Combined chirp coded tissue harmonic and fundamental ultrasound imaging for intravascular ultrasound: 20-60 MHz phantom and ex vivo results

被引:19
|
作者
Park, Jinhyoung [1 ]
Li, Xiang [1 ]
Zhou, Qifa [1 ]
Shung, K. Kirk [1 ]
机构
[1] Univ So Calif, Dept Biomed Engn, NIH Resource Med Ultrason Transducer Technol, Los Angeles, CA 90089 USA
关键词
Chirp coded tissue harmonic imaging; Chirp coded excitation; Intravascular ultrasound imaging; ARTIFACTS;
D O I
10.1016/j.ultras.2012.07.003
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The application of chirp coded excitation to pulse inversion tissue harmonic imaging can increase signal to noise ratio. On the other hand, the elevation of range side lobe level, caused by leakages of the fundamental signal, has been problematic in mechanical scanners which are still the most prevalent in high frequency intravascular ultrasound imaging. Fundamental chirp coded excitation imaging can achieve range side lobe levels lower than -60 dB with Hanning window, but it yields higher side lobes level than pulse inversion chirp coded tissue harmonic imaging (PI-CTHI). Therefore, in this paper a combined pulse inversion chirp coded tissue harmonic and fundamental imaging mode (CPI-CTHI) is proposed to retain the advantages of both chirp coded harmonic and fundamental imaging modes by demonstrating 20-60 MHz phantom and ex vivo results. A simulation study shows that the range side lobe level of CPI-CTHI is 16 dB lower than PI-CTHI, assuming that the transducer translates incident positions by 50 mu m when two beamlines of pulse inversion pair are acquired. CPI-CTHI is implemented for a proto-typed intravascular ultrasound scanner capable of combined data acquisition in real-time. A wire phantom study shows that CPI-CTHI has a 12 dB lower range side lobe level and a 7 dB higher echo signal to noise ratio than PI-CTHI, while the lateral resolution and side lobe level are 50 mu m finer and -3 dB less than fundamental chirp coded excitation imaging respectively. Ex vivo scanning of a rabbit trachea demonstrates that CPI-CTHI is capable of visualizing blood vessels as small as 200 mu m in diameter with 6 dB better tissue contrast than either PI-CTHI or fundamental chirp coded excitation imaging. These results clearly indicate that CPI-CTHI may enhance tissue contrast with less range side lobe level than PI-CTHI. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:369 / 376
页数:8
相关论文
共 14 条
  • [1] Intravascular ultrasound tissue harmonic imaging in vivo
    Frijlink, ME
    Goertz, DE
    van Damme, LCA
    Krams, R
    van der Steen, AFW
    [J]. 2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1118 - 1121
  • [2] Intravascular ultrasound tissue harmonic imaging in vivo
    Frijlink, Martijn E.
    Goertz, David E.
    van Damme, Luc C. A.
    Krams, Rob
    van der Steen, Antonius F. W.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (10) : 1844 - 1852
  • [3] A 20-40 MHz ultrasound transducer for intravascular harmonic imaging
    Vos, HJ
    Frijlink, ME
    Droog, E
    Goertz, DE
    Blacquière, G
    Gisolf, A
    De Jong, N
    Van der Steen, AFW
    [J]. 2004 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-3, 2004, : 1966 - 1969
  • [4] Ex vivo validation of 45 MHz intravascular ultrasound backscatter tissue characterization
    Campos, Carlos M.
    Fedewa, Russell J.
    Garcia-Garcia, Hector M.
    Vince, D. Geoffrey
    Margolis, M. Pauliina
    Lemos, Pedro A.
    Stone, Gregg W.
    Serruys, Patrick W.
    Nair, Anuja
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (10) : 1112 - 1119
  • [5] Ultrasound tissue harmonic imaging using nonlinear chirp coded excitation: in vitro study and analysis
    Kim, Pilsu
    Song, Hyunwoo
    Bael, Sua
    Song, Tai-kyong
    [J]. 2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
  • [6] A 35 MHz/105 MHz Dual-Element Focused Transducer for Intravascular Ultrasound Tissue Imaging Using the Third Harmonic
    Lee, Junsu
    Moon, Ju-Young
    Chang, Jin Ho
    [J]. SENSORS, 2018, 18 (07)
  • [7] Combined ultrasound and photoacoustic imaging to detect and stage deep vein thrombosis: phantom and ex vivo studies
    Karpiouk, Andrei B.
    Aglyamov, Salavat R.
    Mallidi, Srivalleesha
    Shah, Jignesh
    Scott, W. Guy
    Rubin, Jonathan M.
    Emelianov, Stanislav Y.
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (05)
  • [8] Fundamental Analysis and Ex Vivo Validation of Thermal Lesion Mapping Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
    Hou, Gary Y.
    Luo, Jianwen
    Maleke, Caroline
    Vappou, Jonathan
    Marquet, Fabrice
    Konofagou, Elisa E.
    [J]. 11TH INTERNATIONAL SYMPOSIUM ON THERAPEUTIC ULTRASOUND, 2012, 1481 : 137 - 142
  • [9] Pulse Inversion Chirp Coded Tissue Harmonic Imaging (PI-CTHI) of Zebrafish Heart Using High Frame Rate Ultrasound Biomicroscopy
    Jinhyoung Park
    Ying Huang
    Ruimin Chen
    Jungwoo Lee
    Thomas M. Cummins
    Qifa Zhou
    Ching-Ling Lien
    K. K. Shung
    [J]. Annals of Biomedical Engineering, 2013, 41 : 41 - 52
  • [10] Pulse Inversion Chirp Coded Tissue Harmonic Imaging (PI-CTHI) of Zebrafish Heart Using High Frame Rate Ultrasound Biomicroscopy
    Park, Jinhyoung
    Huang, Ying
    Chen, Ruimin
    Lee, Jungwoo
    Cummins, Thomas M.
    Zhou, Qifa
    Lien, Ching-Ling
    Shung, K. K.
    [J]. ANNALS OF BIOMEDICAL ENGINEERING, 2013, 41 (01) : 41 - 52