction of 11.5 % was found for both outdoor spaces. The much higher indoor levels of organic carbon suggest significant contribution by indoor sources. The ozone level increased in both copy centres when the photocopiers started to work. Mean ozone levels (0.055 +/- 0.005 and 0.048 +/- 0.006 ppm in copy centres A and B, respectively) during business hours may exceed the standard recommended for workplaces (0.05 ppm), representing a cause of possible adverse health effects on employees. The indoor-to-outdoor ozone concentration ratios were greater than 1 in both centres, indicating an important contribution of indoor sources. Formaldehyde levels remained always below the World Health Organisation guideline for indoor air (0.1 mg m(-3)). Total concentrations of volatile organic compounds were also relatively low, in general ranging from around 190 to 300 ppb. The indoor-to-outdoor concentration ratios were in the range between 0.70 and 0.76. Results showed that operation of laser printers can lead to high particulate matter and ozone concentration indoors. Pollutants associated with printing equipment have potential to cause adverse health effects if exposures are sufficiently high. Precautions should be taken to minimise the risks of exposed workers.
引用
收藏
页码:117 / 127
页数:11
相关论文
共 50 条
  • [31] Indoor air quality in Montreal area day-care centres, Canada
    St-Jean, Melissa
    St-Amand, Annie
    Gilbert, Nicolas L.
    Soto, Julio C.
    Guay, Mireille
    Davis, Karelyn
    Gyorkos, Theresa W.
    ENVIRONMENTAL RESEARCH, 2012, 118 : 1 - 7
  • [32] Measurement of Indoor Air Quality Parameters in Daycare Centres in Kuala Lumpur Malaysia
    Cionita, Tezara
    Adam, Nor Mariah
    Jalaludin, Juliana
    Mansor, Mariani
    Siregar, Januar Parlaungan
    ADVANCES IN MECHANICAL AND MANUFACTURING ENGINEERING, 2014, 564 : 245 - +
  • [33] Evaluation of the Indoor Air Quality in Restaurants Before and After a Smoking Ban in Portugal
    Madureira, Joana
    Mendes, Ana
    Santos, Helder
    Vilaca, Jorge
    Neves, Maria Paula
    Mayan, Olga
    Teixeira, Joao Paulo
    INDOOR AND BUILT ENVIRONMENT, 2012, 21 (02) : 323 - 331
  • [34] Air quality assessment in indoor and outdoor environments: A review
    Prabhakaran, J.
    Jayabal, S.
    Kumar, A. Ramesh
    Vinoth, V.
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1260 - 1266
  • [35] Development and application of a protocol for the assessment of indoor air quality
    Möhle, G
    Crump, D
    Brown, V
    Hunter, C
    Squire, R
    Mann, H
    Raw, GJ
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) : 139 - 149
  • [36] Sampling strategies of indoor air quality assessment for offices
    Hui, P.
    Wong, L.
    Mui, K.
    FACILITIES, 2007, 25 (5-6) : 179 - +
  • [37] Indoor air quality: Analytic assessment and employees' perception
    Ferreira, A.
    Jesus, L.
    Figueiredo, J. P.
    Carvalho, A.
    OCCUPATIONAL SAFETY AND HYGIENE, 2013, : 395 - 400
  • [38] Assessment of Indoor Air Quality in US Homes With Infants
    Pickett, Anna Ruth
    Bell, Michelle L.
    EPIDEMIOLOGY, 2011, 22 (01) : S37 - S37
  • [39] A two step model for the assessment of the indoor air quality
    Müller, D
    Bitter, F
    Kasche, J
    Müller, B
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 20 - 25
  • [40] Assessment of link between productivity and indoor air quality
    Dorgan, CE
    Dorgan, CB
    CREATING THE PRODUCTIVE WORKPLACE, 2000, : 107 - 126