Thermal conductivity in the three layered regions of micro porous layer coated porous transport layers for the PEM fuel cell

被引:40
|
作者
Burheim, Odne S. [1 ]
Crymble, Gregory A. [2 ]
Bock, Robert [1 ,3 ]
Hussain, Nabeel [2 ]
Pasupathi, Sivakumar [4 ]
du Plessis, Anton [5 ]
le Roux, Stephan [5 ]
Seland, Frode [3 ]
Su, Huaneng [4 ]
Pollet, Bruno G. [4 ,6 ]
机构
[1] HiST Sor Trondelag Univ Coll, Dept Elect & Computat Engn, Trondheim, Norway
[2] Univ Cape Town, Dept Chem Engn, ZA-7700 Rondebosch, South Africa
[3] Norwegian Univ Sci & Technol, Dept Mat Sci & Technol, N-7491 Trondheim, Norway
[4] Univ Western Cape, Fac Nat Sci, SAIAMC, Cape Town, South Africa
[5] Univ Stellenbosch, ZA-7600 Stellenbosch, South Africa
[6] Eau2Energy, Nottingham NG14 6DX, England
关键词
Polymer electrolyte membrane fuel cell; Thermal conductivity; Micro porous layer; Gas diffusion layer; Computer tomography; TEMPERATURE PROFILES; MICROPOROUS LAYER; CONTACT RESISTANCE;
D O I
10.1016/j.ijhydene.2015.07.169
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Thermal conductivity of the polymer electrolyte membrane fuel cell (PEMFC) components has achieved increased attention over the past decade. Despite the fact that the PEMFC itself (between the gas flow plates) is less than a millimetre in thickness, several C temperature differences can arise inside it during operation. These temperature differences mainly arise across the porous transport layers (PTL) often also referred to as gas diffusion layers (GDL). Several research efforts have led to a good understanding of the thermal conductivity of the PTL; in particular to how this property changes with compression, temperature, PTFE content, different fabrics, and water content. Far less attention has been given to the thermal conductivity of the much thinner layered micro porous layer (MPL) and in particular to the thermal conductivity of the transitional region between the PTL and the MPL. In this study we have used X-ray computer tomography (XCT), scanning electron microscopy (SEM), and thermal conductivity measurements to show that a MPL coated PTL is actually a three layered structure where the PTL is on one side, the MPL on the other, and a composite region consisting of the MPL as a matrix with the PTL fibres in the middle. We have shown that the thermal conductivity of the MPL-PTL-composite region is much larger than for the two others and that temperature differences inside this layer can be neglected compared to the regions where it is MPL-only and PTL-only. We have also shown that the MPL has a significantly lower thermal conductivity than the other two layers. In light of this research, the MPL of the commercial SGL should be integrated into the GDL in order to have lower temperature deviations in the PEMFC. A relevant literature review is included. Copyright (C) 2015, The Authors. Published by Elsevier Ltd on behalf of Hydrogen Energy Publications, LLC. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:16775 / 16785
页数:11
相关论文
共 50 条
  • [1] Ageing and thermal conductivity of Porous Transport Layers used for PEM Fuel Cells
    Burheim, O. S.
    Ellila, G.
    Fairweather, J. D.
    Labouriau, A.
    Kjelstrup, S.
    Pharoah, J. G.
    [J]. JOURNAL OF POWER SOURCES, 2013, 221 : 356 - 365
  • [2] MASS TRANSPORT MEASUREMENTS IN POROUS TRANSPORT LAYERS OF A PEM FUEL CELL
    Pant, Lalit M.
    Mitra, Sushanta K.
    Secanell, Marc
    [J]. PROCEEDINGS IF THE ASME 9TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2011, VOL 1, 2012, : 257 - +
  • [3] Scaling the Water Percolation in PEM Fuel Cell Porous Transport Layers
    Medici, E. F.
    Allen, J. S.
    [J]. POROUS MEDIA AND ITS APPLICATIONS IN SCIENCE, ENGINEERING AND INDUSTRY, 2010, 1254 : 236 - 241
  • [4] On effective transport coefficients in PEM fuel cell electrodes: Anisotropy of the porous transport layers
    Pharoah, J. G.
    Karan, K.
    Sun, W.
    [J]. JOURNAL OF POWER SOURCES, 2006, 161 (01) : 214 - 224
  • [5] Liquid behavior across porous transport layer in PEM fuel cell cathode
    Jiao, Kui
    Zhou, Biao
    [J]. Proceedings of the 4th International Conference on Fuel Cell Science, Engineering, and Technology, Pts A and B, 2006, : 983 - 991
  • [6] Effect of Polytetrafluoroethylene (PTFE) and micro porous layer (MPL) on thermal conductivity of fuel cell gas diffusion layers: Modeling and experiments
    Sadeghifar, Hamidreza
    Djilali, Ned
    Bahrami, Majid
    [J]. JOURNAL OF POWER SOURCES, 2014, 248 : 632 - 641
  • [7] Three dimensional model of oxygen transport in a porous diffuser of a PEM fuel cell
    Zhukovsky, KV
    [J]. AICHE JOURNAL, 2003, 49 (12) : 3029 - 3036
  • [8] Thermal conductivity and temperature profiles of the micro porous layers used for the polymer electrolyte membrane fuel cell
    Burheim, Odne S.
    Su, Huaneng
    Pasupathi, Sivakumar
    Pharoah, Jon G.
    Pollet, Bruno G.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2013, 38 (20) : 8437 - 8447
  • [9] EFFECT OF POROSITY AND THERMAL CONDUCTIVITY OF A POROUS TRANSPORT LAYER ON SATURATION AND THERMAL TRANSPORT IN A LOW-TEMPERATURE FUEL CELL
    Konduru, Vinaykumar
    Medici, Ezequiel
    Allen, Jeffrey S.
    [J]. PROCEEDINGS OF THE ASME 11TH FUEL CELL SCIENCE, ENGINEERING, AND TECHNOLOGY CONFERENCE, 2013, 2014,
  • [10] Modeling the Effects of the Cathode Micro-Porous Layer on the Performance of a PEM Fuel Cell
    Wang, Xuhai
    Nguyen, Trung Van
    [J]. PROTON EXCHANGE MEMBRANE FUEL CELLS 8, PTS 1 AND 2, 2008, 16 (02): : 3 - +