In determining the etched track rate in solid-state nuclear track detectors, track lengths should be determined accurately. A method based on surface profilometry is proposed to determine the track lengths in CR-39 detectors through measurements of their replicas. Tracks from alpha particles with an incident energy of 4 MeV have been chosen to demonstrate the method. After irradiation and chemical etching, resin replicas were made from the tracks, of which the heights were measured by the Form Talysurf PGI Profilometer. The results showed that the surface of the replicas were smooth and the heights of the replicas were uniform, so the replicating fluid should have filled the tracks completely and the replicas truly reflected the dimensions of the tracks. The heights of the replicas were conveniently determined from the lateral view of the replicas generated by the Form Talysurf PGI Profilometer.
引用
收藏
页码:93 / 96
页数:4
相关论文
共 50 条
  • [41] ELECTROCHEMICAL DEVELOPMENT OF PARTICLE TRACKS IN CR-39 POLYMER DOSIMETERS
    HADLOCK, DE
    PARKHURST, MA
    YANG, CS
    GROEGER, J
    JOHNSON, JF
    HUANG, SJ
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 185 - 187
  • [42] MEASUREMENTS OF TRANSVERSAL ETCHING RATES OF URANIUM TRACKS IN CR-39
    HEYNA, U
    ENGE, W
    SERMUND, G
    BEAUJEAN, R
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1986, 12 (1-6): : 33 - 36
  • [43] ANNEALING STUDY OF HEAVY-ION TRACKS IN CR-39
    BHATIA, RK
    VIRK, HS
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1987, 25 (7-8) : 282 - 283
  • [44] Uncertainty of an automatic system for counting alpha tracks on CR-39
    Dun-Huang Fan
    Wei-Hai Zhuo
    Bo Chen
    Wei-Yuan Zhang
    NuclearScienceandTechniques, 2017, 28 (11) : 70 - 75
  • [45] Uncertainty of an automatic system for counting alpha tracks on CR-39
    Fan, Dun-Huang
    Zhuo, Wei-Hai
    Chen, Bo
    Zhang, Wei-Yuan
    NUCLEAR SCIENCE AND TECHNIQUES, 2017, 28 (11)
  • [46] STRUCTURE EFFECT IN RESPONSE FUNCTION OF CR-39 DETECTOR
    THANG, NX
    DOAN, TT
    RADIATION MEASUREMENTS, 1995, 25 (1-4) : 185 - 187
  • [47] CALIBRATION OF A CR-39 PLASTIC TRACK DETECTOR FOR THE MEASUREMENT OF RADON AND ITS DAUGHTERS IN DWELLINGS
    KHAN, AJ
    VARSHNEY, AK
    PRASAD, R
    TYAGI, RK
    RAMACHANDRAN, TV
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1990, 17 (04): : 497 - 502
  • [48] PROTON RADIOGRAPHIC CHARACTERISTICS OF THIN CR-39 DETECTOR
    WAHEED, A
    MANZOOR, S
    URLEP, I
    ILIC, R
    CHERUBINI, R
    MOSCHINI, G
    SCHIAVON, P
    KHAN, HA
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1991, 19 (1-4): : 789 - 792
  • [49] A NEW METHOD FOR IDENTIFICATION OF IONS IN A CR-39 DETECTOR
    GRABEZ, B
    VATER, P
    BRANDT, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 42 (02): : 286 - 289
  • [50] A CURING CYCLE FOR DETECTOR-QUALITY CR-39
    ADAMS, JH
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1981, 5 (04): : 348 - 348