EVALUATION OF DAMPING ESTIMATES IN THE PRESENCE OF CLOSELY SPACED MODES USING OPERATIONAL MODAL ANALYSIS TECHNIQUES

被引:0
|
作者
Bajric, Anela [1 ]
Brincker, Rune [2 ]
Thons, Sebastian [1 ]
机构
[1] Tech Univ Denmark, Dept Civil Engn, Lyngby, Denmark
[2] Aarhus Univ, Dept Engn, DK-8000 Aarhus C, Denmark
关键词
Operational Modal Analysis; structural damping; Eigensystem Realization Algorithm; Frequency Domain Decomposition; closely spaced modes; IDENTIFICATION;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The Operational Modal Analysis (OMA) techniques provide in most cases reasonably accurate estimates of structural frequencies and mode shapes. They are however known to produce erroneous structural damping estimates, which are presumably thought to be due to inherent random- or bias errors that have varying significance for different techniques. This paper evaluates the sensitivity of damping estimates of closely spaced modes for two existing OMA techniques derived in the time and frequency domain; namely Eigensystem Realization Algorithm (ERA) and Frequency Domain Decomposition (FDD). The evaluation is based on identification using random response from white noise loading of a three degree-of-freedom (3DOF) system numerically established from specified modal parameters for a range of natural frequencies. The numerical model provides comparisons of the effectiveness of damping estimation for a variety of damping levels, signal noise and the sensitivity to closely spaced modes. It is shown that FDD has a tendency to overestimate damping due to leakage in the estimated spectral density function and it is a more sensitive technique to system changes than the ERA. The accuracy of damping estimates converges with increased frequency of the system, which is mainly a result of the problematic regions in the correlation function estimation. These regions cause amplification of the damping estimation errors at higher levels of damping. This emphasizes the importance of correctly estimating the correlation function and spectral density as bias will potentially result in large errors in the estimation of highly damped systems. It is concluded that damping estimated are sensitive to closely spaced modes. In addition, it is found that two closely spaced modes will also disturb the estimation of damping of the remaining modes in the system.
引用
收藏
页码:421 / 433
页数:13
相关论文
共 50 条
  • [41] OPERATIONAL MODAL ANALYSIS OF TORSIONAL MODES IN ROTATING MACHINERY
    Carden, Eoin Peter
    Lindblad, Mattias
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 7A, 2014,
  • [42] Structural response reconstruction for non-proportionally damped systems in the presence of closely spaced modes
    Wan, Zhimin
    Wang, Ting
    Huang, Qibai
    Li, Lin
    JOURNAL OF VIBROENGINEERING, 2014, 16 (08) : 3740 - 3758
  • [43] Determination of rolling tyre modal parameters using Finite Element techniques and Operational Modal Analysis
    Palanivelu, Sakthivel
    Rao, Narasimha K., V
    Ramarathnam, Krishna Kumar
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2015, 64-65 : 385 - 402
  • [44] Parameters identification of closely spaced modes with the covariance-drivern stochastic subspace and damping ratio dispersion method
    Zhang, Xiaoli
    Xia, Yong
    JOURNAL OF VIBRATION AND CONTROL, 2023, 30 (15-16) : 3596 - 3609
  • [45] A review of operational modal analysis techniques for in-service modal identification
    Fahad Bin Zahid
    Zhi Chao Ong
    Shin Yee Khoo
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2020, 42
  • [46] A review of operational modal analysis techniques for in-service modal identification
    Bin Zahid, Fahad
    Ong, Zhi Chao
    Khoo, Shin Yee
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2020, 42 (08)
  • [47] Virtual Structural Monitoring of Wind Turbines Using Operational Modal Analysis Techniques
    Di Lorenzo, Emilio
    Manzato, Simone
    Peeters, Bart
    Van der Auweraer, Herman
    DAMAGE ASSESSMENT OF STRUCTURES X, PTS 1 AND 2, 2013, 569-570 : 523 - 530
  • [48] Separation of structural modes and harmonic frequencies in Operational Modal Analysis using random decrement
    Modak, S. V.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2013, 41 (1-2) : 366 - 379
  • [49] Operational Modal Analysis in the Presence of Harmonic Excitations: A Review
    Motte, Kenny
    Weijtjens, Wout
    Devriendt, Christof
    Guillaume, Patrick
    DYNAMICS OF CIVIL STRUCTURES, VOL 2, 2015, : 379 - 395
  • [50] Influence of Noise in Correlation Function Estimates for Operational Modal Analysis
    Orlowitz, Esben
    Brandt, Anders
    TOPICS IN MODAL ANALYSIS & TESTING, VOL 9, 2019, : 55 - 64