Investigation of a high-resolution detector for wholebody PET imaging

被引:0
|
作者
Surti, Suleman [1 ]
Kuhn, Austin [1 ]
Karp, Joel S. [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5 | 2005年
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Increased focus towards improved detector spatial resolution in PET (for whole-body as well as small animal imaging) has led to the use of smaller crystals in some form of light sharing detector design. We have performed simulations for a generic whole-body scanner with varying crystals sizes in order to better understand the limitations in achieving good uniform spatial resolution using discrete crystal based detectors in a whole-body scanner. These results show that using small 2-mm crystals leads to a noticeable improvement in the reconstructed spatial resolution of whole-body scanners due to better sampling in the sinogram. Over the years we have investigated using large continuous detectors with Anger positioning, cutting slots in continuous detectors to produce semi-continuous detectors, and more recently pixelated Anger-logic detectors. Our aim is to develop a new detector concept that incorporates high detector sampling with very good intrinsic spatial resolution to produce high resolution reconstructed images. In this work we investigate three different techniques for achieving our goals: Using regions-of-interest (ROI) which are half the crystal size in the crystal identification map. Dual layers of 4x4x.15-mm3 offset crystals. Large continuous Crystals with 3D positioning of interaction (313 crystals) using maximum likelihood positioning algorithm. Our results show a reasonable improvement in spatial resolution (1-mm at center) using smaller ROI's and a similar improvement in off-center positions using the offset crystals. A more noticeable improvement is observed with the 3D crystal detector where the resolution seems to be intrinsically limited by the physics of positron annihilation and amount of Compton scatter in the crystal.
引用
收藏
页码:1601 / 1605
页数:5
相关论文
共 50 条
  • [41] INVESTIGATION OF COUNT RATE AND DEADTIME CHARACTERISTICS OF A HIGH-RESOLUTION PET SYSTEM
    GERMANO, G
    HOFFMAN, EJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (05) : 836 - 846
  • [42] Quantitative capability of a high-resolution PET scanner for primate imaging.
    Fahey, FH
    Gage, HD
    Buchheimer, NC
    Smith, HC
    Bounds, MC
    Morton, KA
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (05) : 160P - 160P
  • [43] Design of a wholebody high resolution PET with changeable transaxial and axial fields of view.
    Wong, WH
    Uribe, J
    Li, H
    Baghaei, H
    Wang, Y
    Aykac, M
    Liu, Y
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 98P - 98P
  • [44] A HIGH-RESOLUTION BETA- DETECTOR
    CHARON, Y
    CUZON, JC
    TRICOIRE, H
    VALENTIN, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 748 - 753
  • [45] A miniaturized detector for high-resolution SEMPA
    R. Frömter
    H.P. Oepen
    J. Kirschner
    Applied Physics A, 2003, 76 : 869 - 871
  • [46] A miniaturized detector for high-resolution SEMPA
    Frömter, R
    Oepen, HP
    Kirschner, J
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2003, 76 (06): : 869 - 871
  • [47] HIGH-RESOLUTION CDTE DETECTOR SYSTEMS
    REDUS, R
    SQUILLANTE, M
    LUND, J
    CIRIGNANO, L
    WAER, P
    PANTAZIS, J
    HUBER, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 59 - 59
  • [48] Performance of a high-resolution depth encoding PET detector using barium sulfate reflector
    Kuang, Zhonghua
    Wang, Xiaohui
    Li, Cheng
    Deng, Xinhan
    Feng, Kai
    Hu, Zhanli
    Fu, Xin
    Ren, Ning
    Zhang, Xianming
    Zheng, Yunfei
    Liang, Dong
    Liu, Xin
    Zheng, Hairong
    Yang, Yongfeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (15): : 5945 - 5958
  • [49] Characterization of a high-resolution hybrid DOI detector for a dedicated breast PET/CT scanner
    Godinez, Felipe
    Chaudhari, Abhijit J.
    Yang, Yongfeng
    Farrell, Richard
    Badawi, Ramsey D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (11): : 3435 - 3449
  • [50] Design of High-Resolution Brain PET Using Dual-Layer DOI Detector
    Lim, W.
    Lee, S.
    Jung, J. H.
    Choi, Y.
    INTERNAL MEDICINE JOURNAL, 2022, 52 : 33 - 34