Intravascular ultrasound tissue harmonic imaging in vivo

被引:29
|
作者
Frijlink, Martijn E. [1 ]
Goertz, David E.
van Damme, Luc C. A.
Krams, Rob
van der Steen, Antonius F. W.
机构
[1] Erasmus Univ, Med Ctr, Rotterdam, Netherlands
[2] Interuniv Cardiol Inst, Utrecht, Netherlands
关键词
D O I
10.1109/TUFFC.2006.116
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Tissue harmonic imaging (THI) has been shown to increase image quality of medical ultrasound in the frequency range from 2 to 10 MHz and might, therefore, also be used to improve image quality in intravascular ultrasound (IVUS). In this study we constructed a prototype IVUS system that could operate in both fundamental frequency and second harmonic imaging modes. This system uses a conventional, continuously rotating, single-element IVUS catheter and was operated in fundamental 20 MHz, fundamental 40 MHz, and harmonic 40 MHz modes (transmit 20 MHz, receive 40 MHz). Hydrophone beam characterization measurements demonstrated the build-up of a second harmonic signal as a function of increasing pressure. Imaging experiments were conducted in both a tissue-mimicking phantom and in an atherosclerotic animal model in vivo. Acquisitions of fundamental 20 and 40 MHz and second harmonic acquisitions resulted in cross sections of the phantom and a rabbit aorta. The harmonic results of the imaging experiments showed the feasibility of intravascular THI with a conventional IVUS catheter both in a phantom and in vivo. The harmonic acquisitions also showed the potential of THI to reduce image artifacts compared to fundamental imaging.
引用
收藏
页码:1844 / 1852
页数:9
相关论文
共 50 条
  • [1] Intravascular ultrasound tissue harmonic imaging in vivo
    Frijlink, ME
    Goertz, DE
    van Damme, LCA
    Krams, R
    van der Steen, AFW
    [J]. 2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1118 - 1121
  • [2] Intravascular ultrasound tissue harmonic imaging: A simulation study
    Frijlink, M. E.
    Goertz, D. E.
    Bouakaz, A.
    van der Steen, A. F. W.
    [J]. ULTRASONICS, 2006, 44 : E185 - E188
  • [3] Transducer for harmonic intravascular ultrasound imaging
    Vos, HJ
    Frijlink, ME
    Droog, E
    Goertz, DE
    Blacquière, G
    Gisolf, A
    de Jong, N
    van der Steen, AFW
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (12) : 2418 - 2422
  • [4] Combined chirp coded tissue harmonic and fundamental ultrasound imaging for intravascular ultrasound: 20-60 MHz phantom and ex vivo results
    Park, Jinhyoung
    Li, Xiang
    Zhou, Qifa
    Shung, K. Kirk
    [J]. ULTRASONICS, 2013, 53 (02) : 369 - 376
  • [5] A simulation study on tissue harmonic imaging with a single-element intravascular ultrasound catheter
    Frijlink, Martijn E.
    Goertz, David E.
    Bouakaz, Ayache
    van der Steen, Antonius F. W.
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2006, 120 (03): : 1723 - 1731
  • [6] Strain Imaging with Intravascular Ultrasound: An In Vivo Study
    Khaled, Walaa
    Perrey, Christian
    Ermert, Helmut
    Bojara, Waldemar
    Lindstaedt, Michael
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 1313 - +
  • [7] In vivo intravascular imaging with OCT: Comparison with ultrasound
    Li, XD
    Gold, H
    Weissman, N
    Pitris, C
    Saunders, K
    Ghanti, R
    Fujimoto, J
    Brezinski, M
    [J]. BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 32 - 34
  • [8] Intravascular Ultrasound Transducer by Using Polarization Inversion Technique for Tissue Harmonic Imaging: Modeling and Experiments
    Sung, Jin Ho
    Jeong, Eun Young
    Jeong, Jong Seob
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2020, 67 (12) : 3380 - 3391
  • [9] Conventional ultrasound and tissue harmonic imaging
    Kessler, C
    Jenett, MA
    Hoehmann, M
    Hau, M
    Hahn, D
    [J]. RADIOLOGY, 1999, 213P : 397 - 397
  • [10] IN-VIVO THROMBOGENICITY OF INTRAVASCULAR ULTRASOUND IMAGING CATHETERS
    BOLZ, KD
    NORDBY, A
    [J]. ACTA RADIOLOGICA, 1995, 36 (03) : 280 - 283