Development of a preclinical CCD- based temperature modulated fluorescence tomography platform

被引:4
|
作者
Nouizi, Farouk [1 ,2 ]
Erkol, Hakan [3 ]
Nikkhah, Deniz [1 ]
Kwong, Tiffany C. [1 ]
Gulsen, Gultekin [1 ,2 ]
机构
[1] Univ Calif Irvine, Dept Radiol Sci, Tu & Yuen Ctr Funct Oncoimaging, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Chao Family Comprehens Canc Ctr, Irvine, CA 92697 USA
[3] Bogazici Univ, Dept Phys, TR-34342 Istanbul, Turkey
基金
美国国家卫生研究院;
关键词
DIFFUSE OPTICAL TOMOGRAPHY; QUANTITATIVE ACCURACY; RESOLUTION; INFORMATION; ALGORITHM;
D O I
10.1364/BOE.470723
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In preclinical research, fluorescence molecular tomography (FMT) is the most sensitive imaging modality to interrogate whole-body and provide 3D distribution of fluorescent contract agents. Despite its superior sensitivity, its mediocre spatial-resolution has been the main barrier to its clinical translation. This limitation is mainly due to the high scattering of optical photons in biological tissue together with the limited boundary measurements that lead to an undetermined and ill-posed inverse problem. To overcome the limitations of FMT, we previously introduced a novel method termed, Temperature Modulated Fluorescence Tomography (TMFT). TMFT utilizes thermos-sensitive fluorescent agents (ThermoDots) as a key component and localizes them with high-intensity focused ultrasound (HIFU). Scanning the focused HIFU beam having a diameter phi= 1.3 mm across the tissue while monitoring the variation in the measured fluorescence signals reveals the position of the ThermoDots with high spatial accuracy. We have formerly built a prototype TMFT system that uses optical fibers for detection. In this paper, we present an upgraded version using a CCD camera-based detection that enables non-contact imaging. In this version, the animal under investigation is placed on an ultrasound transparent membrane, which eliminates the need for its immersion in optical matching fluids that were required by the fiber-based system. This CCD-based system will pave the way for convenient and wide-spread use of TMFT in preclinical research. Its performance validation on phantom studies demonstrates that high spatial-resolution (similar to 1.3 mm) and quantitative accuracy in recovered fluorophore concentration (<3% error) can be achieved.
引用
收藏
页码:5740 / 5752
页数:13
相关论文
共 50 条
  • [21] Study ofindicators for the development of fluorescence based optical fiber temperature sensors
    Garcia Moreda, Francisco J.
    Arregui, Francisco J.
    Achaerandio, Miguel
    Matias, Ignacio R.
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2006, 118 (1-2): : 425 - 432
  • [22] The Development of Temperature Measurement System in Laser Molten Pool Based on Monochrome CCD with High Speed
    Wu Yunxia
    Shi Shihong
    Yu Jiali
    Yu Lingling
    Wu Jiongjie
    [J]. MACHINE DESIGN AND MANUFACTURING ENGINEERING, 2012, 566 : 431 - 434
  • [23] Development of Ultrasonic Modulation Probe for Fluorescence Tomography Based on Acousto-Optic Effect
    Trinh Quang Duc
    Kaneta, Shunsuke
    Kobayashi, Masaki
    [J]. INTERNATIONAL JOURNAL OF OPTICS, 2011, 2011
  • [24] Development of A CCD-based Optical Computed Tomography Scanner Used in 3D Gel Dosimetry
    Chang, Yuan-Jen
    Tseng, Hung-Li
    Chen, Chin-Hsing
    Tan, Sun-Yen
    Hsieh, Bor-Tsung
    Chang, Wei-Lun
    Huang, Wen-Tzeng
    [J]. MECHATRONICS AND APPLIED MECHANICS II, PTS 1 AND 2, 2013, 300-301 : 1632 - +
  • [25] Development of CCD-based optical computed tomography and comparison with single-beam optical CT scanner
    Chang, Y. J.
    [J]. 8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [26] Development and optimisation of a preclinical cone beam computed tomography-based radiomics workflow for radiation oncology research
    Brown, Kathryn H.
    Payan, Neree
    Osman, Sarah
    Ghita, Mihaela
    Walls, Gerard M.
    Patallo, Ileana Silvestre
    Schettino, Giuseppe
    Prise, Kevin M.
    McGarry, Conor K.
    Butterworth, Karl T.
    [J]. PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2023, 26
  • [27] Preclinical development of spherical nucleic acids, a novel RNAi-based nanomedicinal platform, as anti-glioma therapeutics
    Stegh, Alexander H.
    [J]. CANCER RESEARCH, 2012, 72
  • [28] Preclinical development of a platform for enzyme therapy in the CNS of MPS I and MPS II patients based on intrathecal AAV delivery
    Hinderer, Christian
    Hordeaux, Juliette
    Katz, Nathan
    Bell, Peter
    Goode, Tamara
    Haskins, Mark E.
    Wilson, James M.
    [J]. MOLECULAR GENETICS AND METABOLISM, 2018, 123 (02) : S64 - S64
  • [29] Development of an Electro Impedance Tomography-based Platform for Measurement of burial Depth of Cables in Subsea Sediments
    Schuldei, Andreas
    Suthau, Tim
    John, Fabian
    Ardelt, Gunther
    Hellbrueck, Horst
    [J]. OCEANS 2019 - MARSEILLE, 2019,
  • [30] The development of a dual-mode optical temperature sensor based on fluorescence intensity ratio and lifetime
    Yu, Meng-Han
    Zhao, Dan
    Zhang, Rui-Juan
    Yao, Qing-Xia
    Jia, Lei
    Zong, Qiu
    [J]. CERAMICS INTERNATIONAL, 2024, 50 (07) : 11766 - 11775