Three-Year Follow-Up with the Bone Conduction Implant

被引:2
|
作者
Persson, Ann-Charlotte [1 ,3 ]
Reinfeldt, Sabine [2 ]
Hakansson, Bo [2 ]
Rigato, Cristina [2 ]
Jansson, Karl-Johan Freden [2 ]
Eeg-Olofsson, Mans [3 ]
机构
[1] Habilitat & Hlth Hearing Org, Sodra Gubberogatan 6, SE-41663 Gothenburg, Region Vastra G, Sweden
[2] Chalmers Univ Technol, Dept Elect Engn, Gothenburg, Sweden
[3] Univ Gothenburg, Sahlgrenska Acad, Inst Clin Sci, Dept Otorhinolaryngol Head & Neck Surg, Gothenburg, Sweden
关键词
Hearing aids; Questionnaires; Bone conduction; Implanted transducer; Transcutaneous device; INTERNATIONAL OUTCOME INVENTORY; AIDS IOI-HA; DEVICE; SOUND;
D O I
10.1159/000506588
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Background:The bone conduction implant (BCI) is an active transcutaneous bone conduction device where the transducer has direct contact to the bone, and the skin is intact. Sixteen patients have been implanted with the BCI with a planned follow-up of 5 years. This study reports on hearing, quality of life, and objective measures up to 36 months of follow-up in 10 patients.Method:Repeated measures were performed at fitting and after 1, 3, 6, 12, and 36 months including sound field warble tone thresholds, speech recognition thresholds in quiet, speech recognition score in noise, and speech-to-noise thresholds for 50% correct words with adaptive noise. Three quality of life questionnaires were used to capture the benefit from the intervention, appreciation from different listening situations, and the ability to interact with other people when using the BCI. The results were compared to the unaided situation and a Ponto Pro Power on a soft band. The implant functionality was measured by nasal sound pressure, and the retention force from the audio processor against the skin was measured using a specially designed audio processor and a force gauge.Results:Audiometry and quality of life questionnaires using the BCI or the Ponto Pro Power on a soft band were significantly improved compared to the unaided situation and the results were statistically supported. There was generally no significant difference between the two devices. The nasal sound pressure remained stable over the study period and the force on the skin from the audio processor was 0.71 +/- 0.22 N (mean +/- 1 SD).Conclusion:The BCI improves the hearing ability for tones and speech perception in quiet and in noise for the indicated patients. The results are stable over a 3-year period, and the patients subjectively report a beneficial experience from using the BCI. The transducer performance and contact to the bone is unchanged over time, and the skin area under the audio processor remains without complications during the 3-year follow-up.
引用
下载
收藏
页码:263 / 275
页数:13
相关论文
共 50 条
  • [41] Three-Year Follow-up of the Tube Versus Trabeculectomy Study
    Garudadri, Chandra Sekhar
    Rao, Harsha L.
    Senthil, Sirisha
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 149 (04) : 685 - 686
  • [42] Long-term follow-up and review of the Bone Conduction Implant
    Reinfeldt, Sabine
    Eeg-Olofsson, Mans
    Jansson, Karl -Johan Freden
    Persson, Ann -Charlotte
    Hakansson, Bo
    HEARING RESEARCH, 2022, 421
  • [43] A Retrospective Comparison of Trabeculectomy, Baerveldt Glaucoma Implant, and Microinvasive Glaucoma Surgeries in a Three-Year Follow-Up
    Nuzzi, Raffaele
    Gremmo, Giulia
    Toja, Francesca
    Marolo, Paola
    SEMINARS IN OPHTHALMOLOGY, 2021, 36 (08) : 839 - 849
  • [44] The outcomes of navigation-assisted bone tumour surgery MINIMUM THREE-YEAR FOLLOW-UP
    Cho, H. S.
    Oh, J. H.
    Han, I.
    Kim, H-S.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (10): : 1414 - 1420
  • [45] Successful haploidentical bone marrow transplantation in a patient with reticular dysgenesis: Three-year follow-up
    Heltzer, Meredith Lee
    Paessler, Michele
    Raffini, Leslie
    Bunin, Nancy
    Perez, Elena Elizabeth
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 120 (04) : 950 - 952
  • [46] FATIGUE IN ADULTS WITH CEREBRAL PALSY: A THREE-YEAR FOLLOW-UP STUDY
    Oude Lansink, Irene L. B.
    McPhee, Patrick G.
    Brunton, Laura K.
    Gorter, Jan Willem
    JOURNAL OF REHABILITATION MEDICINE, 2018, 50 (10) : 886 - 891
  • [47] Three-year follow-up study of allergy in workers in a mushroom factory
    Tanaka, H
    Saikai, T
    Sugawara, H
    Tsunematsu, K
    Takeya, I
    Koba, H
    Matsuura, A
    Imai, K
    Abe, S
    RESPIRATORY MEDICINE, 2001, 95 (12) : 943 - 948
  • [48] Laparoscopic cryoablation for small renal masses: Three-year follow-up
    Weld, Kyle J.
    Figenshau, Robert S.
    Venkatesh, Ramakrishna
    Bhayani, Sam B.
    Ames, Caroline D.
    Clayman, Ralph V.
    Landman, Jaime
    UROLOGY, 2007, 69 (03) : 448 - 451
  • [49] Three-Year Clinical and Radiographic Implant Follow-up in Sinus-Lifted Maxilla With Lateral Window Technique
    Erdem, Necip Fazil
    Ciftci, Alanur
    Acar, Ahmet Huseyin
    IMPLANT DENTISTRY, 2016, 25 (02) : 214 - 221
  • [50] Three-year follow-up of drug abuse resistance education (DARE)
    Dukes, RL
    Ullman, JB
    Stein, JA
    EVALUATION REVIEW, 1996, 20 (01) : 49 - 66