Diagnostic Accuracy of Echo-planar Diffusion-weighted Imaging in the Diagnosis of Intra-cerebral Abscess by Taking Histopathological Findings as the Gold Standard

被引:5
|
作者
Siddiqui, Hina [1 ]
Vakil, Sameera [1 ]
Hassan, Maria [2 ]
机构
[1] DUHS, Radiol, Karachi, Pakistan
[2] Dr Ziauddin Hosp, Radiol, Karachi, Pakistan
关键词
intra-cerebral abscess; echo-planar diffusion-weighted imaging; BRAIN-ABSCESS; COEFFICIENT; TUMORS;
D O I
10.7759/cureus.4677
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine the diagnostic accuracy of echo-planar diffusion-weighted imaging (DWI) in the diagnosis of intra-cerebral abscesses by taking histopathological findings as the gold standard. Subject and methods A retrospective cross-sectional study was performed from July 2014 to June 2015 at a tertiary care hospital in Karachi. A total of 462 patients, who were referred for magnetic resonance imaging (MRI) brain, presenting with clinical suspicion of an intra-cerebral abscess on the basis of clinical signs and symptoms, were included in this study. MR imaging was performed. All patients subsequently underwent surgery. The histopathological findings of these patients were collected and compared with echo-planar diffusion-weighted MRI findings. A proforma was used to record the findings. Results The mean age of the patients was 47.39 +/- 13.54 years. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of echo-planar diffusion-weighted MRI in the diagnosis of intra-cerebral abscesses was 85.64%, 95.88%, 93.82%, 90.14%, and 91.56%, respectively. Conclusion Brain abscesses and necrotic tumors are, most of the time, difficult to differentiate on routine conventional imaging, and prompt diagnosis is important, as an untreated brain abscess could be lethal. Diffusion imaging can aid in the diagnosis and further management plan so as to help in improved patient care. Although this sequence has high sensitivity and specificity, it should be used in addition to conventional imaging and not as a replacement of histopathology.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Focal liver masses: Characterization with diffusion-weighted echo-planar MR imaging
    Namimoto, T
    Yamashita, Y
    Sumi, S
    Tang, Y
    Takahashi, M
    [J]. RADIOLOGY, 1997, 204 (03) : 739 - 744
  • [22] Head and neck lesions: Characterization with diffusion-weighted echo-planar MR imaging
    Wang, JC
    Takashima, S
    Takayama, F
    Kawakami, H
    Saito, A
    Matsushita, T
    Momose, M
    Ishiyama, T
    [J]. RADIOLOGY, 2001, 220 (03) : 621 - 630
  • [23] A characteristic feature of acute haematomas in the brain on echo-planar diffusion-weighted imaging
    N. Morita
    M. Harada
    K. Yoneda
    H. Nishitani
    M. Uno
    [J]. Neuroradiology, 2002, 44 : 907 - 911
  • [24] A characteristic feature of acute haematomas in the brain on echo-planar diffusion-weighted imaging
    Morita, N
    Harada, M
    Yoneda, K
    Nishitani, H
    Uno, M
    [J]. NEURORADIOLOGY, 2002, 44 (11) : 907 - 911
  • [25] Moyamoya disease: Evaluation with diffusion-weighted and perfusion echo-planar MR imaging
    Yamada, I
    Himeno, Y
    Nagaoka, I
    Akimoto, H
    Matsushima, Y
    Kuroiwa, T
    Shibuya, H
    [J]. RADIOLOGY, 1999, 212 (02) : 340 - 347
  • [26] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [27] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    [J]. CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [28] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    [J]. ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [29] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    [J]. Abdominal Radiology, 2016, 41 : 100 - 108
  • [30] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918