Cluster models of dose-volume effects

被引:25
|
作者
Thames, HD
Zhang, M
Tucker, SL
Liu, HH
Dong, L
Mohan, R
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
NTCP; serial models; parallel models; radiotherapy; dose-volume;
D O I
10.1016/j.ijrobp.2004.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Describe cluster models, normal-tissue complication probability models in which both the number and the spatial location of radiation-sterilized functional subunits play a role in defining complication probability. Methods and Materials: Computer simulation was used to determine the maximum size cluster of sterilized subunits associated with a given dose distribution. Complications were associated with large clusters. Results: Cluster models showed a volume effect, as increasing effect for constant dose when the volume increased or constant effect when the dose was reduced with increasing volume. Cluster models gave similar results to existing models when tissues were irradiated uniformly. With inhomogeneous dose distributions, on the other hand, different spatial distributions of "hot spots" may lead to different predictions of complication probability by cluster models. The result was that a higher complication probability resulted when hot spots were contiguous (clustered) than when they were dispersed, even if both situations are characterized by the same dose-volume histogram. A potential advantage of cluster models is to provide an easy, internally consistent way to predict complications arising from the inhomogeneous dose distributions that sometimes arise with intensity-modulated radiotherapy. Conclusion: Cluster models offer a new way to quantify complication probability in treatment situations in which a wide variety of hot-spot distributions occur. (C) 2004 Elsevier Inc.
引用
收藏
页码:1491 / 1504
页数:14
相关论文
共 50 条
  • [41] The impact of heart irradiation on dose-volume effects in the rat lung
    van Luijk, Peter
    Faber, Hette
    Meertens, Harm
    Schippers, Jacobus M.
    Langendijk, Johannes A.
    Brandenburg, Sytze
    Kampinga, Harm H.
    Coppes, Robert P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (02): : 552 - 559
  • [42] Dose-volume effects for normal tissues in external radiotherapy: Pelvis
    Fiorino, Claudio
    Valdagni, Riccardo
    Rancati, Tiziana
    Sanguineti, Giuseppe
    [J]. RADIOTHERAPY AND ONCOLOGY, 2009, 93 (02) : 153 - 167
  • [43] DOSE-VOLUME DISTRIBUTIONS - A NEW APPROACH TO DOSE-VOLUME HISTOGRAMS IN 3-DIMENSIONAL TREATMENT PLANNING
    NIEMIERKO, A
    GOITEIN, M
    [J]. MEDICAL PHYSICS, 1994, 21 (01) : 3 - 11
  • [44] Treatment plan evaluation using dose-volume histogram (DVH) and spatial dose-volume histogram (zDVH)
    Cheng, CW
    Das, IJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 43 (05): : 1143 - 1150
  • [45] Dose-volume histograms for bladder and rectum
    Ting, JY
    Wu, XD
    Fiedler, JA
    Yang, CC
    Watzich, ML
    Markoe, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 38 (05): : 1105 - 1111
  • [46] DOSE-VOLUME EVALUATION OF TREATMENT PLANS
    GILLIN, MT
    KLINE, RW
    GRIMM, DF
    LOFY, DJ
    [J]. MEDICAL PHYSICS, 1983, 10 (04) : 515 - 515
  • [47] Pitfalls in Dose-Volume Histogram Computations
    Kaster, F.
    Aznar, M.
    Kadir, T.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [48] Dose-volume modeling of treatment outcome
    Jackson, A
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2072 - 2072
  • [49] Reconsidering the definition of a dose-volume histogram
    Nioutsikou, E
    Webb, S
    Panakis, N
    Bortfeld, T
    Oelfke, U
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (11): : L17 - L19
  • [50] Evaluation of two dose-volume histogram reduction models for the prediction of radiation pneumonitis
    Kwa, SLS
    Theuws, CM
    Wagenaar, A
    Damen, EMF
    Boersma, LJ
    Baas, P
    Muller, SH
    Lebesque, JV
    [J]. RADIOTHERAPY AND ONCOLOGY, 1998, 48 (01) : 61 - 69