A new technique, based on voltages, for fault location on three-terminal transmission lines

被引:22
|
作者
Minambres, JF
Zamora, I
Mazon, AJ
Zorrozua, MA
AlvarezIsasi, R
机构
[1] Department of Electrical Engineering, E.T.S.I.I. y I.T., Basque Country University, 48013 Bilbao, Alda. Urquijo
关键词
fault location; transmission line protection;
D O I
10.1016/0378-7796(96)01054-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new method for fault location on three-terminal transmission lines is described in this paper. Through this method, the faulty line branch is determined and the fault point located in a reliable and simple manner. For this, to reduce mathematical errors, a complete line model including the various characteristics of the network is used and a simple calculation method is applied, based on a new concept referred to as the 'branch factor'. The method only uses the main components (50/60 Hz) of fault and prefault voltage values measured at the three terminals of the transmission line. Moreover, this method is independent of the fault and prefault current, type of fault and fault resistance, as well as the synchronization of recording devices located at the three terminals of the transmission line, and the prefault conditions. This paper also reviews the sensitivity of this method to errors in input data.
引用
下载
收藏
页码:143 / 151
页数:9
相关论文
共 50 条
  • [21] Adaptive Fault Location for Three-Terminal Lines Using Synchrophasors
    Al-Mohammed, A. H.
    Abido, M. A.
    2014 IEEE INTERNATIONAL WORKSHOP ON APPLIED MEASUREMENTS FOR POWER SYSTEMS PROCEEDINGS (AMPS), 2014, : 69 - +
  • [22] Synchrophasor Based Novel Fault Location Algorithm for Three-Terminal Transmission Line
    Sontakke, Maitreyee
    Hinge, Trupti
    Dambhare, Sanjay
    HELIX, 2020, 10 (02): : 9 - 14
  • [23] A New Fault Location Algorithm Based on Positive Sequence Current Difference for Double-circuit Three-terminal Transmission Lines
    Zhang S.
    Li Y.
    Chen X.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2018, 38 (05): : 1488 - 1495
  • [24] A New Fault Location Algorithm Based on Positive Sequence Current Difference for Double-circuit Three-terminal Transmission Lines
    ZHANG Siqi
    LI Yongli
    CHEN Xiaolong
    中国电机工程学报, 2018, 38 (05) : 1609 - 1609
  • [25] A new PMU-based fault location algorithm for three-terminal
    Shen Hong-yu
    Zhang Wen-jun
    Duan Yu-bo
    Xu Jian-jun
    ADVANCES IN CHEMICAL, MATERIAL AND METALLURGICAL ENGINEERING, PTS 1-5, 2013, 634-638 : 3925 - 3929
  • [26] An Iterative Parameter-Free Fault Location Method on Three-Terminal Untransposed Transmission Lines
    Lu, Dian
    Liu, Yu
    Lu, Dayou
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [27] PMU-Based fault location method for Three-terminal transmission lines with outage of one line branch
    Saber, Ahmed
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 182
  • [28] A new fault location method for single-circuit three-terminal transmission lines based onfault branch determination and iterative calculation
    Chen X.
    Yu L.
    Pei D.
    Yuan S.
    Xue S.
    Jiang Y.
    Li S.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (20): : 1 - 11
  • [29] Fault location on three-terminal lines associated with current differential relays
    Rosolowski, E.
    Izykowski, J.
    Balcerek, P.
    Fulczyk, M.
    Saha, M. M.
    PRZEGLAD ELEKTROTECHNICZNY, 2007, 83 (04): : 120 - 124
  • [30] Fault location of hybrid three-terminal HVDC transmission line based on improved LMD
    Gao, Shuping
    Xu, Zhenxi
    Song, Guobing
    Shao, Mingxing
    Jiang, Yuanyue
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 201