Dosimetric effects of roll rotational setup errors on lung stereotactic ablative radiotherapy using volumetric modulated arc therapy

被引:11
|
作者
Lee, Jaegi [1 ,2 ]
Kim, Jung-In [2 ,3 ,4 ,5 ]
Ye, Sung-Joon [1 ,3 ]
Kim, Hak Jae [3 ,4 ,6 ]
Carlson, Joel [1 ,2 ]
Park, Jong Min [2 ,3 ,4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch Convergence Sci & Technol, Dept Transdisciplinary Studies, Program Biomed Radiat Sci, Seoul, South Korea
[2] Seoul Natl Univ, Coll Med, Biomed Res Inst, Seoul, South Korea
[3] Seoul Natl Univ Hosp, Dept Radiat Oncol, Seoul 110744, South Korea
[4] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[5] Adv Inst Convergence Technol, Ctr Convergence Res Robot, Suwon, South Korea
[6] Seoul Natl Univ, Dept Radiat Oncol, Coll Med, Seoul, South Korea
来源
BRITISH JOURNAL OF RADIOLOGY | 2015年 / 88卷 / 1055期
关键词
BODY RADIATION-THERAPY; IMAGE-GUIDED RADIOTHERAPY; CONE-BEAM CT; CANCER; METASTASES; GUIDANCE; POSITION; PATIENT;
D O I
10.1259/bjr.20140862
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the dosimetric effects of roll-rotational setup errors of stereotactic ablative radiotherapy (SABR) for lung cancer using volumetric modulated arc therapy (VMAT). Methods: A total of 23 lung SABR cases were evaluated retrospectively. Each of the planning CT images was intentionally rotated by +/- 1 degrees, +/- 2 degrees and +/- 3 degrees. After that, to simulate the translational couch correction, rotated CT images were moved along the x, y and z axis to match the centroid of the target volume in the rotated CT images with that in the original CT images. The differences in D-95% and V-100% of the target volume, D-0.35cc of spinal cord, D-0.35cc and D-5cc of oesophagus and V-20Gy of lung between the original and the rotated CT images were calculated. Results: The average differences in D95% and V100% of target volume, D0.35cc of spinal cord, D0.35cc and D5cc of oesophagus and V-20Gy of lung were -0.3% +/- 0.4% and -0.7% +/- 2.4%, 1.6 +/- 27.9 cGy, -1.6 +/- 37.6cGy, 15.9 +/- 25.3cGy and 0.0%+/- 0.1%, respectively. The dosimetric changes in organs at risk (OARs) near the target volume were sometimes considerable due to roll-rotational setup errors, despite the translational correction, and those were patient specific. Conclusion: In the case of coplanar VMAT for lung SABR, dosimetric changes to the target volume due to roll-rotational setup errors could be compensated by translational correction, whereas those to the OARs could not in some cases. Advances in knowledge: Roll-rotational setup errors would increase the dose to OARs despite the translational correction.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Critical Structure Sparing in Stereotactic Ablative Radiotherapy for Central Lung Lesions: Helical Tomotherapy vs. Volumetric Modulated Arc Therapy
    Chi, Alexander
    Ma, Pan
    Fu, Guishan
    Hobbs, Gerry
    Welsh, James S.
    Nguyen, Nam P.
    Jang, Si Young
    Dai, Jinrong
    Jin, Jing
    Komaki, Ritsuko
    PLOS ONE, 2013, 8 (04):
  • [32] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yucel
    JOURNAL OF CLINICAL PRACTICE AND RESEARCH, 2023, 45 (01): : 19 - 24
  • [33] Comparison of the Dosimetric Planning Efficiency of Dynamic Conformal Arc and Volumetric Modulated Arc Therapy Techniques for Stereotactic Body Radiotherapy of Lung Cancer Using Internal Target Volume
    Saglam, Yuecel
    ERCIYES MEDICAL JOURNAL, 2023, 45 (01) : 19 - 24
  • [34] Dosimetric Effect of Calculation Grid Size on Epidural Space in Spine Stereotactic Body Radiotherapy Using Volumetric Modulated Arc Therapy
    Shimizu, H.
    Sasaki, K.
    Tanaka, H.
    Aoyama, T.
    Tachibana, H.
    Koide, Y.
    Kodaira, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E773 - E773
  • [35] Fractionated stereotactic radiotherapy with volumetric modulated arc therapy for pituitary adenoma
    Castano Cantos, A.
    Rodriguez Roldan, M.
    Gonzalez del Portillo, E.
    Garrido Botella, I.
    Teja Ubach, M.
    Gonzalez Cantero, M.
    Rosel Aller, R.
    Deben Mendez, B.
    Matute Martin, R.
    Morera Lopez, R.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S898 - S899
  • [36] Dosimetric impact of translational and rotational setup errors for spine stereotactic body radiotherapy: A phantom study
    Sasaki, Makoto
    Nakamura, Mitsuhiro
    Mukumoto, Nobutaka
    Nakata, Manabu
    Hiraoka, Masahiro
    MEDICAL DOSIMETRY, 2018, 43 (04) : 320 - 326
  • [37] A review of stereotactic body radiotherapy - is volumetric modulated arc therapy the answer?
    Sapkaroski, Daniel
    Osborne, Catherine
    Knight, Kellie A.
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2015, 62 (02): : 142 - 151
  • [38] Dosimetric Feasibility of Stereotactic Ablative Radiotherapy in Patients with Ventricular Tachycardia Using Intensity Modulated Proton Therapy
    Ren, X. Y.
    Gao, X.
    He, P.
    Zhao, Z.
    Ma, M.
    Bai, Y.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E231 - E231
  • [39] Dosimetric impact of breathing motion in lung stereotactic body radiotherapy treatment using image-modulated radiotherapy and volumetric modulated arc therapy (vol 83, e251, 2012)
    Rao, M.
    Wu, J.
    Cao, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (05): : 859 - 859
  • [40] VOLUMETRIC-MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY OF LUNG TUMORS: A COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY TECHNIQUES
    Holt, Andrea
    van Vliet-Vroegindeweij, Corine
    Mans, Anton
    Belderbos, Jose S.
    Damen, Eugene M. F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1560 - 1567