Evaluation of a newly developed HIV antigen test

被引:0
|
作者
Fransen, K [1 ]
Mertens, G [1 ]
Stynen, D [1 ]
Goris, A [1 ]
Nys, P [1 ]
Nkengasong, J [1 ]
Heyndrickx, L [1 ]
Janssens, W [1 ]
vanderGroen, G [1 ]
机构
[1] INNOGENET NV,ZWIJNDRECHT,BELGIUM
关键词
p24; antigen; HIV; antigen detection;
D O I
10.1002/(SICI)1096-9071(199709)53:1<31::AID-JMV6>3.0.CO;2-R
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
A new monoclonal antibody-based enzyme immunoassay (Innogenetics) for the detection and quantification of p24 core antigens of HIV-1 (group M and group O) and of HIV-2 was evaluated on 2745 serum samples and 18 culture supernatants and compared with a reference (Coulter) HIV-1 p24 antigen assay. Positive results were confirmed by neutralization with the reagents of the respective tests. As demonstrated by dilution series of HIV cocultures, the new test recognizes p24 antigen of the most common HIV genetic subtypes, including group O and HIV-2. Titres ranged from 729 to 531441. Therefore p24 antigen assay is but very weakly reactive with HIV-2 (titres from 9 to 81). The new test is considerably more sensitive than the reference. In a population of 365 followup samples from 86 different patients, representing all stages of infection, the new test detected p24 antigen at least once in 52% (45/86) of these patients, whereas the reference was positive in 31% (27/86). The newly designed test detected antigen in 40% (145/365) of the samples, while the reference was positive in 21% (75/365). In a group of PCR and/or culture positive neonates, 33% (9/27) of the samples were positive with the new test versus 18% (5/27) with the reference. The specificity of the new test, as determined on 2,000 blood donor samples, was 99.65% (initially), 99.80% (after repetition), and 100% (with neutralization). The reference scored 99.95%, 100%, and 100%, respectively. In 300 seronegative samples from persons at risk, the initial specificity of the new test was 98.67% (the reference, 99.00%). With neutralization, both assays were 100% specific. (C) 1997 Wiley-Liss, Inc.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [21] A newly developed test rig for the study of thermal fatigue
    Fazarinc, M.
    Turk, R.
    Kugler, G.
    Tercelj, M.
    [J]. COMPUTATIONAL METHODS AND EXPERIMENTAL MEASUREMENTS XIII, 2007, 46 : 45 - +
  • [22] Safety evaluation of newly developed carbamate insecticides
    Jiang, Ying
    Ekstrom, Fredrik
    Carlier, Paul R.
    Hartsell, Josh
    Ma, Ming
    Bloomquist, Jeffrey R.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 238 : 541 - 541
  • [23] THE HIV ANTIGEN NEUTRALIZATION TEST - A NECESSITY
    DAVIS, C
    MINNEMAN, JL
    HOLLADAY, MK
    WERNER, A
    [J]. TRANSFUSION, 1987, 27 (06) : 519 - 519
  • [24] Simulation of advanced cataract surgery - validation of a newly developed test
    Jacobsen, Mads Forslund
    Konge, Lars
    Cour, Morten la
    Holm, Lars
    Kjaerbo, Hadi
    Moldow, Birgitte
    Saleh, George M.
    Thomsen, Ann Sofia Skou
    [J]. ACTA OPHTHALMOLOGICA, 2020, 98 (07) : 687 - 692
  • [25] Evidence of Validity for a Newly Developed Digital Cognitive Test Battery
    Vermeent, Stefan
    Dotsch, Ron
    Schmand, Ben
    Klaming, Laura
    Miller, Justin B.
    van Elswijk, Gijs
    [J]. FRONTIERS IN PSYCHOLOGY, 2020, 11
  • [26] Newly developed rapid loading test method for small piles
    Kunimatsu, S.
    Umeda, M.
    Murakami, H.
    Sakai, T.
    [J]. APPLICATION OF STRESS-WAVE THEORY TO PILES: SCIENCE, TECHNOLOGY AND PRACTICE, 2008, : 497 - 500
  • [27] Natural product synthesis as a challenging test of newly developed methodology
    Donohoe, Timothy J.
    Pullin, Robert D. C.
    [J]. CHEMICAL COMMUNICATIONS, 2012, 48 (98) : 11924 - 11938
  • [28] RELIABILITY AND VALIDITY OF A NEWLY DEVELOPED TEST OF PHYSICAL WORK PERFORMANCE
    LECHNER, DE
    JACKSON, JR
    ROTH, DL
    STRAATON, KV
    [J]. JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1994, 36 (09) : 997 - 1005
  • [29] A wind tunnel test of newly developed personal bioaerosol samplers
    Su, Wei-Chung
    Tolchinsky, Alexander D.
    Sigaev, Vladimir I.
    Cheng, Yung Sung
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2012, 62 (07) : 828 - 837
  • [30] Newly Developed Test Pile Intended to Improve Pile Design
    Jones, Jenny
    [J]. CIVIL ENGINEERING, 2011, 81 (06): : 42 - 43